AIR DISTRIBUTION DEVICE, SEESCHEDULE. LAY-IN SHOWN-SURFACE MOUNT SIMILARSUPPLY DUCT SIZE ASSHOWN ON PLANSDUCT SEALER AT SPINCOLLAR CONNECTIONTO MAINMAX. 4' PER FOOTROUND SPIN-IN COLLAR MOUNTIN SIDE OF DUCT UNLESSSPECIFICALLY SHOWN OTHERWISEUPPER ATTACHMENT PER SMACNASPIRAL SHEET METAL DUCTNECK SIZE TO MATCHFLEX DUCT SIZE INDICATEDSHUTTER DAMPERINSULATE TOP PANELOF LAY-IN DIFFUSERCEILING (T-BAR SHOWN)GYPSUM BOARD SIMILARR6 DUCT INSULATIONWHEN IN UNCONDITIONEDLOCATIONS40"MIN.1/2"x10" HOT DIPPEDGALV.LAG BOLTS- 3 @ EA, SIDES4x CURB(E) ROOF(N) 4x10 WD. BM.(N) 20d NAIL, NAILEDTO RAFTER BELOW(E) PARAPET WALLMET. CHANNELW/ WASHER& LOCKNUT4x6 D.F. SUB JOIST ONBOTH SIDES W/ U HANGERCEILING GYP.BD.HOOD EXHAUST DUCT:DOUBLE-WALL GREASE DUCTSEE M0.4 & M0.5 SHEETSFOR MORE DETAILS4 - 1/2" DIA. HOODSUPPORTED RODSSEE A-4 FOR DETAILS2 ROWS 1/4" SCREWS@ EA. STUDNOTE:CLEARANCE "X"LESS THAN 12"REQUIRES CEILINGENCLOSURE PANNEL(E)5/8" TYPE "X"GYP. BOARD20 GAUGE METAL STRAPw/3/8" DIA. SUPPORT RODX 7"MIN.REFER TO SHEET M0.2 FORADDITIONAL HOOD DETAILSA11/21/19AAPC Comments--------------------------------A. AmadioHT11/25/2019AS NOTED22471REVISIONSNo.RemarksDRAWN:CHECKED:DATE:SCALE:JOB NO:DateSTAMP:SHEET TITLEToll Free: 800-498-4110
<br />Ceres, CA 209-538-2879
<br />LIVING & ENERGY
<br />CALIFORNIA
<br />A Division of William Lilly & Associates, Inc.
<br />Title 24 Compliance - Residential/Non Residential
<br />CONSERVATION FOR THE CALIFORNIA LIFESTYLE
<br />Fax: 209-538-2885
<br />www.califliving.comDrnSHEETREVISIONSNo.RemarksDRAWN:CHECKED:DATE:SCALE:JOB NO:DateSTAMP:SHEET TITLEToll Free: 800-498-4110
<br />Ceres, CA 209-538-2879
<br />LIVING & ENERGY
<br />CALIFORNIA
<br />A Division of William Lilly & Associates, Inc.
<br />Title 24 Compliance - Residential/Non Residential
<br />CONSERVATION FOR THE CALIFORNIA LIFESTYLE
<br />Fax: 209-538-2885
<br />www.califliving.comDrnSHEETFausto & Lynn Echeverria
<br />(415) 404-5194
<br />Ruby Bakery & Cafe
<br />11 S. Church St, Lodi CA 95240 MECHANICAL GENERAL NOTESABBREVIATIONSABBR.DISCRIPTIONØ, DIA.DIAMETER#POUND/NUMBER&AND@AT%PERCENTΔPPRESSUREDIFFERENTIALΔTTEMPERATUREDIFFERENTIAL°FDEGREE OFFAHRENHEITɸ/PHPHASE (ELECTRICAL)±PLUS OR MINUSA.P.ACCESS PANELABVABOVEADAUTOMATIC DAMPERADJADJUSTABLEAFFABOVE FINISH FLOORAFGABOVE FINISH GRADEAFUEANNUAL FUELUTILIZATIONEFFICIENCYAHUAIR HANDLING UNITALTALTERNATEBDBAROMETRICDAMPERBDDBACKDRAFT DAMPERBELBELOWBLK'GBLOCKINGBOTBOTTOMBTUHBRITISH THERMALUNITSCCCOOLING COILCDCONDENSING DRAINCEFCEILING