Laserfiche WebLink
MATERIAL SPECIFICATIONS EXHAUST FAN AND MAKE-UP AIR FAN SCHEDULE ABBREVIATIONS MECHANICAL GENERAL NOTES <br /> MARK MANUFACTURER/ ELEC.MOTOR REQT'S OP.WT. LU U Lo E <br /> 1. ALL MATERIALS SHALL HAVE A MINIMUM PERFORMANCE TEMPERATURE N0. MODEL NUMBER TYPE CFM SONES S.P. WATTS AMPS VOLT PH LBS. DESCRIPTIONS ABBR. DISCRIPTION ABBR. DISCRIPTION ABBR. DISCRIPTION 1. SCOPE: FURNISH AND INSTALL COMPLETE AND OPERATING HVAC SYSTEMS. INCLUDING, BUT }, 00C 00 O T <br /> RATING PER UL-181 (DUCTS), UL-181 (CLOSURE SYSTEMS FOR RIGID NOT LIMITED TO, AIR CONDITIONING UNITS, FORCED AIR UNITS, AIR HANDLERS, HEAT PUMPS, > C <br /> CAPTIVE-AIRE 900 --- 1.0" 0.5 HP INCLUDE ROOF CURB,DUCT TRANSITION PIECES 0, DIA. DIAMETER (E) EXISTING OADB OUTSIDE AIR DRY DX COILS, DUCTS, DAMPERS, GRILLES, CONTROLS AND REFRIGERANT LINES ETC., AS � CID N N � O � <br /> FIBERGLASS DUCTS) UL-181B-FX(CLOSURE SYSTEMS FOR FLEXIBLE DUCTS) EF-1 KITCHEN HOOD EXHAUST FAN 6.3 FLA 115 1 82 # POUND/NUMBER EA EACH BULB <br /> AND/OR UL-181 BM(MASTIC); BUTYL BACKED TAPE MAY ALSO BE USED TO DU50HFA --- --- --- --- GENERALLY DELINEATED ON THE MECHANICAL DRAWINGS. Cn N N ODA- E O <br /> SEAL DUCT, DUCTBOARD AND METAL DUCTS. & AND EDB ENTERING DRY BULB OBD OPPOSED BLADE M - +� <br /> CEILING MOUNTED 80 0.3 0.10" 7.6 BACKDRAFT DAMPER,CEILING GRILLE,4"DUCT SIZE, LU <br /> O M -� O <br /> EF-2 BROAN XB80 0.3 120 1 12.5 @ AT EER ENERGY EFFICIENCY DAMPER f0 , T <br /> DIRECT DRIVE 80 0.25" --- OCCUPANCY SENSOR % PERCENT RATIO OC ON CENTER 2. CODES: ALL WORK, MATERIAL AND EQUIPMENT SHALL BE FURNISHED AND INSTALLED IN LL V p) _ +, <br /> 2. CLOTH BACKED, RUBBER ADHESIVE TAPES(TYPICAL DUCT TAPE)SHALL NOT COMPLIANCE WITH THE FOLLOWING CODES AS ADOPTED AND AMENDED BY THE INSPECTING CU >, 7 L <br /> FRIGIKING EVAP.COOLER 810 --- 0.5" 0.33 HP INCLUDE ROOF CURB,DUCT TRANSITION PIECES AP PRESSURE EF EXHAUST FAN OH OVERHEAD J O 0 N U O O O <br /> BE USED EVEN IF UL-181 RATED. MAU-1 KITCHEN HOOD MAKE-UP FAN 7.2 FLA 115 1 175 AUTHORITY HAVING JURISDICTION. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT fA <br /> 350FD ___ ___ ___ ___ DIFFERENTIAL ELEC ELECTRIC OP OPERATING Z <br /> AT TEMPERATURE EQ EQUAL OSA OUTSIDE(FRESH)AIR <br /> THE INSTALLATION OF WORK, MATERIAL OR EQUIPMENT NOT CONFORMING TO THESE OR OTHER Q <br /> � N 3: w <br /> x �• <br /> 3. ALL MATERIALS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF NO CODES APPLICABLE TO THE PROJECT: Z (6 Q coC6 3: �O -1dDIFFERENTIAL EWB ENTERING WET BULB Z }, LL <br /> MORE THAN 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF 50. A. 2016 CALIFORNIA BUILDING CODE- TITLE 24 PART 2 CCR C 06 <br /> °F DEGREE OF EXH EXHAUST P.O.C. POINT OF C <br /> FAHRENHEIT EXH A EXHAUST AIR CONNECTION � 0 <br /> B. 2016 CALIFORNIA ELECTRICAL CODE- TITLE 24 PART 3 CCR O �, - L c <br /> •- <br /> 4. ALL FACTORY FABRICATED DUCT SYSTEMS SHALL INCLUDE UL-181 LISTED C. 2016 CALIFORNIA MECHANICAL CODE- TITLE 24 PART 4, CCR - .? <br /> �/PH PHASE(ELECTRICAL) EXH DCT EXHAUST AIR DUCT PBD PARALLEL BLADE LL N J N w J <br /> DUCTS WITH APPROVED CLOSURE SYSTEMS INCLUDING BUT NOT LIMITED TO ± PLUS OR MINUS DAMPER D. 2016 CALIFORNIA PLUMBING CODE- TITLE 24 PART 5, CCR CID O <br /> COLLARS, CONNECTIONS,&SPLICES. F FURNACE E. 2016 CALIFORNIA FIRE CODE- TITLE 24 PART 9, CCR JLJL O� E > - .