<br /> REVISIONS JLJL ()IfC4 (D 'C
<br /> FAN DESCRIPTION DATE: V O = c_ o
<br /> Q co a,
<br /> FAN BASE PLATE EXHAUST UST FAN INFORMATION — Job 403926
<br /> (LEFT) FAN LU CU a > C) °>
<br /> J 0
<br /> CURB e UNIT TAG FAN UNIT MODEL # CFM ESP. RPM H.P. B.H.P. b VOLT FLA DISCHARGE WEIGHT SONES ELECTRICAL PACKAGE - Job 4039261 J p .� o
<br /> PLATE VELOCITY (LBS.) SWITCHES FANS CONTROLLED C M p L c
<br /> e N 0. NO. TAG PACKAGE # LOCATION OPTION 0 O 0 � O V p
<br /> (LEFT) e eLOCATION QUANTITY FAN TAG TYPE $ H.P. VOLT FLA V 00 -0CO
<br /> 1 KEF-1 DU50HFA 900 1.000 1475 0.500 0.3310 1 115 6.3 342 FPM 82 15.4 - Utility Cabinet 1 Light KEF-1 Exhaust 1 0.500 115 6.3 O N CV (� U o
<br /> 1 SC-11111002 Utility Cabinet Left Smart Controls Basic OC)® D Hood # 1 1 Fan Supply 1 0.333 115 6.0 z Q M >✓ 0 U
<br /> FAN OPTIONS '1 J ��
<br /> ° FAN cjjO Q (� O a) o
<br /> UNIT TAG OPTION Qt - Descr. e Q Q o o a�
<br /> (Qty. >
<br /> JOB NO 011A01 BY SalEwAac TYSE L
<br /> N O. MODEL NUMBER SC-11111002 INSTALL DESCV IRIPTION�OfF or t OPERATIOaust Fan, N: Fe.,Fxea.t as 1a Fw Lgnre aat a Fx..
<br /> 1 - Grease Box 4039261
<br /> U tea,
<br /> JOB NAME Ruby Bakery&Cafe- Lodi, CA DATIE
<br /> 10/29/2019 o ECP 1-1co
<br /> HINGE KIT DETAIL0� �' � m
<br /> 1 - Fan Base Ceramic Seal - Installed At Plant - For Grease Ducts W
<br /> 1 KEF-1 I U:) o �, Q
<br /> 1 - ECM Wiring Package - Manual Or 0-10VDC Reference Speed Control (TELCO Motor), 2 BREAKER PANEL TO PRIMARY CONTROL PANEL CONTROL PANEL TO ACCESSORY ITEMS I C z V Il
<br /> N
<br /> CCW Rotation (1)Responsibility. Electrician Responsibility. Electrician I O
<br /> 3 BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED I ' +- 0 U
<br /> FAN CONTROL PANEL COMPONENT
<br /> FAN ACCESSORIES BREAKER PANEL PRIMARY CONTROL PANEL 03 OU
<br /> 4 MICROSWITCH 1 '
<br /> F11,,K11 iPH - - H.1 H1 CONTROL PANEL 94:NOW
<br /> 0 a ..... 01 ......._ } i i O�C� ,
<br /> EXHAUST SUPPLY s 5 A coNTROL PowER Do NOT WIRE FRI, bWITCH nR1 - Nc... I
<br /> WIRE C, T°COMMON 1
<br /> FAN TO GFCI OR SHUNT TRIP BREAKER. WIRE ARI TO S NORMALLY H CLOSED 2 STAMP:
<br /> • UNIT TAG POWER.SWITCH#, -C q Np'AP Q-
<br /> 6 1ST HOOD LIGHT BREAKER SHARED W/CONTROL IF MORE THAN ON1E CONTINUITY WHEN`DARMED.
