V/ <br /> PLUMB/NG NO TES: <br /> PLUMBING FIXTURE SCHEDULE PLUG AT FINISH GRADE <br /> PLUMBING LEGEND 2# LEAD CAP OVER ROOF SAFE ROOF SAFE PER ROOF MANUFACTUIRER'S OR FLUSH w/ FLOOR <br /> 1) ALL FIXTURES, MATERIALS AND WORKMANSHIP SHALL BE IN STRICT ACCORDANCE AND TUCKED A MINIMUM ❑F 2" WARRANTY DETAILS - SEE ARCH DWGS . U <br /> MARK MAKE/MODEL TRIM ACCESSORIES SYMBOL DESCRIPTION SYMBOL DESCRIPTION WITH THE LATEST EDITION OF THE UNIFORM BUILDING CODE AND STATE OF AND <br /> VENT PIPE AND 6" OVER PULL SM COLLAR OVER ROOF SAFE AND CRETE BOX LABELED SEWER , w <br /> -CW COLD WATER LINE VALVE CALIFORNIA TITLE 24 HANDICAP REQUIREMENTS & LOCAL ORDINANCES, OUTSIDE OF PIPE, PIPE SHALL SEAL WITH SILICON WATER TIGHT 'OR' <br /> WC-1 KOHLER 1.28 GPF 17" ADA TANK TYPE ELONGATED WATER CLOSET,POLISHED KOHLER K-4650 ELONGATED HOT WATER LINE �o� EXTEND A MINIMUM OF 10" AFR. FINISHED ROOF - SEE ARCH II ��INI HEDCLEANOUT <br /> OOOROX <br /> ELLISTON CHROME HANDLE, BRASSCRAFT KTSR17FC STOP, B1-12DLF HOSE, WAX SEAT, NON LOCKING COVER, BALANCING VALVE 2) OWNER WILL PAY FOR ALL APPLICABLE PERMITS AND INSPECTION FEES AS <br /> ' TD TRENCH DRAIN GAS COCK REQUIRED BY LOCAL CODES, DWGS - FLASHING INSTALLATI❑N SHALL <br /> K-12767 RING, RIGHT HAND 12 RI, LOOSE KEY. COLOR BY ARCHITECT. RI PER ADA REQT S ��� <br /> MATCH ROOFING MANUFACTURERS U <br /> `�' �w WASTE LINE AC ABOVE CEILING DRAW BAND DETAILS T❑ MAINTAIN WARRANTY <br /> WC-2 NORTH POINT 1.28 GPF 17" ADA ELONGATED WATER CLOSET SLOAN 3780018 FV SEAT RIM HEIGHT AT 17" 3) OWNER SHALL PAY FOR ALL SEWER CONNECTION CHARGES WATER METER AND TAP <br /> ' GW GREASY WASTE LINE BG BELOW GRADE � <br /> 25-733-0 BEMIS 1055 000 SEAT, PREMIER 191200 WAX RING WITH SLEEVE, 10"RI, INSTALL FLUSH VALVE TO FEES, MAJOR FACILITIES CHARGES AS MAY BE REQUIRED BY LOCAL GOVERNING ATTACH SUPPORT TO BLOCKING Q <br /> HV HORIZONTAL VENT MV MIXING VALVE LONG SWEEP 'L' <br /> C) AUTHORITIES, W/1-j"0x2" LAG FOR WOOD, <br /> 90 DEGREE <br /> CLOSET. --SD— ST M DRAIN LINE WC WATER CLOSET RED INC ARCHITECTS <br /> R L-1 STERLING UNDER COUNTER SELF RIMMING LAVATORY, DELTA 630TP320 0.5 GPM WF RI PER ADA REQUIREMENTS —C— CON NSATE DRAIN UR URINAL 4) ROUGH-IN AND CONNECT TO ALL FIXTURES AND EQUIPMENT REQUIRING GAS, WATER 2-#8x1- "SM SCREWS FOR STEEL <br /> 1/4"-1/2" OVERLAP INVERT - SEE PLAN 1217 J STREET, MODESTO, CA 95354 <br /> STINSON FAUCET, ZURN ZW1017 MIXING VALVE, DEARBORN 760W-1 GRID DRAIN & V, VR, VTR VE , VENT RISER, VENT THRU ROOF L LAVATORY OR WASTE LINES AS INDICATED ON PLANS, FOR SIZES 209.522.8900 <br /> z 442007-U-0 PVC P-TRAP BRASSCRAFT KTSR17FC STOPS & B-16A SUPPLY HOSES -SS, SSD- WAS E, WATER DROP S SINK BLOCKING AS SEE PLUMBING FLOOR <br /> 0 2002 P-TRAP & ANGLE STOP INSULATION. COLOR BY ARCHITECT. 