Laserfiche WebLink
CV <br /> V I <br /> I— <br /> TRESPA METEON <br /> PANELS WITH CLIPS , LLI <br /> OVER VAPORSHIELD 2x WOOD STUDS @ 16" <br /> MODIFIED BITUMEN�ROOFING HEATHER-RESISTIVE O.G. (REFER TO — <br /> OVER SHEATHING BARRIER SYSTEM - <br /> STRUCTURAL DRAWINGSPROVI / <br /> N JOINTS DAS SHOWN ON U <br /> SEE EXTERIOR <br /> AFT <br /> FIRE CAULKING AT ANNULAR SPACE <br /> ELEVATIONS - INSTALL <br /> INSULATION ON PAPER/ RAG IN5U <br /> PER MANUFACTURERSAS NOTED ON T-24 <br /> PIPE PENETRATIONS PER GBG SECTION SPECIFICATIONS RED INC ARCHITECTS <br /> -115 af U 20q.522.8g00 <br /> 1211 J STREET,MODESTO,GA 85354 <br /> z <br /> 31/2" SOUND BATT INSULATION ] <br /> p (UNFAGED) Lu <br /> D/ <br /> O0 2X WOOD STUDS AT 16" OG <br /> w > <br /> "LP FLAMEBLOGK PLUS" SEAL: <br /> 0 EXTERIOR SHEATHING <br /> Q WITH FIRE CAULKED <br /> ONE LAYER 5/8" TYPE 'X' GYPSUM <br /> WALLBOARD OR VENEER BASE 5/8" FIRE RATED GYPSUM ED C <br /> FIBERGLASS BATT INSULATION JOINTS S AR <br /> Q APPLIED PARALLEL WITH OR AT�RIGHT C� <br /> N - FILL ENTIRE JOIST SPACE BOAYZD TRESPA STARTER <br /> ANGLES TO EACH SIDE OF 2X WOOD <br /> Z �REDBUILT JOISTS SEE CLIP - INSTALL PER Q >J <br /> STUDS SPACED AT I6" OG WITH I I/4" MANUFACTURERS <br /> TYPE 'W' DRYWALL SCREWS 12" OG - THREE LAYERS OF 5/5" STRUCTURAL. SPEGFIGATIONS <br /> z �? STAGGER JOINTS EACH SIDE FIRE RATED GYPSUM BOARD -7/&" HAT CHANNELS AT 24" <br /> O O.G. CONTINUOUS 26 GA <br /> ANCHOR BOLT <br /> N TYPICAL OUTLET BOX FOR TELEPHONE GSM FLASHING . FASTENING PER REN. \P <br /> AND REGEPTAGLE (ONE ABOVE THE GL05URE AS STRUCTURAL DRAWINGS 03-31-21 <br /> Q OTHER) OR SINGLE RECEPTACLE - BASE LAYER 5/&^FtRE'RATED GYPSUM WALLBOARD APPLIED AT'RIGHT ANGLES TO 2x&J015T5 24"O.G.WITH 1-1/4" REQUIRED F \FO <br /> LOCATE IN SEPARATE STUD CAVITY TYPE w SLAYER 12^O.G. OFCA�- <br /> w - SECOND LAYER 5/8'FIRE'RATED GYPSUM WALLBOARD APPLIED AT'RIGHT ANGLES TO JOISTS WITH 2'TYPE W SCREWS <br /> Iy N? WITH MINIMUM HORIZONTAL 5PAGING TO 12"O.G. <br /> - Z BE 24" O.G. - BOXES TO BE METALIU THIRD LAYER 5/5"FIRE'RATED GYPSUM WALLBOARD APPLIED AT'RIGHT ANGLE5 TO JOISTS WITH 2-1/2"TYPE W <br /> 5LREW5 12"O.G.,HAT-SHAPED 115"RIGID FRAMING CHANNELS 24"O.G.APPLIED ATRIGHT ANGLE5 TO J015T OVER <br /> N 5/8" SOUND BOARD