<br /> -AVE M+�� OFF I I I I V
<br /> N0. GREASE GRAVITY WALL SIDE GRAVITY MOTORIZED WALL WIREM�.N III
<br /> ' D DETAIL 6 ��- ��- c-una -� FIRE SYSTEM AR1 - _ ----- ---a,
<br /> „A„ CUP DAMPER MOUNT DISCHARGE DAMPER DAMPER MOUNT M�^A;79^" KEF 1 - FNl N SERIES A5 SHOWN G "� OQ ONY q
<br /> -- �pFE IONq
<br /> 1 KEF-1 YES MGGP: ,5 A
<br /> L
<br /> Hot CONTROLPANEL ALL SWITCHES FACTORY WIRED
<br /> 9 I I
<br /> CURB ASSEMBLIES BREAKER 1PH N tO . TO J4 CAT-5 CONNECTION
<br /> 115 V -- -- �--_nd --�� SWITCHES M 39333
<br /> V
<br /> - Lu
<br /> ' ON 10 MOCP: 15 A HOOD LIGHTS, O
<br /> NO. TAG WEIGHT ITEM SIZE 1 CONTROLPANEL
<br /> BLACK --
<br /> s O
<br /> FAN Wj - -- --- MMITE - ---
<br /> HOOD LIGHTS WIRE To J-BOX ON TOP OF HOOD J I Ln
<br /> n » fz 1400 W MAX
<br /> 1 # 1 KEF-1 31 LBS Curb 19.500"W x 19.5001 x 20.000"H Vented Hinged 12 CONTROL PANEL TO FANS N s�-9 CHANXG
<br /> Responsibility. Electrician THE FOLLOWNG CONNECTIONS _
<br /> MAY OR MAY NOT BE
<br /> 19 1/2" PRIMARY PANEL FANS REQUIRED BASED ON JOBSITE rn FOFCAUF��
<br /> 13 SPECIFICATIONS r
<br /> / n Load Wiring T1 LEc-i_[-or ---- FAN-01- ---KEF 1 iLA:6.J HOT TO SHUNT COIL SHUN COIL
<br /> 19 1/2" CONTROL PANEL ST
<br /> 14 r£ 2/N„E_, ,,,_,,,_ _,,,,,,_, HP:0.500
<br /> C-1 T2 voLT:ns v SIGNAL FOR ------NEUTRAL FROM-SHUNT COIL - X
<br /> WIRE DIRECT GN ..-..............._capu0p......................................................................................{p EXTERNAL ST TERMINAL IS ENERGIZED IQ Q
<br /> TO STARTER WIRE TO SHUNT TRIP IN FIRE CONDITION /+ LL
<br /> 15 DISCONNECT U 0
<br /> FAN #1 DU50HFA — EXHAUST FAN (KEF-1) FAN: 02 CONTROL PANEL
<br /> CURB VENTED C2 --------------------coMMEN
<br /> SUP-2 FLA: NORMALLY OPEN i N
<br /> 16 Load Wirin LEc tJ_Hor 13— o SPARE FIRE AR -- --- '
<br /> FEATURES: - -
<br /> CURB 9 T1 HP:0.333
<br /> G.-2 LEc z1N€uTa L ____ write SPARE CONTACTS WILL MAKE C2 TO
<br /> VOLT:115 v SYSTEM DRY AR2 WHEN SYSTEM IS ARMED.THEY �
<br /> GN -cgou o aaeeN ° CONTACT ARE USED TO DISABLE EQUIPMENT
<br /> DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS) 17 WIRE DIRECT WIRE TO FACTORY OR PROVIDE SIGNALS (NOT FOR
<br /> 28 7 $ BUILDING FIRE ALARM THE MUST , cc
<br /> / — ROOF MOUNTED FANS 20" ^ TO STARTER PROVIDED CONDUIT DROP BE WIRED DIRECTLY IT THE LANSULOCATED w'
<br /> RESTAURANT MODEL eLY(Y///J[ ALARM L AUTOc SWITCH LocATED Y/
<br /> GREASE BOX 18 N ANSUL AUTOMAN) U - ■ —
<br /> (OPTIONAL) � BMs SWITCH �
<br /> GREASE PIPE — UL705 AND UL762 AND ULC—S645 CONTROL PANEL H1 - .........