5) INSULATE HOT WATER LINES AND DRAIN LINES UNDER LAWS WITH INSULATION WREFER <br /> � REQUIRED PLAN FOR SIZE <br /> RW R WATER LEADER SS, MS SERVICE SINK, MDP SINK PER TITLE 24 REQUIREMENTS. SEE TABLE ON DRAWINGS. SEAL: <br /> a L-2 STERLING UNDER COUNTER SELF RIMMING LAVATORY, KOHLER K-7515-CP 0.5 GPM RI PER ADA REQUIREMENTS RD ROOF DRAIN DF DRINKING FOUNTAIN 18 GA PIPE BRACET OPENING IN ROOF MINIMUM 1/8", 2 - WAY CLEANOUT <br /> STINSON WF FAUCET W/INTEGRAL MIXING VALVE, DEARBORN 760W-1 GRID DRAIN AD AREA DRAIN FHS FIRE HOSE STANDPIPE 6) PROVIDE CLEANOUT ON ALL WASTE LINES AT UPPER TERMINAL OF EACH RUN OF WITHIN 24" ❑F ROOFXIMUM 1/2" LARGER THAN PIPE DETAIL S\ONAL F <br /> 442007-U-0 & PVC P-TRAP BRASSCRAFT KTSR17FC STOPS & B-16A SUPPLY HOSES CB, DI CATCH BASIN (DROP INLET) INV INVERT ELEVATION PIPING, LINE TERMINATIONS, CHANGES IN DIRECTION AND AT 100 FT, INTERVALS PQ 5 N <br /> a DECK 2 REQUIRED T❑ STRUCTURAL/ARCG DWGS �, G G. D G1- <br /> 0 2002 P-TRAP & ANGLE STOP INSULATION. COLOR BY ARCHITECT. (PER U,P,C.) q <br /> (n 4__CO CLEAN OUT FIN, GD. FINISH GRADE PIPE CLAMP BOLTED T❑ OPENING IS LARGER THAN 8"0 <br /> 3CS-1 ADVANCE TABCO 3 COMPARTMENT POT SINK COMPLETE WITH ADVANCE TABCO 15" SWING REFER TO KITCHEN PIPE UP THROUGH <br /> SPOUT 18x18 SINK BASINS, I�WCD WALL CLEAN OUT POINT OF CONNECTION " " <br /> 2-24 DRAIN BOARDS. DRAWINGS FOR EXACT SIZE 7) WATER CLOSETS SHALL BE 1,28 GPF WATER CLOSETS, URINALS SHALL BE 0,5 GPF, SUPPORT STRAPS W/ 8x1 MBS a � � <br /> ROOF PLUG AT FINISH GRADE �? <br /> z FCO FLOOR CLEAN OUT AD ACCESS DDDR PROVIDE AUTO FLUSH CONTROLS ON ADA DESIGNATED WATER CLOSETS AND AT ALL OR FLUSH W/ FLOOR * - M29759 =_ <br /> CL BT-1 STERLING KOHLER K-99898-CP PRESSURE BALANCING COMBINATION TUB/SHOWER ORDER LEFT/RIGHT OUTLET YCO YARD CLEAN OUT CI CAST IRON URINALS. AUTOFLUSH UNITS SHALL BE 24VAC POWERED. COORDINATE WITHREN. 6-30-20 Q <br /> PERFORMA ASSEMBLY WITH KOHLER K-72418-H-CP SHOWERHEAD SINGLE LEVER AS NEEDED RI PER ADA S S VENT THRU R ❑ ❑ E 5 <br /> P <br /> w �FD FLOOR DRAIN � ELECTRICIAN <br /> CENTER LINE , <br /> 71041110 FAUCET INTEGRAL STOPS Z-8773 DRAIN ASSEMBLY. COLOR BY REQUIREMENTS, KOHLER �cHAN��' O� <br /> � ' ' �FS FLOOR SINK HDR HEADER DETAIL F F <br /> o ARCHITECT. K-T99762-2, KOHLER 8) LAVATORY AND SINK FAUCETS SHALL BE CERTIFIED BY THE MANUFACTURER WITH PO NCR Box LABELED SEWER of C <br /> K-11748-KS, KOHLER <br /> TP TRAP PRIMER DwN DOWN THE CALIFORNIA ENERGY COMMISSION/ COMPLY WITH TITLE 24 REQUIREMENTS FOR o <br /> a K-98351-CP, KOHLER CW, D, R COLD WATER (DROP) (RISER) MBH THOUSANDS OF BTU PER HOUR, IMBH = 1CFH BRASS CLEANOUT BOX <br /> MAXIMUM ALLOWABLE FLOW RATES, (0,5 G.P.M. MAX,), PROVID PUSHBUTTON OR IN FINISHED FLOOR <br /> D K-15135-CP HW,D,R,RT HW SUPPLY (DROP) (RISER) (RETURN) NIPC NOT IN PLUMBING CONTRACT ELECTRONIC EYE IN ASSEMBLY OCCUPANCIES AND IN DINING PUBLIC RESTROOMS, <br /> SH-1 SHOWER PAN ACRYLIC MOLDED ADA COMPLIANT SHOWER PAN WITH KOHLER RI PER ADA REQUIREMENTS, THW T TEMPERED HOT WATER (115° F) HW HAND WASH STATION <br /> N W/DELTA K-TS99761-4-CP PRESSURE BALANCING SHOWER VALVE W/KOHLER KOHLER K-304-KS, KOHLER G, PG NATURAL GAS LOW PRESSURE (PROPANE) Hs HOSE STATION 9) PLUMBING CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES, (IE: <br /> X SHOWERHEAD K-72418-H-CP 1.5 GPM HEAD, SINGLE LEVER FAUCET, INTEGRAL STOPS, K-7395-CP