EXHAUSTFANCSFCEILING SUPPLY FANCFMCUBIC FEET PERMINUTECHK VLVCHECK VALVECLGCEILINGCONCCONCRETECONTCONTINUOUSCOPCOEFFICIENT OFPERFORMANCECTGCEILING TRANSFERGRILLECUCONDENSING UNITDPENNY NAILDBLDOUBLEDEGDEGREESDETDETAILABBR.DISCRIPTION(E)EXISTINGEAEACHEDBENTERING DRY BULBEERENERGY EFFICIENCYRATIOEFEXHAUST FANELECELECTRICEQEQUALEWBENTERING WET BULBEXHEXHAUSTEXH AEXHAUST AIREXH DCTEXHAUST AIR DUCTFFURNACEFAUFORCED AIR UNITF/CCFURNACE & COILFLX DCTFLEX DUCTFJFLOOR JOISTFLRFLOORFOWFACE OF WALLFPMFEET PER MINUTEFTFOOTFT'GFOOTINGGAGAUGEGALVGALVANIZEDGPMGALLON PER MINUTEHORHORIZONTALHPHORSE POWERHSPFHEATING SEASONALPERFORMANCEFACTORHTGHEATINGIAEWBINDOOR AIRENTERING WET BULDIN.INCH∠ANGLE, STEELLBSPOUNDSMSDMULTI-SHUTTERDAMPERMAXMAXIMUMMBHBTUH/1,000MCAMINIMUM CIRCUITAMPACITYMDMANUAL DAMPERMINMINIMUMMOCPMAXIMUM OVERCURRENTPROTECTION(N)NEWN/ANOT APPLICABLEN.C.NORMALLY CLOSEDN.I.M.CNOT IN MECHANICALCONTRACTN.O.NORMALLY OPENABBR.DISCRIPTIONOADBOUTSIDE AIR DRYBULBOBDOPPOSED BLADEDAMPEROCON CENTEROHOVERHEADOPOPERATINGOSAOUTSIDE (FRESH) AIRP.O.C.POINT OFCONNECTIONPBDPARALLEL BLADEDAMPERPHPHASEPSFPOUNDS per Sq. Ft.PSIPOUNDS per Sq. In.REQ'DREQUIREDRLREFRIGERANT LIQUIDRPMREVOLUTIONS PERMINUTERSREFRIGERANTSUCTIONRETRETURN'RARETURN AIRRADRETURN AIR DUCTRGD DCTRIGID DUCTS.M.SHEET METALSDSMOKE DETECTORSEERSEASONAL ENERGYEFFICIENCY RATIOSENSSENSIBLESQSQUARESTDSTANDARDSq InSQUARE INCHSPLYSUPPLYSASUPPLY AIRSADSUPPLY AIR DUCTT,T-STATTHERMOSTATTCPTEMPERATURECONTROL PANELTDRTIME DELAY RELAYTHKTHICKTYPTYPICALUNOUNLESS OTHERWISENOTEDVERTVERTICALVTRVENT TO ROOFVTWVENT TO WALLW/WITHW/OWITHOUTWHWATER HEATERWTWEIGHTWTGWALL TRANSFERGRILLEXFMRTRANSFORMERMECHANICAL LEGENDDESCRIPTIONSYMBOLTSUPPLY AIR DUCTRETURN AIR DUCTEXHAUST DUCTMAKE-UP AIR/OUTSIDE AIR (OA)PRIMARY CONDENSATE DRAINSECONDARY CONDENSATE DRAINTHERMOSTAT (T1 = ZONE 1)CEILING EXHAUST FAN (CEF)WHOLE HOUSE VENTILATION CEILING EXHAUST FAN (CEF):·WHOLE HOUSE VENTILATION FAN SHALL BE PER ASHRAE STD.62.2-2013.WHOLE HOUSE EXHAUST FANEXHAUST DUCT - VENT TO ROOF (VTR)EXHAUST DUCT - VENT TO WALL (VTW)CEILING SUPPLY FAN (CSF)SUPPLY AIR DIFFUSER 4-WAY (CS-4)SUPPLY AIR DIFFUSER 3-WAY: CEILING (CS-3), FLOOR (FS-3)SUPPLY AIR DIFFUSER 2-WAY: CEILING (CS-2), FLOOR (FS-2)SUPPLY AIR DIFFUSER 1-WAY: CEILING (CS-1), FLOOR (FS-1), WALL (WS-1)SUPPLY AIR WALL DIFFUSER 3-WAY (WS-3)RETURN AIR GRILLE (CR-1)JUMP DUCT W/ CEILING TRANSFER GRILLES (CTG)WALL TRANSFER GRILL (WTG)LAUNDRY MAKE UP AIR TRANSFER GRILLEMANUAL VOLUME DAMPERMOTORIZED VOLUME DAMPER45° TEE / 