THIRD LAYER WITH TWO(2)2-1/2"LONG TYPE W SCREWS AT EACH JOIST. <br /> O FACE LAYER 5/6"FIRE RATED GYPSUM WALLBOARD APPLIED AT'RIGHT ANGLES TO FURRING GHANNEL5 WITH 1-1/6' 3 <br /> TYPE 5 SCREWS 12"O.G.HOOD JOISTS SUPPORTING 3/4"T46 EDGE PLYWOOD FLOOR APPLIED AT RIGHT ANGLES TO p <br /> nZ J0I5T5 WITH 8d NAILS b"O.G.AT J015T5 AND 12"AT INTERMEDIATE J015T5. <br /> p ELECTRICAL OUTLET BOXES AND SIMILAR BOXES FOR T.V., PHONE, CONSULTANT: <br /> x 1() ETG. IN PARTY WALLS MUST BE STEEL AND NOT OVER 16" 50. W SECOND LAYER JOINTS OFFSET 24"FROM BASE LAYER JOINTS.THIRD LAYER JOINTS OFFSET 12"FROM SECOND LAYER <br /> O <br /> A- <br /> INCHES. SUCH BOXES RE TO BE SEALED WITH 3M MPP-45 FIRE 0 JOINTS. 3 <br /> m BARRIER PUTTY PAD OR EQUAL. STAGK MULTIPLE BOXES O <br /> VERTICALLY WHEN ON SAME SIDE OF WALL. O [D <br /> z Q p FERE'RATING: I HR DESIGN: V311 <br /> 2q FIRE RATING: 2 HR DESIGN: GA-FC 5125 UL L556 X 25 <br /> Q INSTALL PER GA FILE NO. WP 3514 N S.T.G. RATING: - REPORT NO. - w S.T.G. RATING: - TESTING NO. : - <br /> w <br /> w <br /> 2 <br /> ONE HOUR FIRE RATED MALL 2 g 2HR FLOOR GE I L I NC ASSEMBL'I( EXTERIOR DOUBLE MALL © ENTR T" <br /> 45 41 37 33 SCALE: 1" = 1'-0" SCALE: I" = 1'-0" SGALE: 1" = 1'-0" <br /> I-HR INTERIOR OR EXTERIOR WALL. <br /> FINISH FLOOR - SEE FINISH 5/8" FIRERATED GYP. BOARD EACH <br /> SCHEDULE SIDE <br /> I" OYPORETE OVER 3/4" 5/8" FIRE RATED GYPSUM <br /> PLYWOOD - SEE STRUCTURAL BOARD TO UNDERSIDE OFFLOOR SHEATHING OR <br /> I I SOLID 2X BLOGKING <br /> TJI AS OCCURS - SEE I I <br /> STRUCTURAL DRAWINGSI I <br /> 2x WOOD STUDS � 16" <br /> TJI WEB STIFFENER - AS ____ O.G. (REFER TO <br /> STRUCTURAL DRAWINGS) <br /> REQUIRED I I <br /> A35 CLIPS - (1) EACH SIDE @ I <br /> EACH END OF BLOCK I <br /> -- KRAFT PAPER FACED <br /> 2 X BLOGKING AT EACH BATT INSULATION W/ <br /> VERTICAL INTERIOR "LP FLAMEBLOGK 'R-Iq INSULATION AS <br /> 2X NAILER PLYWOOD AS OCCURS AT NOTED ON T-24 <br /> SHEAR WALL PLUS" EXTERIOR 5/8" <br /> METAL STUDS @ 16" O.G. - SEE TUBE STEEL COLUMN WITHIN FIRE RATED GYP. SHEATHING WITH 10'1 <br /> 'REFLECTED CEILING PLAN WALL. SEE TABLE BELOW FIRE CAULKED <br /> BOARD EACH SIDE JOINTS <br /> PERPINDIGULAR CONDITION: SEE FIRE RE515TANCE CALCULATIONS BELOW. COLUMNS SHADED GRAY DO NOT COMPLY