STRUCTURAL, MECHANICAL, AND ELECTRICAL). " " O CONSULTANT: <br /> HPG HIGH PRESSURE GAS WH WATER HEATER 1/2 x3 LAG BOLT <br /> o ZURN ZN-415 STYPE B STRAINER FLOOR DRAIN. COLOR BY ARCHITECT. TO BLOCKING IN WALL ❑ <br /> M CA COMPRESSED AIR STOP - SEE FIX CONNECTION SCHEDULE 10) PLUMBING CONTRACTOR SHALL FURNISH ALL EQUIPMENT MATERIAL LABOR ETC, <br /> MS-1 FOOD SERVICE SEE FOOD SERVICE DRAWINGS ITEM 33 EMBED 2" <br /> DRAWINGS ITEM HB HOSE BIBB xxxxxx DEMOLITION, TBR WHETHER SHOWN ON THESE PLANS OR NOT, NECESSARY TO PROVIDE A COMPLETE, <br /> Z © UNDER PLUMBING CONTRACT FSP FIRE SPRINKLER WORKABLE, AND CODE-APPROVED PLUMBING SYSTEM, SEE PLUMBING FLOOR E e <br /> ° PLAN FOR SIZE Z ❑ <br /> El <br /> ul 33 18 GAx2" WIDE STRAP 3 - WAY CLEAN ❑ UT 2 <br /> w LS-1 GRAINGER FIBERGLASS LAUNDRY SINK W/INTEGRAL STRAINER AND DRAIN, CHICAGO sov sHur OFF VALVE COP CUT OFF POINT 11) GAS MAIN AND METER TO BE BY UTILITY COMPANY (VERIFY LOCATION). PROVIDE LOCATE 12" FR❑M ❑rn o ❑ <br /> = FL7TG100 891-ABCP FAUCET. COLOR BY ARCHITECT. � WE <br /> GAS SHUT-OFF VALVE CONSPICUOUSLY MARKED. TOP ❑F TANK DETAILP O Z ao 8 <br /> EEWSH-1 FOOD SERVICE SEE FOOD SERVICE DRAWINGS ITEM 16 RUN 1" H&CW TO UNIT E N <br /> = DRAWINGS ITEM 12) PROVIDE WATER HEATER WITH PRESSURE, TEMP., RELIEF VALVE AND 314' DRAIN 7 W � U) ? 8 <br /> ~ 16 LINE TO THE EXTERIOR OF THE BUILDING WITH THE END OF THE PIPE NOT MORE00 W <br /> HWS-1 FOOD SERVICE SEE FOOD SERVICE DRAWINGS ITEM 17 <br /> FIXTURE CONNECTION SCHEDULE THAN TWO (2) FEET NOR LESS THAN SIX (6) INCHES ABOVE THE GROUND AND 48" o — � U ❑ E:DRAWINGS ITEM <br /> PLUMBING SANITARY WATER POINTING DOWNWARD, <br /> m (D 0- foo ❑ <br /> 17 FIXTURE SEWER VENT COLD HOT TYPICAL FLOOR SINK w -9N � -o <br /> WATER CLOSET FV -1' 2" 1" I I 13) VERIFY ALL EXISTING CONDITIONS (ON-SITE) AND UTILITY CONDITIONS (OFF-SITE) w/D❑ME STRAINER N J El El ❑ <br /> HWS-2 FOOD SERVICE SEE FOOD SERVICE DRAWINGS ITEM 29 CD <br /> DRAWINGS ITEM WATER CLOSET FT :' 2" 1/2" I I PRIOR TO BIDDING AND CONSTRUCTION/ NOTIFY ARCHITECT (ENGINEER) OF ANY PLAN VIEW 2 ❑ N <br /> DISCREPANCIES AND/ OR CONDITIONS OTHER THAN THOSE SHOWN, <br /> 29 URINAL FV 2" 1 1/2" I /4" I I ° ° ❑ <br /> S-1 STERLING 24x21 17 GA STAMPED STAINLESS STEEL SS SINK W JDP 35 DRAINS, REFER TO ARCH DRAWINGS URINAL FT 2" 1 1/2" 1/2" ❑ <br /> / LAV 2" 1 1/2" 1/2" 1/2" 14) WHERE WATER AND SEWER PIPES ARE RUN IN THE SAME TRENCH 2 � <br /> SOUTHHAVEN KOHLER K-15171-F-CP SINGLE LEVER FAUCET & HOSE. ADA COMPLIANT FOR ADA MOUNTING HEIGHT, FOR W <br /> 11403-NA WITHOUT AERATOR, BRASSCRAFT KTSR17FC STOPS & B-16A SUPPLY MOUNT GD-1 ON SINK BAR SINK 2" 1 1/2" 1/2" 1/2" a) THE BOTTOM OF THE WATER PIPE AT ALL POINTS SHALL BE AT LEAST 12" ABOVE 12"MIN REM❑ GRATE <br /> HOSES PLUMBEX 2002 P-TRAP & ANGLE STOP INSULATION. CLASSROOM SINK 2" 1:11/2" 1/2" 1/2" ACCESS S A CLEAN <br /> THE TOP OF THE SEWER, DOME STRAINER <br /> GD-1 INSINKEARATOR 3/4 HP GARBAGE DISPOSAL, SS BODY AND BLADES, INTEGRAL KITCHEN SINK 2" 1:11/2" 1/2" 1/2" ,b) THE WATER PIPE SHALL BE PLACED ON A SOLID SHELF EXCAVATED AT ONE SIDE <br /> EVOLUTION DISHWASHER CONNECTION, 110V 1PH. COLOR BY ARCHITECT. MOP SINK It' 2" C/4" C/4" OF A COMMON TRENCH, <br /> ESSENTIAL TRAP PRIMER ❑ 1/2" ❑ <br /> AD-1 KARP DSC 214M GRAY PRIMERED ACCESS DOORS - SEE DRAWINGS FOR TYPE OF LOCKING PAINT TO MATCH FD ,12" 2" 1 1/2" 11 11 14) ALL SINKS MUST BE EQUIPPED WITH HOT AND COLD WATER DISPENSED FROM MIXING FLUSHED WITH FLOOR <br /> MECHANISM. UNLESS OTHERWISE NOTED, FURNISH DOORS WITH SLOTTED ARCHITECTURAL SURFACES. FL P I' 2" I I I FAUCETS, TEMPERATURE AT POINT OF DELIVERY SHALL BE 115 DEF OR LESS, G P BETWEEN SINK <br /> 1/4" LOCKS. MIN SIZE IS 12x12. COLOR BY ARCHITECT. G.C. TO GROUT I/ <br /> FLFLOOR SINK I t' I t' 1 1/2" I I I I OOR SINK 2" 2" 1 1/2" I I I I 15) NO VENT PIPE SHALL TERMINATE CLOSER THAN 25 FT. FROM ANY OUTSIDE OR W H - 1 T H R U 3 M ❑ U N T I N G 6 & FLOOR <br /> TP-1 PPP, INC. PROVIDE DU- ACCESSORY WHERE PRIMER IS USED FOR MORE THAN ONE MOUNT IN WALL BEHIND SHOWER I IRES. 2" 1 1/2" 1/2" 1/2" HVAC INTAKE AIR, DETAIL PD SECTION <br /> PR-500 PRIME DRAIN. AD-1 WITH SOV. EYEWASH 2" 1:11/2" 1/2" 11 <br /> RITE 16) PROVIDE BACKFLOW PREVENTION DEVICE AS REQUIRED BY CODE OR LOCAL <br /> GOVERNING AUTHORITY, CONTRACTOR SHALL VERIFY THIS WITH GOVERNING FS - 1 MOUNTING 3 <br /> FD-1 ZURN ZN415 TYPE B STRAINER FLOOR DRAIN, 2" OUTLET, TRAP PRIMER FITTING. JURISDICTION AND INCLUDE COST OF SAME IN BID, WATER SERVICE & SANITARY <br /> REF-1 LSP PRODUCTS METAL BOX, WHITE W/1/4" COMPRESSION STOP WITH 1/4 TURN BALLIT SHALL BE THE RESPONSIBILITY OF SERVICE IF PLACED IN THE SAME DETAIL <br /> OB-509T VALVE FOR REFRIGERATOR ICE MAKER. 17) ALL VENTS AND PIPING THRU ROOF SHALL BE FLASHED AND COUNTER FLASHED AS CLEAR TOP OF TRENCH SHALL HAVE A LATERAL by HILTON" <br /> THE MECHANICAL, PLUMBING, ELECTRICAL REQUIRED TO MAKE WATERTIGHT PER ROOFING MANUFACTURER'S DETAILS, PROJECTION CLEARANCE OF 30" MIN. <br /> HB-1 ZURN LOOSE KEY HOSEBIB. MOUNT ON WALL. INSTALL AND GENERAL CONTRACTOR TO EXAMINE 30// MI WATER <br /> Z1341-P12-RK VACUUM BREAKER. THESE DRAWINGS AND CORRESPONDING 18) ALL FLOOR DRAINS REQUIRE TRAP PRIMERS. PRECISION PLUMBING PRODUCTS AS PROVIDE SLEE 2" <br /> I—� <br /> WH-1,2 STATE 199 MBH INPUT 100 GAL HOT WATER HEATER COMPLETE WITH ANODE, SCHEDULED ( MOUNT WHERE SHOWN,) CLEAR AROUND PIP <br /> SUFlOO199NEA CONTROLS, 120V POWER WIRING, 97% THERMAL EFFICIENT. SPECIFICATION SECTIONS FOR WORK TO ¢ <br /> WH-3 STATE 400 MBH INPUT 119 GAL HOT WATER HEATER COMPLETE WITH ANODE, BE PERFORMED BY OTHER TRADES SHOWN 19) PROVIDE THE BETWEEN DOWNSPOUTS AND SITE DRAINAGE DOWNSPOUT CONNECTION z <br /> T WITH CLEANOUT, (REFER TO GRADING PLAN FOR DOWNSPOUT AND AREA DRAIN 1121' BALL VALVE 0 <br /> SUF11940ONEA CONTROLS, 120V POWER WIRING, 95% THERMAL EFFICIENT. [IN THESE DRAWINGS, LOCATIONS), O <br /> ET-1 WESSELS FX10 HYDRO-PNEUMATIC TANK FOR POTABLE WATER, VERTICAL MOUNT, OPEN TREN // 12// MI4, Q <br /> NON-ASME, 10 GAL. 20) HOSE BIBBS SHALL BE PROTECTED BY APPROVED NON-REMOVABLE BACKFLOW 6 fi1.I:N :'a C MI U <br /> TRV-1 ARMSTRONG DIGITAL RE-CIRCULATING VALVE W/ 3" NPT