90° TEE / 45° CROSS / 90° CROSS45° WYE / DUCT DROP / DUCT RISER / DUCT CAPCTGCTGT1WTG26 GAUGE FLEXIBLE DUCT MAY BE USED AND INSTALLED PER CMC APPENDIX A PART B.DUCTS TO BE ROUTED & SIZED AS SHOWN ON THE VENTILATION PLAN.PROVIDE APPROPRIATE SCREENED TERMINATION CAP, BACKDRAFT DAMPER AND SWITCHING (PER UTILITY PLAN).FANS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AS DEFINED IN THE MANUFACTURER'S PRODUCT INSTALLATIONDOCUMENTATION.SEE INDIVIDUAL MECHANICAL PLANS FOR EXHAUST FAN DUCT SIZES.BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING PER 2013 CGBC SECTION 4.506.UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, BATHROOM EXHAUST FANS MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BEREADILY ACCESSIBLE. HUMIDISTAT CONTROLS SHALL BE CAPABLE OF ADJUSMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 80 PERCENT PER 2016 CGBC SECTION4.506.THE ABOVE FANS HAVE BEEN SPECIFIED TO MEET THE MINIMUM REQUIREMENTS. AN ALTERNATE FAN THAT MEETS OR EXCEEDS THE ABOVE SPECIFICATIONS MAY BEINSTALLED & VERIFIED WITH A CF-6R FORM.AIR DISTRIBUTION DEVICE SCHEDULESURFACE-MOUNT, ROUND NECK, RADIAL SHUTTER DAMPER12" x 12" CEILING DIFFUSERCD-3MK. NO.METALAIRE 5700YES4-WAYNOTES:SEE PLANS1.THE THROW PATTERN SHALL MATCH THE PLANS. ALTERNATE SIZES OR MANUFACTURERS MAY BE UTILIZED. THE CONTRACTOR SHALL BASE THEALTERNATE SELECTIONS UPON A MAXIMUM PRESSURE DROP OF 0.04 @ DEVICE & A MAXIMUM FACE VELOCITY FOR SUPPLY GRILLES OF 700 FEETPER MINUTE. THE INSTALLING CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF THE SUBSTITUTED DEVICES MANUFACTURER'SCRITERIA.2.ACCEPTABLE ALTERNATE MANUFACTURERS SHALL BE J&J, AIRMATE, HART & COOLEY, LIMA, TRU-AIR.3.TG-1 SHALL BE MINIMUM 1 SIZE LARGER THAN JUMP DUCT SIZE ( I.E. JUMP DUCT = 8"Ø, TG-1 SHALL BE 10"x10"). JUMP DUCT SIZE SHALL BE MINIMUM 1SIZE LARGER THAN SUPPLY DUCT SIZE ( I.E. SUPPLY DUCT = 7"Ø, JUMP DUCT SHALL BE 8"Ø).MANUFATURER &MODEL NO.APPLICATION &TYPEBLOWPATTERNMSD/PBDNECKSIZEREMARKS1.SCOPE: FURNISH AND INSTALL COMPLETE AND OPERATING HVAC SYSTEMS. INCLUDING, BUTNOT LIMITED TO, AIR CONDITIONING UNITS, FORCED AIR UNITS, AIR HANDLERS, HEAT PUMPS,DX COILS, DUCTS, DAMPERS, GRILLES, CONTROLS AND REFRIGERANT LINES ETC., ASGENERALLY DELINEATED ON THE MECHANICAL DRAWINGS.2.CODES: ALL WORK, MATERIAL AND EQUIPMENT SHALL BE FURNISHED AND INSTALLED INCOMPLIANCE WITH THE FOLLOWING CODES AS ADOPTED AND AMENDED BY THE INSPECTINGAUTHORITY HAVING JURISDICTION. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMITTHE INSTALLATION OF WORK, MATERIAL OR EQUIPMENT NOT CONFORMING TO THESE OR OTHERCODES APPLICABLE TO THE PROJECT:A.2016 CALIFORNIA BUILDING CODE - TITLE 24 PART 2, CCRB.2016 CALIFORNIA ELECTRICAL CODE - TITLE 24 PART 3, CCRC.2016 CALIFORNIA MECHANICAL CODE - TITLE 24 PART 4, CCRD.2016 CALIFORNIA PLUMBING CODE - TITLE 24 PART 5, CCRE.2016 CALIFORNIA FIRE CODE - TITLE 24 PART 9, CCRF.2016 CALIFORNIA GREEN BUILDING STANDARDS CODE - TITLE 24 PART 11, CCRG.2016 EDITION OF TITLE 24, TITLE 24 CALIFORNIA CODE OF REGULATIONSH.2016 CALIFORNIA ENERGY CODEI.VENTILATION REQUIREMENT PER ASHRAE STD. 62.1-20163.WORKMANSHIP: ALL WORKMANSHIP SHALL BE DONE IN A NEAT WORKMANLIKE MANNERACCORDING TO THE BEST TRADE PRACTICES BY THOSE SKILLED IN THAT PARTICULAR TRADE.EQUIPMENT, DUCTS, GRILLES ETC., SHALL BE PLUMB, LEVEL, SQUARE OR CENTERED ETC., TOPROVIDE A NEAT AND PLEASING APPEARANCE. ALL EQUIPMENT SHALL BE INSTALLED IN STRICTCOMPLIANCE WITH THE PARTICULAR MANUFACTURER'S RECOMMENDATIONS. AND CONFORMWITH ACCA/ANSI STANDARD 5 QI SPECIFICATION4.AVAILABLE POWER: THE HVAC CONTRACTOR SHALL CONFIRM ALL SYSTEM VOLTAGES BEFOREBIDDING OR ORDERING EQUIPMENT AND ALLOW FOR BUCK & BOOST TRANSFORMERS IFREQUIRED.5.DUCT SIZING & AIR BALANCE: THE AIR DISTRIBUTION SYSTEM (DUCTWORK & DEVICES) HASBEEN SIZED & BALANCED TO DELIVER THE SPECIFIED AIR QUANTITIES AS NOTED ON THEPLANS, FOLLOWING THE PROCEDURES & REQUIREMENTS OF THE LATEST EDITION OF THE ACCAMANUAL "J" & MANUAL "D". BALANCING SHALL BE PER PROCEDURAL STANDARDS FOR TESTING,BALANCING & ADJUSTING ENVIRONMENTAL AIR SYSTEMS. THE CONTRACTOR SHALL PROVIDEACCESSIBLE & ADJUSTABLE VOLUME DAMPERS (SHOWN OR NOT) AS REQUIRED TO BALANCETHE SYSTEMS AND MAINTAIN A NOISE CRITERIA LEVEL NOT TO EXCEED 25-30. CONTRACTOR TOENSURE SYSTEM IS BALANCED.6.EXISTING INFORMATION: LOCATION, SIZE, MATERIAL ETC., OF EXISTING SYSTEMS,STRUCTURES, COMPONENTS, PIPING, ETC., IS DEEMED TO BE RELIABLE BUT IS NOTGUARANTEED. THE CONTRACTOR SHALL FIELD VERIFY ALL DATA BEFORE PROCEEDING WITHANY WORK. NO EXTRA COST SHALL BE ALLOWED FOR CONDITIONS NOT AS SHOWN.7.ACCURACY: PLANS ARE DIAGRAMMATIC. THE POSITION/LOCATION OF EQUIPMENT, REGISTERS,GRILLES, DUCTS ETC., SHOWN ON PLANS ARE APPROXIMATE AND MAY BE SHOWN AS IS FORCLARITY PURPOSES. ACTUAL LOCATIONS FOR EQUIPMENT SHALL TAKE INTO CONSIDERATIONACCESSIBILITY, SERVICE REQUIREMENTS, LOCATION OF TRUSSES AND JOISTS, ETC. THECONTRACTOR SHALL CONFIRM ALL DIMENSIONS, LOCATIONS & CLEARANCES OF AC UNITS,FURNACES, AIR