<br /> — VARIABLE SPEED CONTROL 20 GAUGE 1s TO 01 - I LJJ
<br /> SIGNAL SWITCH THROUGH BMS
<br /> WILL ACTIVATE ZONEi FANS AND O
<br /> CONSTRUCTION SWITCH LIGHTS
<br /> OPTIONAL STEEL EXTERNAL
<br /> — INTERNAL WIRING
<br /> A FAN IN CLOSED POSITION — WEATHERPROOF DISCONNECT ( 2a
<br /> — THERMAL OVERLOAD PROTECTION SINGLE PHASE) 21 p
<br /> — HIGH HEAT OPERATION 300•F (149•C)
<br /> CD
<br /> GREASE CLASSIFICATION TESTING ` ` 3" FLANGE 22
<br /> p p
<br /> 27 1/4 NORMAL TEMPERATURE TEST ;'� Q
<br /> EXHAUST FAN MUST OPERATE CONTINUOUSLY za U 0
<br /> 21 1/2cc
<br /> WHILE EXHAUSTING AIR AT 300•F (149•C) 19 ROOF OPENING z4 aj � Q)
<br /> UNTIL ALL FAN PARTS HAVE REACHED DIMENSIONS
<br /> THERMAL EQUILIBRIUM, AND WITHOUT ANY 19 m
<br /> cL0
<br /> • DETERIORATING EFFECTS TO THE FAN WHICH
<br /> GREASE DRAIN WOULD CAUSE UNSAFE OPERATION. A B C D E F G H I DO
<br /> UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. FACTORY WIRING L
<br /> ABNORMAL FLARE—UP TEST PITCHED CURBS ARE AVAILABLE 0" MOTOR POWER CIRCUIT SCHEMATIC
<br /> '�l z 0 CIRCUIT BOARDS =3 06 CD
<br /> • 2 ; ( EXHAUST FAN MUST OPERATE CONTINUOUSLY FOR PITCHED ROOFS. 1 J9 120V DCV Rev. 2.11.00 U U
<br /> • WHILE EXHAUSTING BURNING GREASE VAPORS 0° 1 BK Uj
<br /> • / AT 600-F 316°C FOR A PERIOD OF CONTROL INPUT m m 24V 8 9 11 3 1SPA HMI Rev. 2.11.00
<br /> 1 1 3 1 4 i WH r 14 AWG C-1 MTR:KEF-1 C
<br /> 12" T1 CO
<br /> ( ) SPECIFY PITCH: AR1 BK 12ov H1-LINE, „s v �� FLA:6.3 RA_ RD-
<br /> 15 MINUTES WITHOUT THE FAN BECOMING 3 BK N1-NEUTRAL, ����� 3 REL Y z4 VDG
<br /> EXAMPLE: 7/12 PITCH = 30° SLOPE RELAY RELAY
<br /> ' DAMAGED TO ANY EXTENT THAT COULD CAUSE / ® Do NOT CONNECT 3 J1 2 3 4 5 6 BK a No 4 3 No 4 3 00 O
<br /> J6 NC 2 1 NC
<br /> 2 1
<br /> F--------------------------------i AN UNSAFE CONDITION. KS BK TO SHUNT TRIP + 2av a0
<br /> BREAKER. SEE PS-01 DC 4 A 2-2 MTR:SUP-2 call 8 7 colt 8 7 ,
<br /> ����0
<br /> FAN BASE H1 ---- SCHEMATIC FOR N L AC m ;SPA z CONA:60�-K09D10 COM 6 5 COM 6 5 J
<br /> 2 BK /y�
<br /> I I INSTALLATION 115 V HP:0.333 W
<br /> i 19 I BK + A 13 COMPONENT LIST en
<br /> OPTIONS ADDITIONAL REQ. v o
<br /> I I o LABEL DESCRIPTION
<br /> 5T-x 51a°ee -smog
<br /> GREASE BOX.
<br /> PANEL UD�III G �---------- �zx U) w
<br /> oL-x "ed°Qa
<br /> 21, FAN BASE CERAMIC SEAL — INSTALLED AT
<br /> PLANT — FOR GREASE DUCTS. 3 C-x C."t 5°r �/�� U
<br /> ` ' ECM WIRING PACKAGE — MANUAL OR PS-' P°we,18-S,p 24VA-IC L0
<br /> i►
<br /> � M°P
<br /> V
<br /> ' ✓ 0-10VDC REFERENCE SPEED CONTROL
<br /> (TELCO MOTOR), CCW ROTATION. RA- ov Rel°y oPOT r -0
<br /> DUCTWORK BETWEEN 3411001840.