CONNECTIONS. HOT WATER SET AT 120 DEG F MAX PREVENTION DEVICES, SLOPETNOT SEWER <br /> TRAP PRIMER FITTING <br /> DRV-80R-BS-D TO GUEST ROOMS IS TO BE MIXED TO 120°F THROUGH RECIRCULATING TEMPERATURE 21) PROVIDE THRUST BLOCKS PER CODE IF RUBBER GASKETED JOINT FIRE SERVICE 1 IN 2, PIPE MUST BE 2-4 FLOOR DRAINS <br /> S VALVE FOR DELIVERY TO POINT OF USE. PIPING IS PROPOSED, FIRE LINE SHALL HAVE A MINIMUM 2" CLEARANCE ALL CONCRETE & SLEEVE PLACED ABOVE THIS LINE AD-1 <br /> WS-1,2 & BT-1 - WATER SOFTENERS AND BRINE TANK FURNISHED BY OWNER. CONTRACT❑R SHALL INSTALL OWNER AROUND TO CONCRETE AT RISER INSIDE OR EXTERIOR TO BUILDING, FULL WIDT 2 12x12 MIN <br /> FURNISHED WATER SOFTENER CONSISTING OF 2-10 CU FT FIBERGLASS RESIN TANKS WITH 6 CU FT OF RESIN IN EACH, 6// a,MIN. `� 3/8// CU LINES <br /> j\ <br /> MINIMUM 8-POINT WATER DISTRIBUT❑R IN GRAVEL BED, 24 VOLT FULLY AUTOMATIC MASTER/SLAVE CONFIGURATI❑N WATER 22) PROVIDE STAINLESS STEEL FLEX CONNECTIONS FOR SUPPLY AT WATER CLOSETS,/ FOR CASES OF LESS THANT❑ TRAP PRIMER <br /> VALVES. UNITS ARE EQUIPPED WITH THE F❑LL❑WING: ANGLE STOPS TO BE BRASS, 3'-0", OTHERWISE USE ri <br /> FITTING ❑N FD-1 Z <br /> 1. LCD DISPLAY, NIT LE S N T LESS STEPPED FOOTING <br /> 2, INTEGRAL 365 DAY T I M E C L❑C K, 23) ALL TUB/ SHOWER OPENINGS SHALL BE RODENT PROOF WITH 1' CEMENT COVERING THAN 18/' THAN 18// <br /> 3, BUILT IN CONTROLLER MONITORING WATER GRAINS OF HARDNESS FROM PROGRAMMABLE SETP❑INT AND REGENERATING IN AN APPROVED MANNER, 0W <br /> SOFTENER WHEN SETPOINT IS EXCEEDED AND SAMPLING FOR OPTIMUM ❑PERATI❑N. > <br /> vi 4, LEAD/LAG REGENERATION VIA MASTER/SLAVE CONFIGURATI❑N, MASTER SLAVE WIRING SHALL BE BY RJ45 C❑NNECTI❑NS 24) PLUMBING CONTRACTOR TO VERIFY LOCATION OF WATER CLOSET WASTE WITH PIPE THRU FOOTING TRAP PRIMER 4 Q <br /> a WITH PHONE MODEM C❑NNECTI❑N, EXISTING CONCRETE FLOOR JOIST LAYOUT, LOCATE WATER CLOSET TO CAUSE NO <br /> -' 5, 11OV/24V TRANSFORMER, INTERFERENCE TO CONTINUOUS FLOOR JOIST FRAMING, <br /> DETAIL <br /> 6, TANKS SHALL BE SET ON FIBERGLASS BASE INDEPENDENT OF THE BRINE TANK. BRINE TANK SHALL BE POLYPROPYLENE DETAIL POY.1 <br /> ¢ WITH LID, 1000# MINIMUM CAPACITY, 25) ALL PIPING SHALL BE CONCEALED WITHIN BUILDING COMPONENTS, AND SHALL NOT N <br /> v BE EXPOSED TO PUBLIC VIEW EXCEPT IN BASEMENT AND ON SECOND FLOOR <br /> PLUMBING NOTES: WHERE THERE ARE NO CEILINGS, NOTIFY OWNER AND ARCHITECT WHEN <br /> o CONCEALING SUCH CAN NOT BE ACHIEVED, 4"CW HEADER 0 <br /> ALL WORK SHALL CONFORM TO THE FOLLOWING CODES <br /> 26) PROVIDE (MIN,) 12"x12" ONE-HOUR RATED ACCESS PANEL (WALL OR CEILING) AS J <br /> O REQUIRED FOR ACCESS TO PLUMBING VALVES, ETC, 4"C W HEADER <br /> 0 2016 CBC 2016 CPC 3"CW IN AND OUT ] W <br /> � <br /> 2 016 CMC 27) ALL DOMESTIC WATER VALVES UP TO AND INCLUDING OPEN 2 INCHES IN SIZE T❑ EACH W S- <br /> SHALL BE MADE OF BRASS OR OTHER APPROVED MATERIALS, USE OF GATE REDUCE AFTER <br /> E 2016 CEC BV BV BV BV <br /> VALVES IS PROHIBITED UNI❑N ONLY <br /> WS-1 -UN -UN -UN -UN BV� <br /> CONTRACTOR SHALL KEEP ALL INSTALLATI❑N INSTRUCTIONS FOR