� <br /> APACCESS PANEL FAU FORCED AIR UNIT PH PHASE F. 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE- TITLE 24 PART I1, CCR Q D <br /> 06 <br /> . . <br /> 5. ALL PRESSURE SENSITIVE&HEAT ACTIVATED TAPES USED IN THE G. 2016 EDITION OF TITLE 24 TITLE 24 CALIFORNIA CODE OF REGULATIONS O = C ,.2 <br /> ABV ABOVE F/CC FURNACE&COIL PSF POUNDS per Sq. Ft. U - L .- <br /> MANUFACTURE OF RIGID FIBERGLASS DUCTS SHALL BE UL-181A LISTED. H. 2016 CALIFORNIA ENERGY CODE C O .? <br /> AD AUTOMATIC DAMPER FLX DCT FLEX DUCT PSI POUNDS per Sq. In. +, O <br /> ADJ ADJUSTABLE FJ FLOOR JOIST L VENTILATION REQUIREMENT PER ASHRAE STD. 62.1-2016 �� v J (-) -a <br /> 6. ALL PRESSURE SENSITIVE TAPES AND MASTICS USED IN THE MANUFACTURE Z Q ( O > <br /> 26 GAUGE FLEXIBLE DUCT MAY BE USED AND INSTALLED PER CMC APPENDIX A PART B. AFF ABOVE FINISH FLOOR FLR FLOOR REQ'D REQUIRED 0 0 <br /> OF FLEXIBLE DUCTS SHALL BE UL-1816-FX(TAPE)OR UL-181BM (MASTIC) AFG ABOVE FINISH GRADE FOW FACE OF WALL RL REFRIGERANT LIQUID 3. WORKMANSHIP: ALL WORKMANSHIP SHALL BE DONE INA NEAT WORKMANLIKE MANNER E o L O -O <br /> LISTED. DUCTS TO BE ROUTED&SIZED AS SHOWN ON THE VENTILATION PLAN. AFUE ANNUAL FUEL FPM FEET PER MINUTE RPM REVOLUTIONS PER ACCORDING TO THE BEST TRADE PRACTICES BY THOSE SKILLED IN THAT PARTICULAR TRADE. O 0 ti O 0 ,O O <br /> UTILIZATION FT FOOT MINUTE EQUIPMENT, DUCTS, GRILLES ETC., SHALL BE PLUMB, LEVEL, SQUARE OR CENTERED ETC., TO V • 00 � <br /> 7. FACTORY MADE DUCT FOR FIELD-FABRICATED DUCT SYSTEMS SHALL BE PROVIDE APPROPRIATE SCREENED TERMINATION CAP, BACKDRAFT DAMPER AND SWITCHING(PER UTILITY PLAN). PROVIDE A NEAT AND PLEASING APPEARANCE. ALL E UIPMENT SHALL BE INSTALLED IN STRICT O > N N � O <br /> EFFICIENCY FT'G FOOTING RS REFRIGERANT Q LL CV ' (n U c <br /> UL-181 LISTED. COMPLIANCE WITH THE PARTICULAR MANUFACTURER'S RECOMMENDATIONS. AND CONFORM 0c) L T o <br /> FANS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AS DEFINED IN THE MANUFACTURER'S PRODUCT INSTALLATION AHU AIR HANDLING UNIT SUCTION O o M 00 <br /> DOCUMENTATION. ALT ALTERNATE GA GAUGE RET RETURN WITHACCA/ANSI STANDARD 5 QI SPECIFICATION Z }, � M 0 -0 a> <br /> 8. SEALANTS SHALL BE UL-181BM LISTED, NON-TOXIC AND WATER RESISTANT. J � \ c E <br /> GALV GALVANIZED 'RA RETURN AIR Q Q � -0 -0 a) O <br /> SEE INDIVIDUAL MECHANICAL PLANS FOR EXHAUST FAN DUCT SIZES. BD BAROMETRIC GPM GALLON PER MINUTE RAD RETURN AIR DUCT 4. AVAILABLE POWER: THE HVAC CONTRACTOR SHALL CONFIRM ALL SYSTEM VOLTAGES BEFORE �p cO 41 0 <br /> 9. SEALANTS FOR INTERIOR APPLICATIONS SHALL PASS THE ASTM TESTS C-731 N CD O v 'L N <br /> DAMPER RGD DCT RIGID DUCT BIDDING OR ORDERING EQUIPMENT AND ALLOW FOR BUCK&a BOOST TRANSFORMERS IF O0 <br /> (EXTRUDABILITY AFTER AGING)&D-2202(SLUMP TEST ON VERTICAL BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING PER 2013 CGBC SECTION 4.506. B <br /> DD BACKDRAFT DAMPER HOR HORIZONTAL REQUIRED. Q a) o <br /> SURFACES). 