Laserfiche WebLink
_ nU1N SAN J O A Q U I N Environmental Health Department <br /> Q' - <br /> COUNTY Jasjit Kang , REHS , Director <br /> Muniappa Naidu, REHS , Assistant Director <br /> gCiFOR? Greatness grows here . <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> October 21 , 2021 <br /> MARTY WEITHMAN <br /> SERVICE STATION SYSTEMS , INC . <br /> 680 QUINN AVE <br /> SAN JOSE , CA 95112 <br /> AMENDED - SR0083859 <br /> Re : ATS MINI MART INC <br /> 7906 N EL DORADO ST <br /> STOCKTON , CA 95210 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit for the following repairs on the underground storage tank ( UST) system at the <br /> above noted address : <br /> Replace (4) dispensers with conversion frames installation ( COMPLETED ) <br /> / Install new software on the monitoring panel with possible cold start ( COMPLETED ) <br /> Convert 87 (east) tank to diesel tank <br /> - Install piping from the new diesel tank to UDC 1 /2 and UDC 5/6 <br /> - Replace the automatic tank gauge (ATG ) used for overfill on the converted diesel tank <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust(cDsjgov . org to arrange the following appointments (a 48 - hour <br /> notice is required for inspection appointments) <br /> a) Primary piping soap test of the 87 and diesel piping and penetrations ( product) : One <br /> hour pneumatic pressure test at 110 % of operating pressure , or 40 psi , whichever is <br /> greater. <br /> b) Secondary piping soap test of the 87 and diesel piping and penetrations ( product) : <br /> One- hour pressure test at the manufacturers recommended specification . <br /> c) Secondary piping slope , at 1 / 8 inch per foot or greater , to a containment sump with an <br /> audible/visual alarm . <br /> d ) Verification of all pipe setbacks and burial depth according to the manufacturer' s <br /> installation Instructions . Verification of appropriate backfill . <br /> e) Since concrete will be broken near the tank , UDCs and 91 piping , a secondary <br /> containment test must be performed in accordance with the manufacturer' s guidelines . <br /> f) Overfill prevention verification : Verify that external audible/visual alarm activates when <br /> diesel tank is 90 % full . <br /> Sensor functionality : Functionality of the monitoring system must be verified to ensure <br /> that monitoring has been restored to meet the requirements of Title 23 California Code <br /> of Regulations and the Health & Safety Code . A copy of the alarm history shall be <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www . sjgov . org/ehd <br />