PLUMBING FIXTURES, ACCESS DOORS, SEALING MATERIAL, FIRE 28) DRAINAGE CONNECTION SHALL NOT BE MADE INTO DRAINAGE PIPING SYSTEM WS-2 2-1/2"CW BYPASS 6� r <br /> STOPPING, ETC, ONSITE IN WATERPROOF POUCHES FOR THE INSPECTING AUTHORITY FOR THEIR REVIEW, 110 1100 <br /> WITHIN EIGHT (8) FEET (VERTICAL AND HORIZONTAL) OF ANY VERTICAL OR <br /> VOLTS VOLTS - NC <br /> =3PLUMBING CONTRACTOR SHALL SUBMIT 7 SETS OF SUBMITTALS FOR REVIEW AND COMMENT BY THE ENGINEER AND ARCHITECT HORIZONTAL CHANGE OF DIRECTION OF A STACK CONTAINING SUDS-PRODUCING <br /> o FIXTURES, 3/4" BRINE FILL � <br /> 0 ❑F RECORD FOR THE FIXTURES LISTED AND THE MATERIAL T❑ BE USED AND INSTALLED ❑N THIS PROJECT AND SHALL MAKE 3/4" PVC DRAIN �' AND SIPHON LINE z <br /> THE APPROPRIATE CHANGES AS DIRECTED BY THE ENGINEER AND ARCHITECT AT NO ADDITIONAL COST TO THE OWNER, 29) PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH ON GRADE CONCRETE LINE TO FS-1 FOR REGENERATI❑N <br /> MATERIALS FLOORS, -SLEEVES SHALL BE SIZED SO THAT THERE IS A MINIMUM OF ONE HALF 3/4' PVC DRAIN <br /> o COLD AND HOT WATER (1/2) INCH CLEARANCE AROUND THE PIPE AND OR INSULATION, LINE TO FS-1 0 <br /> (' TYPE 'L' COPPER ABOVE GROUND AND TYPE 'K' BELOW, FURNISH SHUTOFF VALVES WHERE SHOWN, SHUT OFF VALVES <br /> 30) THE BACKFLOW ASSEMBLY AND DEVICE SHALL BE PROTECTED FROM FREEZING BY A zo <br /> o SHALL BE BALL TYPE WITH TEFLON SEATS, STAINLESS STEEL BALL, AND DOUBLE ❑-RING STEM 1/4 TURN, VALVES TO BE <br /> METHOD ACCEPTABLE TO THE LOCAL JURISDICTION, <br /> RATED FOR WOG SERVICE, PR❑VIDE DIELECTRIC UNI❑NS AT ALL DISSIMILAR METAL C❑NNECTI❑NS, INSULATE HOT WATER U <br /> SUPPLY AND RETURN LINES W/1" FIBERGLASS ASJ MEETING THE REQUIREMENTS OF T-24 MANDATORY FEATURES, <br /> 31) PROVIDE FIRE SPRINKLERS PLANS FOR REVIEW AND APPROVAL TO 0 <br /> o "MODESTOREGIONAL FIRE AUTHORITY FIRE PREVENTION BUREAU". AFTER REVIEW <br /> SCH 40 CPVC BELOW GRADE OUTSIDE, SIZE AS INDICATED ON THE DRAWINGS. CONTRACTOR SHALL COORDINATE HIS WORK U _ <br /> �- WITH OTHER TRADES, CONTRACTOR SHALL DISINFECT WATER LINES PER AWA GUIDELINES AND PROVIDE THREE COPIES FROM RESUBMIT TWO (2) COPIES OF REVISED PLANS TO THE MODESTO REGIONAL FIRE 3/4" BRINE Z ~ <br /> AN INDEPENDENT TEST LAB. WATER SHALL BE TESTED FOR WATER BORNE BACTERIUM, SPORIDIUM AND OTHER PATHOGENS AT AUTHORITY FIRE PREVENTION BUREAU FOR RECHECK, FS-1 OVERFLOW - RUN J <br /> -d THE TIME OF OCCUPANCY AND CERTIFY THE SYSTEM PASSED THESE TESTS, TO FS-1 <br /> En RESIN TANK - 21"OX72"TALL - ANCHOR <br /> =3 TEST WATER LINES AT 1,5 TIMES WORKING PRESSURE FOR LEAKS, NOT TO EXCEED 100 PSIG, HOLD PRESSURE FOR 24 HOURS, TO WALL PER WH-1 THRU 3 ATTACHMENT <br /> DETAIL 5/PO REVISIONS: <br /> SEWER AND RWL'S - ABS PIPE AND FITTINGS ABOVE AND BELOW GRADE, CI PIPE WITH ESCUTCHEONS WHERE PROHIBITED BY 110 110 <br /> CODE AND THE LOCAL JURISDICTION. CLEAN❑UTS SHALL BE PROVIDED EVERY 100 FT AND AT EACH CHANGE OF DIRECTI❑N FLUE PVC FLUE PVC 1"AIRGAP TYPICAL AT Q HILTON 10/18/2018 <br /> GREATER THAT 909. USE OF ABS PIPE IS LIMITED TO BUILDINGS 2 OR LESS ST❑RIES IN