<br /> RDx 4vDc180 Y J D
<br /> � EXHAUST RISER ON HOOD ""°$1880e0 M
<br /> AND FAN (BY OTHERS) 4 W
<br /> J7 120V J
<br /> X01 1 BK BK 1 W R ��H1
<br /> 08
<br /> 21 B < � C6
<br /> K �_
<br /> 5 BK -HGOOOGHTS'=�R--JUMPER"N1
<br /> SF1 q)- BK C-2 U (�
<br /> O
<br /> r U
<br /> ATTENTION: INSTALLER SHOULD SUPPLY PHOENIX / FRIGIKING - DOWN DISCHARGE FEATURES N1
<br /> ENOUGH ELECTRICAL CORD TO LET FAN MAKE 6 BL PR N' 0
<br /> COMPLETE SWING. E c Dc+�CRo-17 Rol o
<br /> FAN IN OPEN POSITION CABINET.ALL DED, HOT DIPPED GALVANIZED STEEL AR, K 7RA-
<br /> B1aN, D
<br /> —FIELD 1MPoNG
<br /> cuR6 F MULTILAYER BOTTOM PAN FINISH 7 BL-BLDEFAGTGy-(RE NG
<br /> BK-BLACK YW-YELLOW
<br /> GREASE 0 0 0 0 M_W-0TE GR-GREEN
<br /> BR-BROVFI PR-PURPLE
<br /> RD-RED
<br /> DRY CONTACTS (SHOWN DE-ENERGIZED) ORAL-ORAL STRIPE (�
<br /> BOX ,4 AWG RA-1-1 BL
<br /> COVER o 0 0 o PEBLAR XT ARCHITECTURAL FINISH DN/OFF /RD-RD/GN STRIP
<br /> 0 0 0 MAKE UP AIR INTERLOCK. WITH FIRE RD/GN-RD/GN STRIPE L� ^
<br /> JUMPER 4L�� AH/8L 1M-I/BL STRIPE
<br /> D C A � HEAVY DUTY MOTOR AND PUMP 8 G YW JOB NAME
<br /> c
<br /> Rubv Bakery&Ca...
<br /> DRAWING
<br /> V 1 0
<br /> �
<br /> NOTES DES RIPTION OF OPERATION n`
<br /> ECPM03 VJ
<br /> Jt Izov t Ph OF
<br /> PERAT
<br /> 1f.2 1 Edtauet Fm,1 Supply
<br /> 0 0 Fan,E A..t m in Fire,
<br /> Dght.out lnFire
<br /> RP RESIDENTIAL UNITS ARE 1 PHASE ONLY 9 _ O
<br /> U L(IF 11, REVISIONS
<br /> MOTORS ARE SHIPPED LOOSE � 0
<br /> B
<br /> DA 11/21/19 AA PC Comments
<br /> COOLER CAN BE AS A SEPARATOR DOWN DISCHARGEORED ORE0 END DISCHARGE 0 = Q Q
<br /> JOB NO DRAWN BY
<br /> GREASE BOX WE DA ( 1
<br /> SUPPLY AIR UNIT DIMENSIONAL DATA 14 x 16 x 6 Box DW0 No EDP 1-2 M �J �J
<br /> - - - 0
<br /> MODEL CABINET DIMENSIONS APPROX WT. � '' _^ 0
<br /> ATTACH GREASE BOX COVER TO THE CURB 3" BELOW U)
<br /> TOP EDGE OF CURB. A B C D E F G H J K P R OPER SHIP - - -
<br /> USING (3) LONG (3/4" LG.) SCREWS AS SHOWN. FRIGIKING O Q
<br /> INSTALL GREASE PIPE AS SHOWN. 350FD � �
<br /> 32 28 28 16 16 3.25 6 14 4.25 — — — 175 108
<br /> - - - Cn
<br /> DATE: 10/29/2019 j
<br /> GREASE PIPE DEMONSTRATIONS ARE AVAILABLE AT THE
<br /> FAN INFORMATION CALIFORNIA BAY AREA DISPLAY CENTER DWG.#:
<br /> • FAN EXHAUST FAN SUPPLY FAN FOR PRICES AND QUESTIONS, CALL 4039261
<br /> UNIT FAN UNIT MODEL # MODEL TAG CFM S.P. RPM H.P. VOLT FLA BLOWER HOUSING TAG CFM S.P. RPM H.P. 0 VOLT FLA THOMAS THAI - - - E
<br /> N0.
