Laserfiche WebLink
N ' ^ <br /> . U <br /> w <br /> N U <br /> 8'25 3 1 iii ° o RED INC, ARGHITEGTS <br /> d�sa�stixaa�sL�a 1 I II I II 121?J STREET,MODESTO,GA 95354 <br /> 209.522.8900 <br /> � � I III I II II <br /> I II <br /> o ' 3.04 4 Install quick coupler 0 I III , „ SEAL: <br /> I ; adjacent to trash enclosure IRRIGATION SCHEDULE <br /> < /4" I III I II I i �' 1 3 Ex. Retail I II i I II P{•1DSCAPk- <br /> v ^ ^ 3/4 V i iu 1 SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI GPM DETAIL �p e Horned cgiP� <br /> II II <br /> / <br /> ^ ^ CID <br /> Oo (7 <br /> I <br /> Hunter RZWS-18-CV 30 0.25 K L5.1 v <br /> 18" long RZWS with installed .25g pm bubbler, Check Valve, 1/2" � r <br /> Y " <br /> I <br /> z <br /> o r-- -- --- ------ ----- - B�---- o HO <br /> °O0 swing <br /> joint pipe <br /> n,4/2N0 <br /> rtnl DA°°op0000poJ <br /> 1 + + + + - O 4, n D + + O + I II 02.2-1.1c{ <br /> NN <br /> I 1I + + + F O °� o • �O p + C + +I + + <br /> + + + 'v + + + + + + <br /> + + + + + + o+ + + + + <br /> SYMBOL MANUFACTURER/MODELDESCRIPT <br /> ION <br /> sT°lOF CAI <br /> 4- <br /> NAL <br /> + + 100 0000 °o o0O0° + o + <br /> Q + 00 00000 0000 + + + + + + + + + Hunter ICZ-101-25 E L5.1 <br /> Drip Control Zone Kit. 1" ICV Globe Valve with 1HY100 filter <br /> + system. Pressure Regulation: 25psi. Flow Range: 2 GPM to 20+ + <br /> Controller and Weather Sensor + + T II GPM. 150 mesh stainless steel screen. <br /> Y " CONSULTANT: <br /> • Locate controller on wall of the electrical + + + 1%4" Toro T-FCH-H-FIPT M L5.1/4 <br /> room. Extend adequate electrical supply 2 5.48 \F <br /> P <br /> ; Flush Valve, plumbed to flush manifold at low point. Install in 6" <br /> to controller. location + + + ® I II <br /> round plastic box.Mainline determined in field. Locate weather <br /> I I I I + <br /> Shown schematically. Install sensor in a nearby location with + q <br /> Lu I I along back or walk or curb as unimpeded rainfall and sunlight and + +� + ^ Area to Receive Drip Emitters G,H, M / L5.1 <br /> feasible. Grou valves in I Hunter HE-B <br /> r APO <br /> = I I p connect to controller. + , <br /> shrub areas. + + I , 1 4'82 _____J Point Source Drip Emitter with Self Piercing Barb with diffuser <br /> 0 i + by MILTON _ + I 1" cap. Install on 1/2" or 5/8" polyehtylene supply tubing to each <br /> I s + - „ plant. Install emitters equally around the plant at the rates <br /> /4n + - - - - - - 1CVdW0 13VdIN00 13VdIN00 i3VdIN00 10tl 00 1 dW00I ^ " provided below. Install supply tubing min. 3" below grade with <br /> I - - -- - - I C + + P lint 0 Conne tion #1 staples 5 oc max. S a rn H a r n e d <br /> + + - - -- - - o + Provide flush valve in 6" round plastic box at the end of each L a n d S C a e <br /> I I + + I; I Actual Illocation, meter and <br /> 1 1 I I ba kfl 1 preve ter, refer to Civil assembly. p <br /> 14 1 +0 - Er� ine;w p plan Emitter Notes: Arch I t e C t U re <br /> I 4" 4" - - - I 20HE-B emitters (1 assigned to each 1 gal. plant) P o B o x 2 2 7 5 <br /> / \ \ P0nto Conne ion #1 Oakdale, CA 95361 <br /> $-�� 20HE-B emitters (4 assigned to each 15 gal. plant) <br /> Did ra6pmatic I cation, meter z o 9 3 s o - 7 3 7 6 <br /> ° I g 20HE-B emitters (6 assigned to each 24 plant) w w w . h a r n e d I a . c o m <br /> o and backflow pr venter per Civil <br /> + OC # I I 20HE-B emitters (2 assigned to each 5 gal. plant) <br /> c? Engineer's plans. <br /> 7.59 5 ^� <br /> + + • �4" ! u <br /> 1„ 1" + MV M terllvalve an flow se sor, <br /> I CO A COMPACT ON CLEANAIRI CLEANAIRI CLEANAIRI CLEANAIRI + + + SYMBOL MANUFACTURER/MODEL/DESCRIPTION <br /> I COMPACT COMPACT PARKING NO PARKING VANPOOLIEV VANPOOLIEV VANPOOLIEV VANPOOLIEV FS I IOC to cownstre m of bac flow <br /> pr vener. Hunter ICV-G F/L5.1 <br /> 1Y4" j4" 1�a" %4 4YZ4 ;i Plastic Electric Remote Control Valves, Globe Configuration, <br /> s 3 3 dJ ; a with NPT Threaded Inlet/Outlet, size per plan <br /> /4" /4" ��� II II <br /> MON. o i 0 Hunter HQ-44LRC C/ L5.1 <br /> 12.5 9 D 4D D 74„ I '� Quick coupler valve, yellow rubber locking cover, red brass and <br /> 3 �� <br /> 1Y2„ /4 s LTi " stainless steel, with 1" NPT inlet, 2-piece body. <br /> Z31100dNtlA A31100dNtlA A31100 tlA A31100dNtlA lOVdW00 II <br /> �4" /4 �4n I MV NV310 I'dIV NV310 I MV Ntl I iy4Mtl31O + I Y <br /> + + MV Hunter ICV-G 1-1/2" D/ L5.1 <br /> I II <br /> 4" + + Master Valve, 1-1/2" Plastic Electric Valve, Globe Configuration, b HILTON~ <br /> with NPT Threaded Inlet/Outlet y <br /> + + <br /> +11+ + + + + ++ + + I © Hunter IC-1200-PL A/ L5.1 <br /> T T T T T T + + + + 1 1 r + + r <br /> F + + 1 + + + 0+ �+ + + + a p + + ;4" S T + + + �� + + + + Y� " Modular Controller, 12 stations, Plastic Cabinet. Provide <br /> + + + + + + + + + + + + + + + + + + ►�J ICM-600 modules as needed. <br /> l <br /> I I 0 Q Z <br /> I i i <br /> Hunter WSS B L5.1 O <br /> - ---------- --- -------- - - �► ~ Y Y / <br /> _ - <br /> - ____ --___ I „ Wireless Solar, connect to controller, install per manufacturer's <br /> it 117 <br /> l____f___ \i \ i - <br /> / I recommendations. <br /> 1 ` ` <br /> 7.95 6 II ,;' II II 11CC�� I p <br /> � LiFS Hunter HFS-150 D/ L5.1 v <br /> 1; 8 9.67 7 9.04 ;; l O �� " <br /> Flow Sensor, 1-1/2„ Schedule 40 Sensor Body, 24 VAC, 2 amp. <br /> .. II II <br /> POC�#1 Point of Connection 1-1/2" <br /> I I I 'I II Verify pressure prior to installation. <br /> II r--------------------� I III II II <br /> I II I II <br /> Irrigation Lateral Line: PVC Schedule 40 <br /> I I i i iii o " <br /> I 11 II II <br /> Irrigation Mainline: PVC Schedule 40 ° <br /> I I I II I YI " O n n n <br /> l ; ii i I II = _ _ _ _ _ _ = Pipe Sleeve: PVC Class 200 SDR 21 L/ L5.1 �� <br /> Place (2) 3" PVC sleeves at each location. <br /> I I <br /> Valve Callout n <br /> Valve Number nn n <br /> II II `� I 1 II I II II <br /> I II II I II II II II II II 0 <br /> V I I ( II II <br /> # # Valve <br /> ==-I � (?ll <br /> � I II II II II <br /> I I II II I I II <br /> I I II II II Y � <br /> ---- - - - - - ----X---------- <br /> I ------------I 11--- - --- ---- --- ---- --- ----�--� II IAI II i # Valve Size <br /> nW// I I r--------- I------- <br /> r------------------------------------------------------------ vLeaO�l�y1 .-ivtrivz - l II III I YI „ • <br /> --------------------------------------- " r-------- <br /> I II I II I <br /> F} �ZOL�O � " II I °nnI <br /> ��y�yy�y����ryyLr 1 I I II I I I 1 II p <br /> � I I II I I '711 I I II I II II N <br /> � 1 ^ i i �^r�YYzrityzeatr>re��zriau� " I I I 1 <br /> I <br /> Ex. Hotel <br /> N <br /> 1 II 1 a u nl 1 a <br /> O <br /> 3 IRRIGATION NOTES z <br /> 0 1. Contractor shall become familiar with the drawings, specifications, and site conditions prior to beginning work. Should conflicting information be found in these Q <br /> documents or between these documents and site conditions, notify the Landscape Architect before proceeding with the work in question. <br /> 0 2. All existing utilities, water lines, and fire hydrants shall remain connected and in full continuous operation unless specifically directed otherwise. Z <br /> 6 3. Irrigation design is based on a minimum 40 psi and maximum 80 psi static water pressure at the point of connection after the water meter. Verify prior to ordering <br /> materials or starting work. Notify the Landscape Architect if water pressure differs from pressure on which the design is based. Variation from design pressure <br /> 6 may require changes and additions to the equipment specifications. (Y C) <br /> ° 3.1. Booster Pump: If verified static pressure is less than minimum required design pressure, provide a booster pump as appropriate to yield the required <br /> minimum pressure based on anticipated maximum and minimum flows required for system to operate within water window requirements. <br /> ( 3.2. Pressure Regulator: If verified static pressure is more than maximum, design pressure, provide a pressure regulator as appropriate to yield the required <br /> pressure based on anticipated maximum and minimum flows required for system to operate within water window requirements. <br /> 4. Irrigation plan is diagrammatic. Actual routing of pipe and location of equipment shall be determined based on