0 N E L -c CO <br /> UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, BATHROOM EXHAUST FANS MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE BEL BELOW HP HORSE POWER SMSHEET SHEET METAL 0) .- Q � al <br /> BLK'G BLOCKING HSPF HEATING SEASONAL SD SMOKE DETECTOR 5. DUCT SIZING&a AIR BALANCE: THE AIR DISTRIBUTION SYSTEM(DUCTWORK&a DEVICES)HAS uj73 <br /> 10. SEALANTS AND MESHES SHALL BE RATED FOR EXTERIOR USE. READILY ACCESSIBLE. HUMIDISTAT CONTROLS SHALL BE CAPABLE OF ADJUSMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 80 PERCENT PER 2016 CGBC SECTIONLL m co c <br /> 4.506. BOT BOTTOM PERFORMANCE SEER SEASONAL ENERGY BEEN SIZED&s BALANCED TO DELIVER THE SPECIFIED AIR QUANTITIES AS NOTED ON THE �� c <br /> BTUH BRITISH THERMAL FACTOR EFFICIENCY RATIO PLANS, FOLLOWING THE PROCEDURES &REQUIREMENTS OF THE LATEST EDITION OF THE ACCA C/3N p O 'un O_ L <br /> 11. SEALANTS FOR EXTERIOR APPLICATIONS SHALL PASS ASTM TESTS C-731, THE ABOVE FANS HAVE BEEN SPECIFIED TO MEET THE MINIMUM REQUIREMENTS.AN ALTERNATE FAN THAT MEETS OR EXCEEDS THE ABOVE SPECIFICATIONS MAY BE UNITS HTG HEATING SENS SENSIBLE MANUAL "J"&s MANUAL "D". BALANCING SHALL BE PER PROCEDURAL STANDARDS FOR TESTING, ZO U - -O <br /> C-732(ARTIFICIAL WEATHER TESTING),AND D-202. p <br /> INSTALLED&VERIFIED WITH A CF-6R FORM. SQ SQUARE BALANCING&a ADJUSTING ENVIRONMENTAL AIR SYSTEMS. THE CONTRACTOR SHALL PROVIDE <br /> 12. ALL TAPE USED FOR FLEXIBLE DUCT CONNECTIONS SHALL BE UL-181B-FX CC COOLING COIL IAEWB INDOOR AIR STD STANDARD ACCESSIBLE&i ADJUSTABLE VOLUME DAMPERS(SHOWN OR NOT)AS REQUIRED TO BALANCE U <br /> LISTED OR BE ALUMINUM-BACKED BUTYL ADHESIVE TAPE(15 MIL MINIMUM CD CONDENSING DRAIN ENTERING WET BULD Sq In SQUARE INCH THE SYSTEMS AND MAINTAIN NOISE CRITERIA LEVEL NOT TO EXCEED 25-30. CONTRACTOR TO <br /> THICKNESS). CEF CEILING EXHAUST IN. INCH SPLY SUPPLY ENSURE SYSTEM IS BALANCED. <br /> AIR DISTRIBUTION DEVICE SCHEDULE FAN L STEEL SA SUPPLY AIR <br /> 13. TAPE USED FOR DUCTBOARD SHALL BE UL-181A LISTED AND SO INDICATED CSF CEILING SUPPLY FAN LBPOUNDS POUNDS SAD SUPPLY AIR DUCT 6. EXISTING INFORMATION: LOCATION, SIZE, MATERIAL ETC., OF EXISTING SYSTEMS, STAMP. <br /> WITH A UL-181A MARKING OR BE ALUMINUM BACKED BUTYL ADHESIVE TAPE CFM CUBIC FEET PER STRUCTURES, COMPONENTS, PIPING, ETC., IS DEEMED TO BE RELIABLE BUT IS NOT <br /> MANUFATURER& APPLICATION& BLOW MSDI NECK MINUTE MSD MULTI-SHUTTER T, GUARANTEED. THE CONTRACTOR SHALL FIELD VERIFY ALL DATA BEFORE PROCEEDING WITH <br /> (15 MIL MIN.THICK). MK.N0. MODEL NO. TYPE PATTERN PBD SIZE REMARKS