HANDLERS, EQUIPMENT, FANS, WALLS, PARTITIONS, BEAMS, TRUSSES ETC.,AGAINST ARCHITECTURAL & STRUCTURAL DESIGN PLANS FOR LOCATION, CONSISTENCY &ACCURACY PRIOR TO COMMENCING ANY WORK. IF ACTUAL DUCT FIELD LOCATIONS VARY TOSIGNIFICANTLY AFFECT FINAL AIR FLOW, IT IS THE RESPONSIBILITY OF THE MECHANICALCONTRACTOR TO CONTACT THE MECHANICAL ENGINEER PRIOR TO INSTALLATION.8.COORDINATION WITH OTHER TRADES: THESE PLANS WERE CLOSELY COORDINATED WITHAVAILABLE STRUCTURAL & ARCHITECTURAL PLANS PROVIDED TO CALIFORNIA LIVING ANDENERGY AT THE TIME THE DESIGN WAS PERFORMED. SUBSEQUENT CHANGES TO THEPROVIDED SPECIFICATIONS OR DRAWINGS MAY ADVERSELY AFFECT THE FEATURES OF THEMECHANICAL DESIGN. EVERY REASONABLE ATTEMPT HAS BEEN MADE TO BE CONSISTENT WITHTHE BUILDING STRUCTURAL DESIGNS AND PLANS AND TO FOREWARN THE BUILDER/OWNER OFPOTENTIAL STRUCTURAL CONFLICTS OR CONSTRAINTS OR MODIFICATIONS REQUIRED. IT IS THEOWNER/BUILDER'S RESPONSIBILITY TO PROVIDE FIELD COORDINATION OF THESE PLANS WITHFRAMING, WALLS, ROOFS, ETC., AND OTHER TRADES PRIOR TO CONSTRUCTION. CONTACT THEARCHITECT AND/OR THE MECHANICAL ENGINEER IF CONFLICTS ARISE MAKING MODIFICATIONNECESSARY. SPECIAL CARE MUST BE TAKEN WHEN LAYING OUT FLOOR JOISTS/TRUSSES ORROOF JOISTS/TRUSSES AS NOT TO IMPEDE THE UPPER OR LOWER OPENING OF ANY VERTICALDUCT CHASE.9.ENERGY FEATURES: ALL CALCULATIONS AND SPECIFIED EQUIPMENT OR DEVICES ARECONSISTENT WITH THE ENERGY CRITERIA & FEATURES PROVIDED TO CALIFORNIA LIVING ANDENERGY AT THE TIME OF DESIGN. ANY SUBSEQUENT CHANGES TO THE SUPPLIED CRITERIAMAY AFFECT FEATURES OF THE DESIGN INCLUDING BUT NOT LIMITED TO EQUIPMENT SIZES,DUCT SIZES & LOCATIONS, OUTLET/INLET DEVICE SIZES & LOCATIONS ETC.10.EQUIPMENT SIZING AND AIR DISTRIBUTION: THE EQUIPMENT, DUCT SIZING, AND ROOM-TO-ROOMCFM REFLECTED ON DRAWINGS HAS BEEN SIZED BY ACCA APPROVED MANUAL S, D, AND J. ANYCHANGE IN SIZING FOR EQUIPMENT, DUCTING, DUCT RUN LENGTHS OR INSTALL DEVEIATIONSWILL NOT BE WARRANTED UNDER CURRENT DESIGN UNLESS APPROVED IN WRITING BY CLEPRIOR TO INSTALLATION.11.EQUIPMENT SUBSTITUTIONS: EQUIPMENT SUBSTITUTION MUST BE APPROVED BY CLE PRIOR TOINSTALLATION AND MUST ACCURATELY DEMONSTRATE EQUIVALENCE OF UNIT CAPACITIES,AIRFLOW PERFORMANCE BASED UPON DETAILED DESIGN CONDITIONS, INCLUDING BUT NOTLIMITED TO: SEER'S, EER'S, HSPF'S, COP'S, AFUE'S, SENSIBLE CAPACITIES @ DESIGNCONDITIONS, AIRFLOWS AT DESIGN STATIC PRESSURES, HEATING OUTPUT CAPACITIES, COILSTATIC PRESSURE DROPS, EQUIVALENT LENGTH OF FITTINGS ETC . ALL EQUIPMENT SHALL BEINSTALLED IN STRICT