Laserfiche WebLink
UL/ ULC Listed Red Thread ® IIA Piping System <br /> Lowest Total Cost Ownership <br /> Benefits of [ Material Cost + Installation Cost] _ System Life <br /> 'i Maintenance cost and replacement cost not required with RED THREAD IIA piping system . <br /> Fiberglass Piping Thirty Year Outstanding Corrosion <br /> E <br /> n Underground w a r r a n t y Resistance — RED THREAD IIA <br /> — With over 40 piping systems resist internal and <br /> Fuel Applications years proven external corrosion from hazardous <br /> performance in soils , fuels and other corrosive <br /> TIME TESTED the marketplace , fluids . <br /> Underwriter ' s <br /> • 30- Year Warranty Laboratories , Inc . Quality Assurance — FGS <br /> and Underwriter ' s Laboratories Smith Fibercast quality assurance <br /> Canada ( UL / ULC ) Listed RED procedures meet or exceed the <br /> • Installed since 1964 THREAD IIA pipe , fittings and test requirements of UL/ ULC . <br /> adhesive carry a 30 -year warranty. <br /> • Never been removed due The product is warranted to be Permeability — RED THREAD <br /> to fuel incompatibility free from defects in material and IIA permeability resistance <br /> workmanship —and against internal greatly exceeds UL allowable <br /> • Total immersion testing and external corrosion —when used permeability. <br /> in fuels for underground transportation of <br /> fuels . 2004 UL 971 : <br /> Primary - 1 gm / m2/day <br /> • Case History G7301 Leak Prevention Sump ( 0 . 053 gal/ 100 ft . of 2 " pipe , <br /> — <br /> entry /termination fittings provide 30 days ) <br /> positive seal at the sump to help Secondary - 4 gm / m2/day <br /> LOWEST TOTAL COST prevent leaking of underground ( 0 . 213 gal/ 100 ft . of 2 " pipe , <br /> OF OWNERSHIP fuel in or out of the sump . This 30 days ) <br /> fitting also helps provide Class 1995 UL 971 : <br /> • No reinstall costs due I ( leak prevention ) protection Primary . 4 gm/m2/day <br /> to fuel incompatibility which complies with California ' s ( 0 . 213 gal/ 100 ft . of 2 " pipe , <br /> requirement for continuous 30 days ) 2 <br /> interstitial monitoring of the piping Secondary - 24 gm /m /day <br /> • Homogenous system : no ( 1 . 278 gal/ 100 ft . of 2 " pi <br /> systems secondary containment . pe , <br /> liner, no bladder 30 days ) <br /> • Exceptional Flow <br /> ATRUE PIPE INAPIPE Characteristics - Two - inch <br /> RED THREAD IIA pipe has the <br /> • Interstitial space largest I . D . ( 2 . 235 " ) in the fueling ` - - <br /> communication industry—allowing you to sell twice ` <br /> the fuel per foot than any 11 /2 " <br /> • Leak prevention , not flexible product on the market . <br /> Three - inch RED THREAD IIA <br /> leak detection Old vs New - Pipe in the foreground was <br /> fiberglass pipe has a nominal 3 . 36 " installed in 1973 and removed 27 years <br /> • INSTALL IT, BURY IT, 1 . D . ; four- inch pipe has a 4 . 36 " I . D . later when the station closed. <br /> FORGET IT! <br /> * Please review FGS Smith Fibercast's written warranty to determine the terms and conditions . <br /> 2 <br />