CHK VLV CHECK VALVE DAMPER T-STAT THERMOSTAT ANY WORK. NO EXTRA COST SHALL BE ALLOWED FOR CONDITIONS NOT AS SHOWN. <br /> 14. DRAWBANDS SHALL BE EITHER STAINLESS STEEL WORM DRIVE HOSE CLAMPS CLG CEILING MAX MAXIMUM TCP TEMPERATURE O <br /> F ESS/0 <br /> CD-1 METALAIRE 3000 ROUND CEILING DIFFUSER RADIAL YES SEE PLANS ALUMINUM ROUND DIFFUSER,ROUND NECK,D-3 DAMPER CONC CONCRETE MBH BTUH/1,000 CONTROL PANEL 7. ACCURACY. PLANS ARE DIAGRAMMATIC. THE POSITION/LOCATION OF EQUIPMENT, REGISTERS, Q <br /> OR UV RESISTANT NYLON DUCT TIES.ALL DRAWBANDS SHALL HAVE A F2 <br /> CONT CONTINUOUS MCA MINIMUM CIRCUIT TDR TIME DELAY RELAY GRILLES, DUCTS ETC., SHOWN ON PLANS ARE APPROXIMATE AND MAY BE SHOWN AS IS FOR t�4 pNY AM <br /> MINIMUM TENSILE STRENGTH RATING OF 150 LBS&A MINIMUM PERFORMANCE CD-2 METALAIRE 5700 24"x 24"CEILING DIFFUSER 4-WAY YES SEE PLANS SURFACE-MOUNT,ROUND NECK,RADIAL SHUTTER DAMPER COP COEFFICIENT OF AMPACITY THK THICK CLARITY PURPOSES. ACTUAL LOCATIONS FOR EQUIPMENT SHALL TAKE INTO CONSIDERATION <br /> TEMPERATURE RATING OF 165 DEGREES FAHRENHEIT(CONTINUOUS PER PERFORMANCE MD MANUAL DAMPER TYP TYPICAL ACCESSIBILITY, SERVICE REQUIREMENTS, LOCATION OF TRUSSES AND JOISTS, ETC. THE <br /> UL-181A TYPE TEST).ALL DRAWBANDS SHALL BE TIGHTENED AS CD-3 METALAIRE 5700 12"x 12"CEILING DIFFUSER 4-WAY YES SEE PLANS SURFACE-MOUNT,ROUND NECK,RADIAL SHUTTER DAMPER JM 39333 <br /> RECOMMENDED BY THE MANUFACTURER WITH AN ADJUSTABLE TENSIONING CTG CEILING TRANSFER MIN MINIMUM CONTRACTOR SHALL CONFIRM ALL DIMENSIONS,LOCATIONS & CLEARANCES OF AC UNITS, <br /> CR-1 METALAIRE CC5-6 CEILING RETURN GRILLE NO SEE PLANS LAY-IN,CUBE CORE,PROVIDE BOOT FOR ROUND DUCT CONNECTION GRILLE MOCP MAXIMUM OVER LINO UNLESS OTHERWISE FURNACES,AIR HANDLERS, EQUIPMENT, FANS, WALLS, PARTITIONS, BEAMS, TRUSSES ETC., <br /> TOOL. CU CONDENSING UNIT CURRENT NOTED AGAINST ARCHITECTURAL&a STRUCTURAL DESIGN PLANS FOR LOCATION CONSISTENCY&a <br /> CR-2 METALAIRE CC5-1 SIDE-WALL RETURN GRILLE --- NO SEE PLANS SURFACE-MOUNT,CUBE CORE,PROVIDE BOOT FOR ROUND DUCT , <br /> PROTECTION ACCURACY PRIOR TO COMMENCING ANY WORK. IF ACTUAL DUCT FIELD LOCATIONS VARY TO <br /> DG-1 METALAIRE DGDF 12 X 12 DOOR GRILLE ._. NO STEEL RESTROOM DOOR GRILLE,150 CFM EXHAUST FANS D PENNY NAIL VERT VERTICAL SIGNIFICANTLY AFFECT FINAL AIR FLOW, IT IS THE RESPONSIBILITY OF THE MECHANICAL <br /> DBL DOUBLE (N) NEW VTR VENT TO ROOF CONTRACTOR TO CONTACT THE MECHANICAL ENGINEER PRIOR TO INSTALLATION. S� �FCHAN0' <br /> DESIGN/INSTALLATION NOTES DEG DEGREES N/A NOT APPLICABLE VTW VENT TO WALL OFCAI-XF <br /> DET DETAIL N.C. NORMALLY CLOSED 8. COORDINATION WITH OTHER TRADES: THESE PLANS WERE CLOSELY COORDINATED WITH <br /> N.I.M.0 NOT IN MECHANICAL W/ WITH AVAILABLE STRUCTURAL&a ARCHITECTURAL PLANS PROVIDED TO CALIFORNIA LIVING AND <br /> 1. PER CEC-400-2012-004-CMF-REV2 SECTION 150.0(H) 1.A.B.C. BUILDING HEATING, CONTRACT W/O WITHOUT ENERGY AT THE TIME THE DESIGN