Laserfiche WebLink
1 <br /> DIMMING ROOM . U <br /> CONTROLLER , Uj <br /> WITH CATS INPUTS FOR <br /> LIGHT SWITCHES, LIGHT FIXTURE SCHEDULE - HOTEL <br /> MOTION SENSORS, <br /> DAY LIGHT PHOTOCELL SKETCH TYPE LAMPS DESCRIPTION MANUFACTURER'S NO. DRIVER VOLTAGE WATTAGE <br /> N LINE VOLTAGE U <br /> INPUT LEDs RECESSED NOMINAL 4" APERATURE <br /> 20001m DOWNLIGHT, WHITE PAINTED FLANGE. LUMINAIRE <br /> 03 3000K #CLI—OOTHHL03 0-10V 120/277 17 Q <br /> / RED INC ARCHITECTS <br /> LEDs SURFACE MOUNT 6" CYLINDER 20952STREET, MODESTO, CA 95354 <br /> 120v LUMINAIRE <br /> TO SECOND TO SECOND [J L-05 <br /> 25001m #CLI-00THHL05 0-10V 21 <br /> O SWITCH SENSOR 3000K 120/277 SEAL: <br /> Q LEDs SURFACE MOUNTED LOW PROFILE <br /> W 9951m LINEAR LED FLOODLIGHT. LUMINAIRE 0-10V 120/277 15W/FT <br /> _ f ESS/ <br /> N 3000K #CLI-00THHLO8 o C.s Ey <br /> z OUTLET LEDs MONORAIL TRACK WITH ADJUSTABLE Exp. s'43 i s <br /> a L-09 <br /> TRACK HEAD WITH CURRENT LIMITER. 0-10V 120 277 12.5W FT <br /> CONTROLLER7501m LUMINAIRE / /CLI-00THHL09 <br /> W /r 3000K # qr FCTR�� <br /> o LINE VOLTAGE FCF CA►-�F� <br /> CONTROL & LEDs RECESSED 24x48 LED TROFFER. <br /> 1 57001m <br /> a 0-10V DIMMER LUMINAIRE <br /> N CONTROL P 3000K #CLI—OOTHHL1 1 0-10V 120/277 46 <br /> WALL MOUNT CEILING CEILING <br /> SWITCH WITH OCCUPANCY PHOTOELECTRIC LEDs SURFACE MOUNTED LED LUMINAIRE <br /> X ON/OFF POWER SENSOR SENSOR P 3 40001m WRAPAROUND TROFFER. 0-10V 120/277 48 CONSULTANT: <br /> o AND RAISE CLI—OOTHHL13 <br /> M LOWER CONTROL 3000K # <br /> Z <br /> Z LEDs RECESSED NOMINAL 4" LUMINAIRE HCS. <br /> N <br /> P 9 <br /> 10001m APERATURE DOWNLIGHT, CLEAR 0-10V 120/277 9 <br /> W 3000K SELF—FLANGED. #CLI—OOTHHL19 Engineering <br /> v=i 50 years <br /> N LEDs 8" INGROUND UPLIGHT 4512 Feather River Dr#F,Stockton,CA 95219 <br /> —20 LUMINAIRE <br /> L 30001m 0-10V 120/277 35W 209-�,78-827o I www.hcs-eng.com <br /> 3000K #CLI—OOTHHL20 <br /> ®Richard C.Smith.PE richardChcs-eng.com <br /> „ 13 Bhupendra Patel,PE bhupendmahcs-eng.com <br /> LEDs 48 SURFACE MOUNT LED WITH LUMINAIRE ❑Elizabeth Aguilar elizabeth@hcs-eng.com <br /> L-23E 35001m EMERGENCY BATTERY BACKUP STEPPED 120/277 36 <br /> 0-10V DIMMING AND OCCUPANT SENSOR #CLI—OOTHHL23 PROJECT#2018.338 <br /> LIGHT FIXTURES 3000K <br /> LEDsLINEAR DIRECT SUSPENDED. LUMINAIRE <br /> E-25 10001m CLI—OOTHHL25 0-10V 120/277 8.4/FT <br /> LIGHTING CONTROL DETAIL 3000K # <br /> NTS LEDs LARGE DECORATIVE PENDANT LUMINAIRE <br /> PA-JOO 16001m TRIAC 120/277 18 <br /> 2700K #CLI—OOTHHPA300 <br /> LEDs SMALL DECORATIVE PENDANT. <br /> PA-J01 16001m LUMINAIRE TRIAC 120/277 18 <br /> LIGHTING CONTROLS 2700K #CLI—OOTHHPA301 <br /> LEDs SMALL DECORATIVE PENDANT. LUMINAIRE <br /> PA- <br /> jo� <br /> 3601m TRIAC 120/277 4 <br /> LINE VOLTAGE (HOT, SWITCH HOT, NEUTRAL, GROUND & 3#14 DIMMING) 2700K <br /> #CLI—OOTHHPA303 by HILTON" <br /> —D— 0-10V CONTROL CABLE (3#14) LEDs LARGE CEILING MOUNTED LIGHT <br /> —N— CAT-5 CONTROL CABLELUMINAIRE <br /> PA—J06 65001 m #CLI—OOTHHPA306 0-10V 120/277 83 <br /> 3000K a <br /> US CEILING MOUNT OCCUPANCY SENSOR Z <br /> LEDs SMALL CEILING MOUNTED LIGHT. o <br /> PC PHOTOCELL PA-301 33001m LCMIN01RE 0THHPA307 0-10V 120/277 42 a <br /> D DIMMING SWITCH # <br /> 3000K 0 <br /> DRC DIMMING ROOM CONTROLLER LINEAR DIRECT SURFACE MOUNT. <br /> LEDs <br /> $R OUTLET