HEIGHT AND CANNOT BE USED ALL INDIRECT <br /> WITHIN FIRE RATED ASSEMBLIES, ALL SEWER LINES SHALL BE SLOPED AT A MINIMUM OF 1/4" PER 1'. OF-1 CONNECTIONS <br /> SET ROOF DRAIN LEVEL WITH SINGLE PLY ROOFING - <br /> VENT LINES - SEE SEWER LINES FINISHED ROOF TAPER PER ROOFING <br /> PANUFACTURER'S <br /> C SINGLE PLY ROOFING - TAPER PER SPECIFICATIONS <br /> ROOFING PANUFACTURER'S EXTEND 3' AFR EXTEND 3' AFR <br /> SPECIFICATIONS TOWARDS DRAIN WS - 1 ) 2 PIPING DIAGRAM 8 <br /> � HVAC CONDENSATE DRAIN LINES - TYPE 'M' COPPER PIPE AND FITTINGS INSIDE BUILDING AND SCH 40 PVC PIPE OUTSIDE <br /> BUILDING, PR❑VIDE CLEANOUT AT EACH CHANGE OF DIRECTI❑N AND AT C❑IL CONNECTION, SLOPE LINES AT 1/8" PER 1'. CEC 110.3(C)5.C,D 12"TALL <br /> 1-1/2"GAS TO 1/2" AIR BLEED (NOT DETAIL PO <br /> TEST SS AND RWL DRAIN LINES PER SECTI❑N 723.1 AND 11062,2 RESPECTIVELY, TEST CONDENSATE DRAIN LINES USING 2"GAS EACH WATER REQUIRED ID HWCP-1 IS <br /> SECTI❑N 1106,22 METAL ROOF DECK - AS GAS GAS HEATER MOUNTED VERTICALLY) AND <br /> STRUCTURAL DRAWINGS I � NOTES: <br /> PUMP ISOLATION VALVES 1. ALL PIPING TO EACH WATER SOFTENER SHALL CONTAIN <br /> v GAS DECK CLAMP W/BOLTS - INSTALL <br /> " PER ROOFING MANUFACTURER'S < OSA INTAKE a EXP-1 WITH HB-2 FOR DRAIN THE SAME NUMBER OF FITTINGS, LENGTH OF PIPE AND <br /> c- 5 PSI SERVICE - 2-1/2 AND SMALLER SHALL BE SCH 40 GI SCREWED PIPE AND FITTINGS, 3 AND LARGER SHALL BE SCH SPECIFICATIONS Ron ATTACHMENT TO METAL JOIST FROM ROOM - LD 10 GALU " " NIPPLES TO PR❑VIDE BALANCED FLOW THRU SYSTEM, <br /> 40 WELDED PIPE AND FITTINGS. EXPOSED PIPE SHALL BE GALVANIZED, BURIED PIPE SHALL BE COVERED WITH X-TRU COAT. PIPE CLEVIS HANGER W/1/2' SOV 3 HW/2 CW TO <br /> i 4 BAND CLAMP AT ALL THREAD ROD (ATR) TYPICA2. COLD WATER HEADERS TO BE PIPED FOR REVERSE FLOW <br /> ¢ ALL PIPE INSIDE BUILDING SHALL BE WELDED, DRAIN CONNECTION SEISMICALLY BRACED MIXING VALVE TO EQUALIZE PRESSURE DROPS. <br /> 7" WC SERVICE - SCH 40 GALVANIZED IRON PIPE AND FITTINGS OUTSIDE BUILDING AND SCH 40 BLACK IRON PIPE INSIDE 3"HW HEADER DRV-1. RED PROJECT # 18050 <br /> V 4 BAND CLAMP AT S❑�/ 3"SCW FROM <br /> BUILDING, PAINT WHERE EXPOSED TO INTERI❑R FINISHES. ELBOW WITHNP ORT L3 69 a SOV BOOSTER HILTON # 18-428ND <br /> Q ELBOW HWCP-1 GAS LINE - SEE PLAN FOR <br /> TEST 7-11" WC GAS AND LPG LINES USING AIR AT 15 PSIG. OBSERVE FOR 24 HOURS FOR LEAKAGE, TEST ALL GAS LINES 3"CW HEADER SYSTEM SIZES -TYPICAL. PIPE SHALL PLANNING # SPR-18-102 <br /> o WITH HIGHER PRESSURES THAN 11" WC AT 1.5 TIMES WORKING PRESSURE, MINIMUM PRESSURE OF 50 PSIG. HOLD TEST FOR 24 SET ROOF DRAIN 2' BELOWRD I SINGLE <br /> TAPER PPLY <br /> ER ROOROOFING - 6�) BV CS 3/4" HWR BE GALVANIZED ON THE PERMIT # - <br /> HOURS. FINISHED ROOF PANUFACTURER'S a WH-1 WH-2 HOSEBIBB OUTSIDE OF PIPE ONLY, <br /> SINGLE PLY ROOFING - TAPER SPECIFICATIONS „ LD J❑BNS❑N A419 SUITABLE FOR GAS USE. APN 196-270-23 <br /> PER ROOFING PANUFACTURER'S C—I CSI CONTROLLER SET # <br /> FIXTURES SP CIFICATIONS UN BV AND 120 DEG F, <br /> o ROUGH IN ALL ACCESSIBLE FIXTURES PER THE DETAILS