WAS PERFORMED. SUBSEQUENT CHANGES TO THE <br /> COOLING LOADS AND DUCT DESIGN ARE DETERMINED USING A METHOD N.O. NORMALLY OPEN WH WATER HEATER PROVIDED SPECIFICATIONS OR DRAWINGS MAY ADVERSELY AFFECT THE FEATURES OF THE <br /> BASED ON THE FOLLOW: THE ACCA MANUAL J, D,AND S. NOTES: WT WEIGHT MECHANICAL DESIGN. EVERY REASONABLE ATTEMPT HAS BEEN MADE TO BE CONSISTENT WITH <br /> WTG WALL TRANSFER THE BUILDING STRUCTURAL DESIGNS AND PLANS AND TO FOREWARN THE BUILDER/OWNER OF <br /> 2. THE DUCTWORK HAS BEEN SIZED FOR SPECIFIC CARDINAL ORIENTATION. GRILLE POTENTIAL STRUCTURAL CONFLICTS OR CONSTRAINTS OR MODIFICATIONS REQUIRED. IT IS THE <br /> THEREFORE,THE MANUAL VOLUME DAMPERS AT THE SUPPLY PLENUM 1. THE THROW PATTERN SHALL MATCH THE PLANS.ALTERNATE SIZES OR MANUFACTURERS MAY BE UTILIZED.THE CONTRACTOR SHALL BASE THE OWNER/BUILDER'S RESPONSIBILITY TO PROVIDE FIELD COORDINATION OF THESE PLANS WITH <br /> COLLARS ARE REQUIRED FOR COMFORT BALANCING BASED UPON ALTERNATE SELECTIONS UPON A MAXIMUM PRESSURE DROP OF 0.04 @ DEVICE&A MAXIMUM FACE VELOCITY FOR SUPPLY GRILLES OF 700 FEET XFMR TRANSFORMER FRAMING WALLS ROOFS ETC.,AND OTHER TRADES PRIOR TO CONSTRUCTION. CONTACT THE <br /> ORIENTATION. <br /> PER MINUTE.THE INSTALLING CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF THE SUBSTITUTED DEVICES MANUFACTURER'S ARCHITECT AND/OR THE MECHANICAL ENGINEER IF CONFLICTS ARISE MAKING MODIFICATION <br /> 3. THE SEER, EER AND AFUE RATINGS FOR THE MECHANICAL EQUIPMENT ARE CRITERIA. NECESSARY. SPECIAL CARE MUST BE TAKEN WHEN LAYING OUT FLOOR JOISTS/TRUSSES OR <br /> BASED UPON BEST KNOWLEDGE AVAILABLE FROM THE MANUFACTURER. ROOF JOISTS/TRUSSES AS NOT TO IMPEDE THE UPPER OR LOWER OPENING OF ANY VERTICAL <br /> THEY RESERVE THE RIGHT TO UPDATE, REVISE OR DELETE EQUIPMENT OR 2. ACCEPTABLE ALTERNATE MANUFACTURERS SHALL BE J&J,AIRMATE, HART&COOLEY, LIMA,TRU-AIR. DUCT CHASE. <br /> THE PRINTED EFFICIENCY RATINGS.THE CONTRACTOR SHALL VERIFY ANY <br /> SUBSTITUTION OF COILS OR CONDENSERS SHALL MEET THE MATCHED 3. TG-1 SHALL BE MINIMUM 1 SIZE LARGER THAN JUMP DUCT SIZE(I.E.JUMP DUCT=8"0,TG-1 SHALL BE 10"x10").JUMP DUCT SIZE SHALL BE MINIMUM 1 MECHANICAL LEGEND 9. ENERGY FEATURES: ALL CALCULATIONS AND SPECIFIED EQUIPMENT OR DEVICES ARE <br /> RATINGS AS PROVIDED BY THAT MANUFACTURER. SIZE LARGER THAN SUPPLY DUCT SIZE I.E.SUPPLY DUCT=T-0,JUMP DUCT SHALL BE 8"0) <br /> . <br /> CONSISTENT WITH THE ENERGY CRITERIA 8c FEATURES PROVIDED TO CALIFORNIA LIVING AND <br /> 4. FINAL DUCT AND SUPPLY REGISTER LOCATION MAY BE ADJUSTED BY ENERGY AT THE TIME OF DESIGN. ANY SUBSEQUENT CHANGES TO THE SUPPLIED CRITERIA <br /> MECHANICAL CONTRACTOR WITH APPROVAL OF CLE IN ORDER TO MAINTAIN SYMBOL DESCRIPTION MAY AFFECT FEATURES OF THE DESIGN INCLUDING BUT NOT LIMITED TO EQUIPMENT SIZES, <br /> STRUCTURAL INTEGRITY. DUCT SIZES &v LOCATIONS, OUTLET/INLET DEVICE SIZES&s LOCATIONS ETC. <br /> SUPPLY AIR DUCT � <br /> 5. CL&E IS NOT