Laserfiche WebLink
" o <br /> Environmental Health DepartmentSAN JOAQUIN <br /> COUNTY Jas it Kang , REHS , Director <br /> jjrMuniappa Naidu , REHS , Assistant Director <br /> cGreatness grows here .R <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> July 14 , 2021 <br /> MARTY WEITHMAN <br /> SERVICE STATION SYSTEMS , INC . <br /> 680 QUINN AVE <br /> SAN JOSE , CA 95112 <br /> SR0083859 <br /> Re : ATS MINI MART INC <br /> 7906 N EL DORADO ST <br /> STOCKTON , CA 95210 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of <br /> the application for a permit for the following repairs on the underground storage tank ( UST) system <br /> at the above noted address : <br /> Replace (4 ) dispensers with conversion frames installation <br /> - Install new software on the monitoring panel with possible cold start <br /> - Convert 91 - product UST to diesel UST <br /> Convert 89 - product UST to 91 - product UST <br /> Replace the automatic tank gauge (ATG ) used for overfill on the converted diesel tank <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District <br /> for any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones . <br /> 3 . Provide written notification to usfi slgov . orq to arrange the following appointments ( a 48- <br /> hour notice is required for inspection appointments ) . <br /> a . Sensor functionality : Functionality of the monitoring system must be verified to <br /> ensure that monitoring has been restored to meet the requirements of Title 23 <br /> California Code of Regulations and the Health & Safety Code . A copy of the alarm <br /> history shall be printed prior to performing the " cold start" of the monitoring system <br /> and made available at the time of EHD inspection . <br /> b . Overfill prevention verification : Verify that external audible/visual alarm activates <br /> when tank is 90 % full . <br /> c . Verification of the dispenser footprints contained by the under dispenser containment <br /> sumps ( UDCs) <br /> d . Visual inspection of the piping within the dispensers for any leaks . <br /> e . Provide hazardous waste determination and proof of proper disposal for the <br /> generated 91 product tank/piping rinsate <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjgov . org/ehd <br />