COMPLIANCE WITH MANUFACTURER'S PRINTED INSTALLATIONINSTRUCTIONS.12.UNDUCTED PLENUMS - PROHIBITED: ALL CAVITIES/SPACES INTENDED TO CONVEY SUPPLY,RETURN OR EXHAUST AIR SHALL BE PROVIDED WITH APPROVED TYPE DUCT BOARD, SHEETMETAL DUCT, FLEXIBLE DUCT OR OTHER APPROVED MATERIAL FOR THAT SPECIFIC PURPOSE.PLYWOOD, GYPSUM BOARD, OSB, WOOD/METAL STUDS, ETC. ARE APPROVED MATERIALS.BOXED-IN FRAMING MEMBERS, "PLATFORM RETURNS", PANNED JOISTS AND STUD BAYS ANDOTHER NON-DUCTED BUILDING CAVITIES ARE PROHIBITED.13.DUCT CHASES, SOFFITS & DROPPED CEILINGS: SOME CHASES, SOFFITS OR DROPPED CEILINGSTHAT APPEAR ON THE MECHANICAL PLANS MAY NOT APPEAR ON THE ARCHITECTURAL ORSTRUCTURAL PLANS. CHASES, SOFFITS, AND DROPPED CEILINGS SHALL BE CONSTRUCTED SOAS NOT TO PINCH, CRIMP, CRUSH OR OTHERWISE OBSTRUCT THE DUCTWORK. A GENERAL RULEOF THUMB IS TO HAVE AN INSIDE CLEAR CHASE DIMENSION EQUAL TO THAT OF THE DUCTDIAMETER PLUS 2 INCHES (INCLUDING INSULATION THICKNESS IN CALCULATION). ENSURE THATFLEXIBLE DUCTS TO MAINTAIN A MINIMUM RADIUS OF TURN OR PROVIDE SHEET METAL ELBOWSAS REQUIRED.14.ENVIRONMENTAL AIR DUCTS: ALL ENVIRONMENTAL AIR DUCTS (CLOTHES DRYER MOISTUREEXHAUST DUCTS, DOMESTIC KITCHEN RANGE HOOD DUCTS) SHALL BE CONSTRUCTED OFGALVANIZED STEEL SHEET METAL DUCT WITH SMOOTH INTERIOR SURFACES. ALL DUCTSSHALL BE CONSTRUCTED PER CMC CHAPTER 6.15.PIPE INSULATION: THE SUCTION REFRIGERANT LINE FROM THE INDOOR COIL TO THE OUTDOORUNIT (AC OR HEAT PUMP) SHALL BE INSULATED WITH A MINIMUM R-3 INSULATION. INSULATIONUSED FOR REFRIGERANT SUCTION LINES SHALL BE WATER RETARDENT AND PROTECTED FROMPHYSICAL DAMGE AND UV DETERIORATION PER 2016 CALIFORNIA ENERGY CODE SECTION150(J)2B.16.DRYER VENTS: 2016 CMC 504.3 ALL INSTALLED DRYER VENTS SHALL MEET (MAX 14', (2) 90°ELBOWS W/ 4"Ø DUCT).17.REFRIGERANT PORT PROTECTION: AIR CONDITIONING REFRIGERANT CIRCUIT ACCESS PORTSLOCATED OUTDOORS SHALL BE PROTECTED FROM UNAUTHORIZED ACCESS WITH LOCKING TYPETAMPER-RESISTANT CAPS OR IN A MANNER APPROVED BY THE AUTHORITY HAVINGJURISDICTION PER 2016 CMC 1106.1418.ALL DUCT OPENINGS AND OTHER RELATED DISTRIBUTION COMPONENT OPENINGS SHALL BECOVERED DURING CONSTRUCTION PER CALGREEN CODE 4.504.1.19.ENVIRONMENTAL AIR EXHAUST DUCTS SHALL TERMINATE A MINIMUM OF 3'-0' AWAY FROMOPENINGS INTO THE BUILDING, PER C.M.C. 504.5.20.PROVIE MINIMUN 10'-0" LENGTH OF DUCT AT JUMP DUCTS.MATERIAL SPECIFICATIONS1.ALL MATERIALS SHALL HAVE A MINIMUM PERFORMANCE TEMPERATURERATING PER UL-181 (DUCTS), UL-181 (CLOSURE SYSTEMS FOR RIGIDFIBERGLASS