RESPONSIBLE FOR PROPER SYSTEM PERFORMANCE IF THE 10. EQUIPMENT SIZING AND AIR DISTRIBUTION. THE EQUIPMENT, DUCT SIZING, AND ROOM-TO-ROOM <br /> INSTALLATION DOES NOT CONFORM TO OOUR DESIGN,AND MATCH ALL SIZED - - RETURN AIR DUCT FEW � <br /> COMPONENTS. CFM REFLECTED ON DRAWINGS HAS BEEN SIZED BY ACCA APPROVED MANUAL S, D, AND J. ANY <br /> - - - - - - - EXHAUST DUCT CHANGE IN SIZING FOR EQUIPMENT, DUCTING, DUCT RUN LENGTHS OR INSTALL DEVEIATIONS N <br /> 6. CONTRACTOR MUST CONTACT CL&E WITHIN 24HRS OF ANY FIELD ISSUES WILL NOT BE WARRANTED UNDER CURRENT DESIGN UNLESS APPROVED IN WRITING BY CLEN `� <br /> THAT PREVENT A QUALITY INSTALLATION.CL&E WILL NOT BE RESPONSIBLE OA MAKE-UP AIR/OUTSIDE AIR(OA) PRIOR TO INSTALLATION. .^ m <br /> O <br /> FOR FIELD ISSUE NOT REPORTED WITHIN THIS TIMELINE � <br /> CI] PRIMARY CONDENSATE DRAIN M <br /> 11. EQUIPMENT SUBSTITUTIONS: EQUIPMENT SUBSTITUTION MUST BE APPROVED BY CLE PRIOR TO <br /> SDSECONDARY CONDENSATE DRAIN INSTALLATION AND MUST ACCURATELY DEMONSTRATE EQUIVALENCE OF UNIT CAPACITIES, 06 <br /> OTI AIRFLOW PERFORMANCE BASED UPON DETAILED DESIGN CONDITIONS, INCLUDING BUT NOT O <br /> T THERMOSTAT(T1 =ZONE 1) LIMITED TO: SEER'S, EER'S, HSPF'S, COP'S, AFUE'S, SENSIBLE CAPACITIES(k,DESIGN Uj -I <br /> -IIII CEILING EXHAUST FAN (CEF) CONDITIONS, AIRFLOWS AT DESIGN STATIC PRESSURES, HEATING OUTPUT CAPACITIES, COIL ■� <br /> STATIC PRESSURE DROPS, EQUIVALENT LENGTH OF FITTINGS ETC. ALL EQUIPMENT SHALL BE r � <br /> INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURER'S PRINTED INSTALLATION .^ O <br /> WHOLE HOUSE VENTILATION CEILING EXHAUST FAN (CEF): INSTRUCTIONS. <br /> rl <br /> 1 2!% <br /> • WHOLE HOUSE VENTILATION FAN SHALL BE PER ASHRAE STD. J C362.2-2013. 12. UNDUCTED PLENUMS-PROHIBITED: ALL CAVITIES/SPACES INTENDED TO CONVEY SUPPLY, m <br /> WHOLE HOUSE EXHAUST FAN RETURN OR EXHAUST AIR SHALL BE PROVIDED WITH APPROVED TYPE DUCT BOARD, SHEET �j __ <br /> METAL DUCT, FLEXIBLE DUCT OR OTHER APPROVED MATERIAL FOR THAT SPECIFIC PURPOSE. <br /> PLYWOOD, GYPSUM BOARD, OSB, WOOD/METAL STUDS, ETC. ARE APPROVED MATERIALS. <br /> C - - i EXHAUST DUCT-VENT TO ROOF(VTR) BOXED-IN FRAMING MEMBERS, "PLATFORM RETURNS", PANNED JOISTS AND STUD BAYS AND U <br /> EXHAUST DUCT-VENT TO WALL(VTW) OTHER NON-DUCTED BUILDING CAVITIES ARE PROHIBITED. fFEW ♦ + � <br /> 13. DUCT CHASES, SOFFITS&s DROPPED CEILINGS: SOME CHASES, SOFFITS OR DROPPED CEILINGS co <br /> � <br /> THAT APPEAR ON THE MECHANICAL PLANS MAY NOT APPEAR ON THE ARCHITECTURAL OR D <br /> CEILING SUPPLY FAN (CSF) STRUCTURAL PLANS. CHASES, SOFFITS, AND DROPPED CEILINGS SHALL BE CONSTRUCTED SO <br /> 1 AS NOT TO PINCH, CRIMP, CRUSH OR OTHERWISE OBSTRUCT THE DUCTWORK. A GENERAL RULE <br /> OF THUMB IS TO HAVE AN INSIDE CLEAR CHASE DIMENSION EQUAL TO THAT OF THE DUCT <br /> ®� <br /> SUPPLY AIR DIFFUSER 4-WAY(CS-4) DIAMETER PLUS 2 INCHES(INCLUDING INSULATION THICKNESS IN CALCULATION). ENSURE THAT 06 _j <br /> FLEXIBLE DUCTS TO MAINTAIN A MINIMUM RADIUS OF TURN OR PROVIDE SHEET METAL ELBOWS <br /> 11 AS REQUIRED.t <br /> � <br /> I 14. ENVIRONMENTAL AIR DUCTS:ALL ENVIRONMENTAL AIR DUCTS(CLOTHES DRYER MOISTURE <br /> HANGERS <br /> � <br /> STRAP A V G R R S TO BE C SEE PLANS FOR DUCT SIZE ®� 0 SUPPLY AIR DIFFUSER 3-WAY: CEILING(CS-3), FLOOR(FS-3) GALVANIZED STEEL SHEET METAL DUEXHAUST DUCTS, DOMESTIC KITCHEN CT WITH SMOOTH INTERIOR SURFACES. ALL NGE HOOD DUCTS) SHALL BE ED OF U <br /> CONSTRUCTED RROM E A M E SHALL BE CONSTRUCTED PER CMC CHAPTER 6. <br /> GAUGE GA EV. STEEL AS STAINLESS STEEL ®� SUPPLY AIR DIFFUSER 2-WAY: CEILING(CS-2), FLOOR(FS-2) 0 <br /> C STRAP 15. PIPE INSULATION: THE SUCTION REFRIGERANT LINE FROM THE INDOOR COIL TO THE OUTDOOR O <br /> 40" DUCT - TY P, EVERY R�/ 4 FEET. UNIT(AC OR HEAT PUMP) SHALL BE INSULATED WITH A MINIMUM R-3 INSULATION. INSULATION 0 <br /> 1 111 111 USED FOR REFRIGERANT SUCTION LINES SHALL BE WATER RETARDENT AND PROTECTED FROM <br /> MIN. <br /> /4 91 SUPPLY AIR DIFFUSER 1-WAY: CEILING(CS-1), FLOOR(FS-1),WALL(WS-1) PHYSICAL DAMGE AND UV DETERIORATION PER 2016 CALIFORNIA ENERGY CODE SECTION W <br /> 61 m m p DIA. GAL. 150(J)2B. a_ <br /> 1/2"x10" HOT DIPPED NUT U T CX BOLT ALUMINUM, MFR. BY 1 SUPPLY AIR WALL DIFFUSER 3-WAY(WS-3) 16. DRYER VENTS: 2016 CMC 504.3 ALL INSTALLED DRYER VENTS SHALL MEET (MAX 14', (2) 90° <br /> GALV.LAG BOLTS (N) 20d NAI_, NAILED \ BROAN MODEL 642 <br /> - 3 @ EA, SIDES O RAFT R BELOW �� ELBOWS W/4'�DUCT). <br /> OPEN/CLOSE FLAPPER <br /> UM Q) <br /> (E) PARAPET WALL 17. REFRIGERANT PORT PROTECTION: AIR CONDITIONING REFRIGERANT CIRCUIT ACCESS PORTS <br /> AS BACKDRAFT DAMPER RETURN AIR GRILLE(CR-1) LOCATED OUTDOORS SHALL BE PROTECTED FROM UNAUTHORIZED ACCESS WITH LOCKING TYPE <br /> 4x CURB F1 TAMPER-RESISTANT CAPS OR IN A MANNER APPROVED BY THE AUTHORITY HAVING (� <br /> 5 0 m m W O E DUCT JURISDICTION PER 2016 CMC 1106.14 O <br /> (E) ROOF CTG CTG JUMP DUCT W/CEILING TRANSFER GRILLES(CTG) <br /> (N) 4 x 10 WD.. B M. SAME <br /> A N D G O VST. STEEL <br /> R O M Z_ -Z 18. ALL DUCT OPENINGS AND OTHER RELATED DISTRIBUTION COMPONENT OPENINGS SHALL BE 0 <br /> 5 A M R GAUGE S T E E COVERED DURING CONSTRUCTION PER CALGREEN CODE 4.504.1. REVISIONS / <br /> WTG WALL TRANSFER GRILL(WTG) O <br /> A DUCT WATER TIGHT CAULKING 19. ENVIRONMENTAL AIR EXHAUST DUCTS SHALL TERMINATE A MINIMUM OF X-O'AWAY FROM C) <br /> ALL AROUND LAUNDRY MAKE UP AIR TRANSFER GRILLE OPENINGS INTO THE BUILDING, PER C.M.C. 504.5. AA11/21/19 AA PC Comments <br /> MET. CHANNEL <br /> 20. PROVIE MINIMUN 10'-0"LENGTH OF DUCT AT JUMP DUCTS. Q <br /> J <br /> W/ WASHER MANUAL VOLUME DAMPER - - - <br /> & LOCKNUT 20 GAUGE METAL STRAP <br /> C <br /> w/3/8" DIA. SUPPORT ROD MOTORIZED VOLUME DAMPER - - - - <br /> 00000 1 4x6 D.F. SUB JOIST ON _ _ _ +' <br /> BOTH SIDES W/ U HANGER <br /> 2 ROUND DUCT SUPPORT 1 EXHAUST FAN WALL 45°TEE/90°TEE/45°CROSS/90°CROSS ZN - - - <br /> co <br /> HOOD EXHAUST DUCT: <br /> DOUBLE-WALL GREASE DUCT IN ATTIC PENETRATION ® r 45°WYE/DUCT DROP/DUCT RISER/DUCT CAP - - - U) <br /> CEILING GYP.BD. SEE M0.4 & M0.5 SHEETS L � � <br /> FOR MORE DETAILS SCALE: NONE SCALE: NONE - - - <br /> - - - U <br /> 4 - 1/2" DIA. HOOD X Q ROUND SPIN-IN COLLAR MOUNT <br /> SUPPORTED RODS 11 IN SIDE OF DUCT UNLESS DUCT SEALER AT SPIN <br /> SEE A-4 FOR DETAILS SPECIFICALLY SHOWN OTHERWISE E <br /> COLLAR CONNECTION NO. Date Drn Remarks <br /> TO MAIN Z <br /> 2 ROWS 1/4" SCREWS <br /> @ EA. STUD UPPER ATTACHMENT PER SMACNA SUPPLY DUCT SIZE AS 1 <br /> MAX.4' PER FOOT SHOWN ON PLANS 2 DRAWN: A. Amad io <br /> 6„ <br /> 0 5 3 7 MIN 8 CHECKED: HT <br /> R6 DUCT INSULATION DATE: 11/25/2019 <br /> NOTE: - WHEN IN UNCONDITIONED <br /> CLEARANCE "X" LOCATIONS <br /> LESS THAN 12" SCALE: AS NOTED <br /> REQUIRES CEILING (E)5/8" TYPE "X" SPIRAL SHEET METAL DUCT Q0 <br /> ENCLOSURE PANNEL GYP. BOARD JOB NO: 22471 <br /> 4 <br /> NECK SIZE TO MATCH SHUTTER DAMPER 7 10 SHEET TITLE <br /> FLEX DUCT SIZE INDICATED INSULATE TOP PANEL 0-)OF LAY-IN DIFFUSERCD <br /> 6 MECHANICAL <br /> N <br /> LO <br /> AIR DISTRIBUTION DEVICE, SEE KEYED NOTES NOTES & 1 <br /> REFER TO SHEET MO.2 FOR CEILING (T-BAR SHOWN) SCHEDULE. LAY-IN SHOWN- 1. 3"WIDE ELASTOMETRIC FLASHING 6. PIPE <br /> GYPSUM BOARD SIMILAR STRIP. <br /> ADDITIONAL HOOD DETAILS SURFACE MOUNT SIMILAR 7. PROVIDE FIRE U.L. FC 1 STOPPING MATERIAL DETAILS <br /> 2. GSM PENETRATION FLASHING SET SIMILAR TO . FC 1002 <br /> IN PREHEATED SURFACE. REQUIREMENTS. FILL VOID MIN. %4" ' <br /> HIGH x%"WIDE BEAD OF CAULK � <br /> 3. PROVIDE APP MODIFIED BITUMEN N <br /> STRIP WITH ALUMINUM COATED. 8. PLYWOOD +' <br /> 4. %2"CLEAR. 9. ROOF CAP SHEET 0 <br /> a_ <br /> 5. 3"STAGGERED NAILING. 10. 2 HR. FIRE DAMPER (;RATED CLG <br /> APPLICATIONS(a,STAIRWAYS. N <br /> If a Builder and/or Subcontractor deviates in anyway <br /> from any design produced by California Living & Energy <br /> 4 HOOD INSTALLATION 3"IIIISPIRAL DUCT CONNECTION DETAIL 5 EXHAUST FAN without the expressed written consent of California Living <br /> rI & Energy then all warranties become null and void. For Q) <br /> further clarification refer to clauses & warranties sectionM 001 <br /> DETAILS - TO SUPPLY BOOTS - ROOF PENETRATION of our bid proposal & contract section VI. 0 <br /> SCALE: NONE SCALE: NONE SCALE: NONE <br /> ALL PROJECT DRAWINGS, SPECIFICATIONS AND OTHER WORK PRODUCT PREPARED BY CALIFORNIA LIVING & ENERGY ARE INSTRUMENTS OF SERVICE FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY OF CLE WHETHER THE PROJECT IS COMPLETED OR NOT. ANY REVISIONS, CHANGES, ADAPTATIONS <br /> ETC. TO CL&E's INSTRUMENTS OF SERVICE, ALSO KNOWN AS BUT NOT LIMITED TO DESIGN MUST BE APPROVED IN WRITING BY CLE. REUSE BY CLIENT OF ANY OF CL&E's INSTRUMENTS OF SERVICE FOR ANY PROJECT OTHER THAN THE PROJECT THAT IS THE SUBJECT OF THIS AGREEMENT IS UNAUTHORIZED. <br />