<br /> PHOENIX / FRIGIKING REFERENCE JOB# 4039261 DRAWN
<br /> 2 350FD DOWN DISC . 810 .5 690 .33 1 115 7.2 REG91@CAPTIVEAIRE.00M BY. T.Thai N0. Date Drn Remarks z
<br /> MUA-1 PHONE: (415) 956-2200 FAX: (919) 227-5940 DRAWN: A. Amadio a�
<br /> SCALE: —
<br /> GREASE BOX INSTALLATION 3/4'° = 1 '-0" CHECKED: HT Lj__
<br /> 1. A PRE-WIRED ELECTRICAL CONTROL PACKAGE SHALL BE MASTER DRAWING
<br /> DATE: 11/25/2019
<br /> PROVIDED TO OPERATE THE HOOD LIGHTS AND FANS.
<br /> 2 PACKAGE TCH PANEL WITH LIGHT
<br /> SWTHCH(ES)AAND REDLL ISLIGHT DT OF WIFAN SWTCH(ES), STARTER/ SCALE: AS NOTED �
<br /> OVERLOAD ASSEMBLY FOR EACH FAN(OPTIONAL), NUMBERED
<br /> INPUT/OUTPUT TERMINAL STRIPS, AND A TERMINAL FOR
<br /> DOUBLE-DUAL FIRE SYSTEM MICROSWITCH CONNECTION. JOB NO: 22471
<br /> 3, ONE RELAY IS WIRED TO MICROSWITCH (IN FIRE SYSTEM)
<br /> FOR SUPPLY FAN SHUTDOWN AND OTHER RELAY FOR SHEET TITLE
<br /> ADDITIONAL FIRE SYSTEM ACTIVATED DRY CONTACTS.
<br /> 4. ELECTRICAL CONDUIT DROPS FROM THE FAN(S) SHALL BE
<br /> CONNECTED TO THE NUMBERED TERMINAL STRIP. CONDUIT
<br /> BETWEEN THE PRE-WIRE PACKAGE AND FANS) SHALL BE
<br /> SUPPLIED BY THE ELECTRICAL CONTRACTOR. SHEET N O■ CD
<br /> KITCHEN HOOD
<br /> 2 \
<br /> ELECTRICAL PACKAGE NOTES DETAILS & DATA
<br /> 2 of 4
<br /> SHEET n
<br /> If a Builder and/or Subcontractor deviates in anyway
<br /> from any design produced by California Living & Energy
<br /> without the expressed written consent of California Living \
<br /> & Energy then all warranties become null and void. For Q)
<br /> further clarification refer to clauses & warranties section
<br /> of our bid proposal & contract section VI. 0
<br /> ALL PROJECT DRAWINGS, SPECIFICATIONS AND OTHER WORK PRODUCT PREPARED BY CALIFORNIA LIVING & ENERGY ARE INSTRUMENTS OF SERVICE FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY OF CLE WHETHER THE PROJECT IS COMPLETED OR NOT. ANY REVISIONS, CHANGES, ADAPTATIONS
<br /> ETC. TO CL&E's INSTRUMENTS OF SERVICE, ALSO KNOWN AS BUT NOT LIMITED TO DESIGN MUST BE APPROVED IN WRITING BY CLE. REUSE BY CLIENT OF ANY OF CL&E's INSTRUMENTS OF SERVICE FOR ANY PROJECT OTHER THAN THE PROJECT THAT IS THE SUBJECT OF THIS AGREEMENT IS UNAUTHORIZED.
<br />
|