RELAY 20A RATED PA-JO9 5001m LUMINAIRE 0-10V 120/277 18 <br /> NOTES: 3000K #CLI—OOTHHPA309 <br /> 1. FOR SUBMITTAL INCLUDE FACTORY CONTROL DRAWINGS. LEDs LED STRING LIGHT LUMINAIRE <br /> 2. CONDUCT A CONTROLS PRE—CONSTRUCTION MEETING WITH CONTROLS STARTUP ED 4701m #CLI—OOTHHED 0-10V 120 12.5W/F7 Z <br /> TEAM. PROVIDE AGENDA AND ATTENDEES AS A SUBMITTAL. INCLUDE DEVICE I.D. 2700K • <br /> TAGS, PROGRAMMING, CABLE ROUTING, PROGRAM AND TIME SCHEDULES AND DATE 0 W <br /> OF PROGRAMMING AND TESTING. <br /> cli <br /> 3. CONTRACTOR TO HAVE SYSTEM FACTORY SUPPORT FOR START UP, PROGRAMMING <br /> Q <br /> AND COMMISSIONING. VERIFY OPERATIONAL HOURS WITH OWNER PRIOR TO <br /> COMMISSIONING. W <br /> ¢ C H <br /> Z <br /> U <br /> C <br /> OW <br /> • <br /> Cn SEE ARCH. DRAWINGS & SPECSON HANGER WIRE <br /> W <br /> FOR"ANCHORAGE DETAIL.IL" <br /> CL FASTEN #12 SUSPENSION WIRE <br /> AT 2 DIAGONAL CORNERS OF PROVIDE 2 TAUGHT WIRES AT <br /> HOT EACH 4' LAY—IN FIXTURE & DIAGONAL CORNNERS FOR FIXTURES RECESSED FIXTURE FASTEN BAR HANGER <br /> o <br /> TO STRUCTURAL MEMBER THAT WEIGHS 56LBS OR LESS TO T-BAR CHANNEL � <br /> FASTENED TO BAR HANGER WITH SHEET METAL SCREWS. U) <br /> _ _ PROVIDE 4 TAUGHT SUPPORT (2 SCREWS PER END PER <br /> +' 2—GANG F 1 WIRES, ONE AT EACH CORNER SLIDE APART BAR HANGER Z <br /> 3 PLATE FOR FIXTURES THAT WEIGH HANGER) � <br /> AUTOMATIC SENSOR INTEGRAL EARTHQUAKE MORE THAN 56 LBS. ¢ <br /> I SWITCH CLIP. BEND OUT AS Q� <br /> v- REQUIRED TO ENGAGE T-BAR CHANNEL 0 <br /> MOTION L — JMAIN "TEE" RUNNERS. FASTEN FIXTURE TO MAIN Z <br /> L.- SENSOR 1/4" HOLE IN CLIP FOR RUNNER W/#8x1/2 SELF— 0 <br /> o TAPPING TEK SCREWS, ONE <br /> SUSPENSION RUNNERS AT EACH CORNER TRIM U <br /> U __ ACOUSTIC <br /> CEILING TILE o <br /> MANUAL <br /> 0 1 1 ON/OFF CEILING TILE N = <br /> ON OFF 1 1 SWITCH ,/ 0 Q <br /> a <br /> L AUTO/OFF L __J T—BAR LAY—IN FLUORESCENT 0 J <br /> SWITCH SWITCH <br /> v LIGHT FIXTURE <br /> Cn <br /> LIGHTS — INSIDE _j LIGHTS — OUTSIDE <br /> LAMPS EACH FIXTURE I LAMPS EACH FIXTURE REVISIONS: <br /> v <br /> MOUNTING DETAIL: LAY- IN FIXTURE MOUNTING DETAIL: RECESSED FIXTURE TYPE "B " Q2 HILTON 10/18/2018 <br /> E <br /> v, <br /> 3 ELEVATION SCHEMATIC DIAGRAM <br /> v <br /> L <br /> a� <br /> DETAIL: LIGHTING SWITCH STATI 0 N D A <br /> U <br /> N <br /> WOOD JOIST <br /> v <br /> GYP. BOARD CEILING i RED PROJECT # 18050 <br /> HILTON # 18-428ND <br /> SURFACE LIGHT FIXTURE <br /> PLANNING # SPR-18-102 <br /> o FASTEN FIXTURE TO WOOD PERMIT # — <br /> JOIST WITH #12x2" RHWS. <br /> (TOTAL OF 4 PER FIXTURE) APN # 196-270-23 <br /> a <br /> FIXTURE INSTALLED AT 900 TO JOISTS DATE: 11.12.18 <br /> DRAWN: BA <br /> a� <br /> CHECKED: RCS <br /> C- FASTEN WOOD BLOCKING TO 2"x6" WOOD BLOCKING <br /> WOOD JOIST USING #16d NAILS (TOTAL OF 2 PER FIXTURE) <br /> v (TOTAL OF 3 EACH END) SHEET TITLE: <br /> •v, ;~ 2"x6" WOOD JOIST FIXTURE SCEDULE AND <br /> LIGHTING CONTROL <br /> 3 FASTEN FIXTURE TO WOOD GYP. BOARD CEILING DETAILS <br /> CD BLOCKING WITH #12x2 RHWS SURFACE LIGHT FIXTURE <br /> o (TOTAL OF 4 PER FIXTURE) <br /> L <br /> FIXTURE INSTALLED PARALLEL TO JOIST <br /> a <br /> 3 MOUNTING DETAIL: SHEET NO.: <br /> v <br /> L <br /> SURFACE FIXTURE <br /> E003 <br /> E B <br /> FILE: K:\2018\301-400\RED Tru Hilton Lathrop\EO03.dwg Mar 05, 2019 — 5:27pm richard <br />