PROVIDE 2 BEADS OF <br /> FINISH FLOOR - SEE FINISH WITH SECTION -722.5.1(1) AND NEED 2 LAYERS OF GYPSUM BOARD, OR A UL TESTED MASTIC @ PERIMETER <br /> SCHEDULE INTUME5GENT PAINT COATING IN ADDITION TO THE LAYER OF GYPSUM BOARD. SEE WALL PLATES (TYP) <br /> SHEET Al2.3 FOR ALTERNATE PROTECTION. SEE DETAIL Ib/Al2.1 FOR FREE STANDING FINISH FLOOR d FINISH FLOOR S BASE AS by <br /> HILTON'" <br /> I" GYPO RETE OVER 3/4" COLUMN CONDITION. BASE AS SCHEDULED <br /> PLYWOOD - SEE STRUCTURAL SCHEDULED <br /> GI H55 G2 H55 G3 H% C4 H55 <br /> FIRE RESISTANCE CALCULATIONS <br /> TJI AS OCCURS - SEE TE8 SIZE 4x4x j 5x5 j bxbx j IOx1ox j FASTENCIN BPER <br /> K/Y + + + + STRUCTURAL DRAWINGS <br /> W EIGHT OF STEEL PER LINEAR L2 11 22.31 42.26 16.33 - - - - STRUCTURAL <OOT IN L55 <br /> 4 4 TJI WEB FILLER - AS'REQUIRED DRAWINGS z D EATED PERIMETER OF STEEL IN 16 20 24 40 <br /> NGHE5 <br /> D u <br /> _ METAL STUDS Q 16" O.G. - SEE h OTAL THICKNE55 OF GYP.BD.IN I I ONGb25 Ob25 <br /> _ _ -REFLECTED GEILING PLAN HES(FOR 3HR OR LESS) n� LL <br /> __ _= TOTAL WEIGHT OF STEEL AND V J <br /> SYR BD. W+SOhD/144 11.126 2q.314 41.465 &5.011 3 <br /> 2 LAYERS 5/8" FIRE RATED p <br /> GYPSUM BOARD OVER 1/2" W/D =3b5 0.161 I,IICI 1.161 Lgob <br /> Q RESILIENT CHANNELS 12" O.G. <br /> FIRE-RESISTANCE IN MINUTES J <br /> PERPENDICULAR TO TRUSSES - 3OhfkW)n1�O•-� lo.lgo a63a1 61.154 llsoa Q <br /> m SEE AOII FOR ADDITIONAL 1 <br /> FL INFORMATION YR= E RESISTANCE IN HOURS Lno 1443 1.128 1.182 M FIRE'RATINO: N/A DESIGN: GBG TABLE -7.21.1 (14-1.3) <br /> o PARALLEL CONDITION: 1n•+1n' In'+1n• 5/6• 5/6• I 26 <br /> Jl � 1317, � s � ev• � az S.T.G.�RATING: 55+ TESTING NO. : N/A <br /> MIN. MIN. MIN. MIN. <br /> 46 42 38 34 SOFFIT BULKHEAD AT JOIST 30 1 HOUR FIRE RATED GOLUMN- I N HALL 26 INTERIOR DOUBLE MALL © ENTRY O �, <br /> SGALE: 1" = 1'-0" SCALE: 3" = 1'-0" O <br /> N GUEST ROOM <br /> s ONE GOAT SYSTEM - 2x STUDS @ 16" O.G. PER Q <br /> 3/8" GEMENT PLAN <br /> PLASTER OVER MINERAL FIBER INSULATION <br /> METAL LATH OVER - FILL ALL VOIDS nn�� <br /> I/2" INSULATION FINISH FLOOR d BASE ASC-) BOARD <br /> o <br /> HI 2 LAYERS 1/2" FIRE RATED VAPORSOH E D <br /> VER T SCHEDULED <br /> GYPSUM BOARD O/ TUBE WEATHER=RESISTIVE ACOUSTICAL SEALA T O <br /> O STEEL