DUCTS) UL-181B-FX (CLOSURE SYSTEMS FOR FLEXIBLE DUCTS)AND/OR UL-181BM (MASTIC); BUTYL BACKED TAPE MAY ALSO BE USED TOSEAL DUCT, DUCTBOARD AND METAL DUCTS.2.CLOTH BACKED, RUBBER ADHESIVE TAPES (TYPICAL DUCT TAPE) SHALL NOTBE USED EVEN IF UL-181 RATED.3.ALL MATERIALS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF NOMORE THAN 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF 50.4.ALL FACTORY FABRICATED DUCT SYSTEMS SHALL INCLUDE UL-181 LISTEDDUCTS WITH APPROVED CLOSURE SYSTEMS INCLUDING BUT NOT LIMITED TOCOLLARS, CONNECTIONS, & SPLICES.5.ALL PRESSURE SENSITIVE & HEAT ACTIVATED TAPES USED IN THEMANUFACTURE OF RIGID FIBERGLASS DUCTS SHALL BE UL-181A LISTED.6.ALL PRESSURE SENSITIVE TAPES AND MASTICS USED IN THE MANUFACTUREOF FLEXIBLE DUCTS SHALL BE UL-181B-FX (TAPE) OR UL-181BM (MASTIC)LISTED.7.FACTORY MADE DUCT FOR FIELD-FABRICATED DUCT SYSTEMS SHALL BEUL-181 LISTED.8.SEALANTS SHALL BE UL-181BM LISTED, NON-TOXIC AND WATER RESISTANT.9.SEALANTS FOR INTERIOR APPLICATIONS SHALL PASS THE ASTM TESTS C-731(EXTRUDABILITY AFTER AGING) & D-2202 (SLUMP TEST ON VERTICALSURFACES).10.SEALANTS AND MESHES SHALL BE RATED FOR EXTERIOR USE.11.SEALANTS FOR EXTERIOR APPLICATIONS SHALL PASS ASTM TESTS C-731,C-732 (ARTIFICIAL WEATHER TESTING), AND D-202.12.ALL TAPE USED FOR FLEXIBLE DUCT CONNECTIONS SHALL BE UL-181B-FXLISTED OR BE ALUMINUM-BACKED BUTYL ADHESIVE TAPE (15 MIL MINIMUMTHICKNESS).13.TAPE USED FOR DUCTBOARD SHALL BE UL-181A LISTED AND SO INDICATEDWITH A UL-181A MARKING OR BE ALUMINUM BACKED BUTYL ADHESIVE TAPE(15 MIL MIN. THICK).14.DRAWBANDS SHALL BE EITHER STAINLESS STEEL WORM DRIVE HOSE CLAMPSOR UV RESISTANT NYLON DUCT TIES. ALL DRAWBANDS SHALL HAVE AMINIMUM TENSILE STRENGTH RATING OF 150 LBS & A MINIMUM PERFORMANCETEMPERATURE RATING OF 165 DEGREES FAHRENHEIT (CONTINUOUS PERUL-181A TYPE TEST). ALL DRAWBANDS SHALL BE TIGHTENED ASRECOMMENDED BY THE MANUFACTURER WITH AN ADJUSTABLE TENSIONINGTOOL.DESIGN/INSTALLATION NOTES1.PER CEC-400-2012-004-CMF-REV2 SECTION 150.0(H) 1.A.B.C. BUILDING HEATING,COOLING LOADS AND DUCT DESIGN ARE DETERMINED USING A METHODBASED ON THE FOLLOW: THE ACCA MANUAL J, D, AND S.2.THE DUCTWORK HAS BEEN SIZED FOR SPECIFIC CARDINAL ORIENTATION.THEREFORE, THE MANUAL VOLUME DAMPERS AT THE SUPPLY PLENUMCOLLARS ARE REQUIRED FOR COMFORT BALANCING BASED UPONORIENTATION.3.THE SEER, EER AND AFUE RATINGS FOR THE MECHANICAL EQUIPMENT AREBASED UPON BEST KNOWLEDGE AVAILABLE FROM THE MANUFACTURER.THEY RESERVE THE RIGHT TO UPDATE, REVISE OR DELETE EQUIPMENT