FOUND IN CBC CHAPTER 11, THE ARCHITECTURAL DRAWINGS AND LOCAL �� I��� 1"T&P RE IFF _ UN BV C 110 VOLTS K❑S❑ 316E EARTHQUAKE VALVE DATE: 11.12.18 <br /> Q <br /> CODE REQUIREMENTS. NOTIFY ARCHITECT IN WRITING OF CONFLICTS, SEE PLAN FOR 1"T&P RE IEE - DRAWN: NR <br /> SUBMITTALS LOCATION SEE PLANS FE 1"T&P RELIEF - SEE <br /> PR❑VIDE SEVEN SETS OF SUBMITTALS FOR REVIEW. STRMETAL UCTURAL ODRAWINGS LO ATI❑N PLANS FOR L❑CATI❑N CHECKED: GD <br /> ❑~ 110 ❑~ 110 <br /> DECK CLAMP BOLTS <br /> I STALL PER/ROOFING VOLTS VOLTS <br /> o INSTALLATION MANUFACTURER'S ROD ATTACHMENT a 2"CW TO METER ASSEMBLY BY OTHERS <br /> SPECIFICATIONS Q C W <br /> BRACE ALL PIPE AND DUCT SYSTEMS PER SMACNA SEISMIC RESTRAINT GUIDELINES INCLUDING CHANGES OF DIRECTI❑N AND TO METAL JOIST LD SIV C—I SIV CSI <br /> CHANGES IN ELEVATI❑N OF MORE THAN 10', 4 BAND CLAMP AT PIPE CLEATS HANGER W/1/2' UNBV -3 UN BVSHEET TITLE: <br /> DRAIN CONNECTION SALL THREAD ROD (ATEISMICALLY BRACED R) kj � <br /> 399 MBH LJ 399 MB T❑ OTHER GASJJ4UNI�STIRUT AND CLAMPInK DRIP LEG DRA N IBB APPLIANCES ATACHED TO WALL - , <br /> _ (PVC INSTALLATION 4 BAND CLAMP AT SEE DETAIL + PLUMBING SCHEDULES <br /> INSTALLATION OF CPVC FOR NEW AND REPLACEMENT SYSTEMS MUST COMPLY WITH THE REQUIREMENTS AS STATED IN CHAPTER ELBOW w/SUPPORT -TYPICAL ALL DETAILS, AND NOTES <br /> Qj WITHIN 6'OF <br /> Ln 6 AND INSTALLATI❑N STANDARDS IAPM❑ IS-20-2005, ALL PROCEDURES MUST BE FOLLOWED FOR FLUSHING AND WORKER ELBOW DETAILS <br /> SAFETY MEASURES. INCLUDED ARE THE PENALTIES AS STATED ON CHAPTER 6 (g), ANY CONTRACTOR OR SUBCONTRACTOR 120°F 18"MIN <br /> Q) 9 III III III III III <br /> FOUND TO HAVE FAILED TO COMPLY WITH THE VENTILATI❑N GLOVE OR FLUSHING REQUIREMENTS OF SECTI❑N 1.2.2 OF ROOF DRAIN AND OVERFLOW DETAIL 11 3"HW <br /> o APPENDIX I OF THIS CODE, INSTALLATI❑N STANDARDS FOR CPVC SOLVENT CEMENT HOT AND COLD WATER DISTRIBUTION DETAIL TO BLDG. <br /> o SYSTEMS. IAPMO IS-20-2005 SHALL BE SUBJECT TO THE PENALTIES ON HEALTH AND SAFETY CODE, DIVISI❑N 13, PART 15 P O <br /> CHAPTER 6 SECTION 17995, W H - 1 , W H - 2 P I P I N G <br /> 0 DRV-1 z"CW 1 OV POLYETHYLENE GAS PIPE <br /> c IN ADDITI❑N IF DURING THE CONDUCT OF ANY BUILDING INSPECTI❑N, THE BUILDING OFFICIAL FINDS THAT THE VENTILATI❑N DETAILPQ 1#ZINC ANODE ATTACHED TO <br /> Q AND GLOVE REQUIREMENTS OF SECTION 1.2.2 OF APPENDIX I OF THIS CODE, SPECIAL REQUIREMENTS FOR CPVC INSTALLATI❑N 140°F 18/' GALVANIZED STEEL PIPE WITH <br /> a� WITHIN RESIDENTIAL BUILDINGS ARE BEING VIOLATED, BUILDING OFFICIAL SHALL CITE THE CONTRACTOR OR SUBCONTRACTOR 3"HW NOTES: BRASS CLAMP AND #8 COPPER <br /> c <br /> FOR THE VIOLATION UNDER THE CALIFORNIA PLUMBING CODE, HWR 1. ALL PIPING TO EACH WATER HEATER SHALL CONTAIN WIRE SHEET NO.: <br /> THE SAME NUMBER OF FITTINGS, LENGTH OF PIPE AND <br /> NIPPLES TO PR❑VIDE BALANCED FLOW THRU SYSTEM, GAS RISER PIPING <br /> 9 <br /> 2. HOT AND COLD WATER HEADERS TO BE PIPED FOR <br /> (`-' REVERSE FLOW TO EQUALIZE PRESSURE DROPS, <br /> SET WATER HEATERS TO MAINTAIN 125°F LEAVING WATER DETAIL PO PO <br /> TEMP. <br />