COLUMN BARRIER <br /> 2X BLOCKING o o <br /> AT 24" O.G. <br /> PLYWOOD <br /> pj TUBE STEEL COLUMN OR SHEATHING - PER 5 <br /> Z WIDE FLANGE - SEE STRUCTURAL <br /> Q) Q STRUCTURAL PLANS \J <br /> CL D <br /> Lu <br /> Lu <br /> O r Iq <br /> JLRATED GEILING z <br /> Q 2X STUDS I6" tK 2X RIMASSEMJLY <br /> OISTS - SEE < <br /> O.G. PER PLAN O II I/2" 3 <br /> WALLBOARD APPLIED AROUND TUBE H <br /> BASE LAYER 1/2" FIRE RATED GYPSUM STRUCTURAL <br /> 6 I/2" 5/8" FIRE RATED GYPSUM <br /> STEEL COLUMN. SECOND LAYER EITHER O w AO BOA-RD Z <br /> SEE PLAN NO.24 MSG GALVANIZED STEEL COLUMN <br /> COVER CONSISTING OF TWO L-SHAPED <br /> DINING AREA <br /> SECTIONS WITH SNAP-LOGK SHEET STEEL 2 I/2" <br /> CL <br /> JOINTS OR NO.22 MSG GALVANIZED <br /> AIR FINISH FLOOR 8 BASE <br /> O STEEL COLUMN GOVER5 CONSISTING OF GAP AS SCHEDULED <br /> TWO L-SHAPED 5EGTION5 WITH LAP <br /> JOINTS FASTENED WITH NO. 8 x I/2" MINERAL FIBER ACOUSTICAL SEALANT z <br /> SHEET METAL SCREWS AT 12" O.G. - INSULATION - FILL O <br /> z_ < <br /> FACE LAYER 1/2" TYPE S DRYWALL ALL VOIDS N Z J <br /> p� SCREWS 8" O.G. SPACED I" FROM 0WEEP SCREED (TYP.) ANCHOR BOLT <br /> VERTICAL EDGES. METAL CORNER BEAD <br /> APPLIED TO ALL CORNERS WITH I" TYPE 24 GA. GALVINIZED FASTENING PER <br /> S DRYWALL SCREWS 12" O.G. IN EACH FLASHING. PAINT TO STRUCTURAL <br /> +, FLANGE. MATCH STUCCO DRAWINGSC7 z <br /> REVISIONS: <br /> O <br /> UL NG505-0-6), lINK263q, ZI PLANNING 10/05/2018 <br /> 5 Z -1 VERIFY FINISHES ARE FLUSH BETWEEN FIRST AND UPPER FLOORS <br /> O 12-23-15; m <br /> O UL NG505, 11N<I518; p FIREYRATING: I HR DESIGN: E5R-IIg4 4.4.5.2 A HILTON 10/18/2018 <br /> Q UL DESIGN X526 X 21 <br /> w S.T.G.YRATING: 55+ TESTING NO. : RAL TL -71-138 HILTON 02/0-7/201q <br /> 6 GA. FILE NO. GM 1451 <br /> 75 <br /> 4 HOUR IR RTD COLUMN27 EXTERIOR DOUBLE DILL RR <br /> 4 3 3 9 3 5 1 <br /> SCALE: 3" = 1'-0" SCALE: I" = 1'-0" <br /> TJI BLOGKING (DRAFTSTOP) <br /> +, UNDERSIDE OF JOIST OR <br /> UL DESIGN NO. X606 TRUSS <br /> RATING - I HR <br /> s <br /> v <br /> -RED PROJECT # 18050 <br /> w <br /> 2 HILTON # 18-428ND <br /> IY <br /> o 1 PLANNING # SPR-18-102 <br /> PERMIT # - <br /> RATED GEILING ASSEMBLY <br /> O DOUBLE 2x TOP PLATES APN # Iq6-2-70-23 <br /> 5/8" FIRE RATED