ORTHE PRINTED EFFICIENCY RATINGS. THE CONTRACTOR SHALL VERIFY ANYSUBSTITUTION OF COILS OR CONDENSERS SHALL MEET THE MATCHEDRATINGS AS PROVIDED BY THAT MANUFACTURER.4.FINAL DUCT AND SUPPLY REGISTER LOCATION MAY BE ADJUSTED BYMECHANICAL CONTRACTOR WITH APPROVAL OF CLE IN ORDER TO MAINTAINSTRUCTURAL INTEGRITY.5.CL&E IS NOT RESPONSIBLE FOR PROPER SYSTEM PERFORMANCE IF THEINSTALLATION DOES NOT CONFORM TO OOUR DESIGN, AND MATCH ALL SIZEDCOMPONENTS.6.CONTRACTOR MUST CONTACT CL&E WITHIN 24HRS OF ANY FIELD ISSUESTHAT PREVENT A QUALITY INSTALLATION. CL&E WILL NOT BE RESPONSIBLEFOR FIELD ISSUE NOT REPORTED WITHIN THIS TIMELINEEXHAUST FAN AND MAKE-UP AIR FAN SCHEDULETYPEMARKMANUFACTURER/ELEC. MOTOR REQT'SVOLTWATTSPHOP. WT.LBS.NO.CFMS.P.AMPSEF-1SONESMODEL NUMBERDESCRIPTIONS1829001.0"---------------0.5 HPEF-2CEILING MOUNTED120112.5DIRECT DRIVE800.10"0.3BACKDRAFT DAMPER, CEILING GRILLE, 4" DUCT SIZE,OCCUPANCY SENSOR0.3800.25"------7.6BROAN XB80ALUMINUM ROUND DIFFUSER, ROUND NECK, D-3 DAMPERCD-1METALAIRE 3000ROUND CEILING DIFFUSERRADIALYESSEE PLANSSURFACE-MOUNT, ROUND NECK, RADIAL SHUTTER DAMPERCD-2METALAIRE 570024" x 24" CEILING DIFFUSER4-WAYYESSEE PLANS12 X 12 DOOR GRILLEDG-1METALAIRE DGDFNO------STEEL RESTROOM DOOR GRILLE, 150 CFM EXHAUST FANSCEILING RETURN GRILLECR-1METALAIRE CC5-6NOSEE PLANSLAY-IN, CUBE CORE, PROVIDE BOOT FOR ROUND DUCT CONNECTIONINCLUDE ROOF CURB, DUCT TRANSITION PIECESKITCHEN HOOD EXHAUST FANCAPTIVE-AIREDU50HFA1156.3 FLAM-0.1MECHANICALNOTES &DETAILSMAU-11175---------------0.33 HPINCLUDE ROOF CURB, DUCT TRANSITION PIECESFRIGIKING EVAP. COOLER350FD1157.2 FLAKITCHEN HOOD MAKE-UP FAN8100.5"---SIDE-WALL RETURN GRILLECR-2METALAIRE CC5-1NOSEE PLANSSURFACE-MOUNT, CUBE CORE, PROVIDE BOOT FOR ROUND DUCT---SCALE:2_ROUND DUCT SUPPORTIN ATTICNONESCALE:3_SPIRAL DUCT CONNECTION DETAILTO SUPPLY BOOTSNONESCALE:4_HOOD INSTALLATIONDETAILSNONESCALE:1_EXHAUST FAN WALLPENETRATIONNONESTAINLESS STEELSTRAP14"ALUMINUM, MFR. BYBROAN MODEL 642SEE PLANS FOR DUCT SIZEOPEN/CLOSE FLAPPERAS BACKDRAFT DAMPERWATER TIGHT CAULKINGALL AROUND6"MIN.KEYED NOTES1.3" WIDE ELASTOMETRIC FLASHINGSTRIP.2.GSM PENETRATION FLASHING SETIN PREHEATED SURFACE.3.PROVIDE APP MODIFIED BITUMENSTRIP WITH ALUMINUM COATED.4.12" CLEAR.5.3" STAGGERED NAILING.6.PIPE7.PROVIDE FIRE STOPPING MATERIALSIMILAR TO U.L. FC 1002REQUIREMENTS. FILL VOID MIN. 14"HIGH x 38" WIDE BEAD OF CAULK8.PLYWOOD9.ROOF CAP10.2 HR. FIRE DAMPER @ RATED CLGAPPLICATIONS @ STAIRWAYS.SCALE:5_EXHAUST FANROOF PENETRATIONNONE47610827531AA
|