field conditions and as directed by the Landscape <br /> Architect. Install pipe and equipment in landscape areas wherever possible unless specifically noted otherwise. Stake layout of mainline and primary laterals for REVISIONS: <br /> o field review and approval prior to trenching. Field adjust existing irrigation system as necessary. <br /> 5. Pipe Sizing: PLANNING 10/05/2018 <br /> E 5.1. Minimum pipe size shall be 3/4". <br /> 0 HILTON 10/18/2018 <br /> 5.2. Unlabeled pipe segments shall be equal to the size of the segment immediately upstream. <br /> 3 5.3. In making adjustments to irrigation zone layouts Contractor shall be responsible to determine pipe sizes as required to deliver water pressure required for <br /> 6 <br /> 6 each outlet device considering flow rate, elevation changes, length of run, and other factors affecting pressure loss. Maximum flows in various pipe <br /> sizes shall not exceed the following guidelines. Flows may may need to be significantly less than the maximums stated below to off-set other factors <br /> affecting pressure loss: <br /> 5.3.1. 3/4": up to 6 gpm. <br /> 5.3.2. 1": 6to8gpm. <br /> 5.3.3. 1-1/4": 8 to 16 gpm. <br /> s <br /> 5.3.4. 1-1/2": 16 to 23 gpm. <br /> d <br /> 5.3.5. 2": 23 to 38 gpm. <br /> ° 5.4. Mainline pipe sizes shall not be changed without written approval of the Landscape Architect. RED PROJECT # 18050 <br /> Q 5.5. Lateral line pipe runs of lengths greater than the typical distance between outlet devices shall not be made without written approval of the Landscape HILTON # 18-428NO <br /> w <br /> CY Architect. PLANNING # SPR-18-102 <br /> 0 6. Do not install the irrigation system as shown on the drawings when it is obvious in the field that obstructions, grade differences or differences in the area <br /> y dimensions exist that might not have been considered in the engineering. Notify the Landscape Architect of all such conditions immediately upon discovery. In PERMIT # - <br /> the event this notification is not provided, the Contractor shall assume full responsibility for all revisions necessary in response to field conditions with no APN # Ia6-2-70-23 <br /> o additional compensation. <br /> cl <br /> 7. Controller(s): DATE: 02.2 . <br /> 7.1. Locate as directed. Extend electrical service to controllers and dedicate one breaker of proper size for each controller. Provide one additional duplex outlet DRAWN: RSH <br /> at each controller location. GHEGKED: RSH <br /> 7.2. Electrical service to controllers shall be completed by a licensed electrical contractor in accordance with all applicable codes. <br /> 0 8. Sleeves: SHLA Job#18-005 <br /> 8.1. All pipe under existing and proposed paving shall be installed in sleeves. SHEET TITLE: <br /> 8.2. Sleeves are shown for contractor's convenience. Contractor shall be responsible to coordinate irrigation sleeve locations and installation with other trades. <br /> 8.3. Extend all sleeves 18 inches beyond paving, cap and clearly mark by approved means to facilitate recovery. <br /> °n 8.4. Install sleeves to accommodate future paving where indicated or as may be needed. <br /> 9. Spray Heads and Rotors: <br /> s 9.1. Install perpendicular to grade unless otherwise noted in plans. Irrigation PIACI <br /> 0 <br /> 10.Drip Emitters: <br /> ° 10.1. Install drip supply lines minimum 3" below grade. <br /> 10.2. Located emitters 3"-6" from main trunk or stem. <br /> 10.3. Include bug-guard and galvanized stake(s) for each emitter.. <br /> NORTH <br /> NOteS: ua2m <br /> 11. Contractor to flush entire system and adjust all delivery devices and assemblies for complete coverage and reduced over-spray, prior to project completion. 0' ' ' 40' <br /> 12.An irrigation audit shall be completed by a Certified Landscape Irrigation Auditor in conformance with the jurisdictional Water Efficient Landscape Ordinance SHEET NO.: <br /> 6 (WELD or MWELO. The audit shall be provided to the jurisdictional agency for review and approval. See details on Sheet L5.1 . <br /> Scale: 11"=20'-10" <br /> � Iunow,l,►nars below. <br /> L3. 1 <br /> 811 before you dig. <br />