GYPSUM <br /> BOA-RD (PROVIDE DATE: O .06.IG <br /> DENSHIELD FIREGUAYRD TILE <br /> BACKER AT NET AREAS) DRAWN: H.GOLLINS <br /> PER PLAN <br /> CHECKED: J.MILLER <br /> 1. MASTIC GOATINC750 - THE USE OF THIS GOATINGREQUIRES TYPICAL LOCATION SOUND BATT INSULATION <br /> PROPER VENTILATION DURING APPLICATION AND DRYING TO (UNFAGED) <br /> O <br /> MINIMIZE THE POSSIBILITY OF AN ACCUMULATION OF • GENERAL AREAS <br /> v FLAMMABLE VAPORS. SUCH AN ACCUMULATION MAY BE <br /> p� INDICATED BY STRONG SOLVENT ODORS. APPLIED IN TWO 2x WOOD STUDS 24" O.G. SHEET TITLE: <br /> PROVIDE FIRE BLOGKING <br /> GOATS TO I/4" NET FILM THICKNESS. BECAUSE OF SOLVENT SEE FLOOR PLAN <br /> AT 10'-0" INTERVALS VARIES <br /> EVAPORATION, THE NET FILM THIGKNESS MAY BEYREDUGED A PER G.B.G SECTION -118 2x CONTINUOUS BOTTOM 2 HOUR FIRE WALL <br /> MAX OF 20 PERCENT AFTER THE GOATING HAS CURED A MIN <br /> OF 5 DAYS. STEEL SURFACES TO BE PRIMED AND "5CYRATGH" PLATE (TREATED @ FIRST ASSEMBLY DETAILS <br /> COATED WITH A MASTIC GOATING A5REQUIRED PER FLOOR) –REFER TO <br /> APPLICATION INSTRUCTIONS STRUCTURAL <br /> i„ FINISH FLOOR d BASE AS <br /> ALBI MFG, DIV OF STANGHEM INC - TYPE &qO OR A6800 4 NOM. ACOUSTICAL <br /> O INTUMESGENT MASTIC GOATIN05 FOR INTERIOR GENERAL SEALANT EACH SIDE SCHEDULED <br /> PURPOSE USE. <br /> 2. STEEL COLUMN - MIN SIZE OF COLUMN, WIOX4q, WITH <br /> OUTSIDE DIMENSION OF 10 X 10 IN., A FLANGE THIGKNESS OF 3 2" x 4" (51mm BY 102mm) MINIMUM WOOD 5TUD524"(610mm) O.G.WITH 5/8" (15.gmm) FIRE <br /> q/I6 IN., A WEB THIGKNESS OF 5/16 IN., ANDA p -RATED GYPSUM WALLBOARD APPLIED VERTICALLY OR HORIZONTALLY NAILED WITH bd <br /> 2 CROSS-SECTIONAL AREA OF 14.4 SQ. IN. N COOLER OWALLBOARD NAILS AT 7" (I i8mm)O.G.WITH END JOINTS ON NAILING MEMBERS. <br /> � STAGGEJR OINTS EACH SIDE. <br /> '"BEARING THE UL GLA55IF16ATION MARK Q SHEET NO.: <br /> 3 <br /> •• ALL BEAMS, COLUMNS TRUSSES ETC THAT SUPPORT MORE J <br /> 7� THAN THO FLOORS OR ONE FLOOR m FIRE'RATING: N/A DESIGN: - <br /> INDIVIDUALLY PROTECTED ON ALL SIDES ROOF SHALL BE <br /> 28 <br /> s — S.T•C.'RATING: - TESTING NO. : N/A <br /> (OR APPROVED EQUAL) A01 2 <br /> 48 44 40 36 32 1 HR FIRE RATED GOATI NG 28 PARTITION (INTERIOR DOUBLE HALL) <br /> SCALE: 1 1/2" = 1'-0" SCALE: I" = 1'-0" <br />