My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
161
>
1600 - Food Program
>
PR0546570
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2021 11:08:05 AM
Creation date
3/16/2021 3:01:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546570
PE
1623
FACILITY_ID
FA0026416
FACILITY_NAME
TRU BY HILTON LATHROP
STREET_NUMBER
161
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
161 E LOUISE AVE
P_LOCATION
07
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CV <br /> U) <br /> GENERAL NOTES: GUESTROOM KEYNOTES: I--- <br /> 1. REFER TO TRU BY HILTON PROCUREMENT 6UIDE FOR I. DIMENSIONS A-RE TO FACE OF STUDS - TYPICAL . U <br /> FURNITURE d BUILT-IN GASE&OODS - A LIST OF 2. PROVIDE MANEUVERING GLEARANGE AT ALL DOORS AS , LU <br /> APPROVED PROCUREMENT AGENTS IS PROVIDED. -REQUIRED BY GBG IIB-4042.4 32" MIN CLEAR WIDTH <br /> 2. REFER TO TRU BY HILTON FFdE PACKAGE FOR <br /> FURNITURE, FIXTURES d FINISH SPECS. 'REGUHRED AT AGGESSIBLE DOORS - 18" STRIKE SIDE <br /> 3. SMOKE DETECTORS, SPRINKLERS d OTHER EMERGENGY -REQUIRED AT INTERIOR DOORS - PROVIDE 12" ON THE <br /> DEVICES TO BE LOCATED PER LOCAL CODE. PUSH SIDE OF A DOOR EQUIPPED WITH A GL05ER AND A <br /> iv 4. PROVIDE EMERGENCY LIGHTING PER LOCAL CODE. U <br /> 5. WALL REGEPTAGLES/DATA PORTS TO BE MOUNTED 0 LATCH - DOOR OPENING FORGE SHALL NOT EXGEED 5LB5 �y <br /> 12" A.F.F. - TYP, U.N.O. - FIRE DOORS OPENING FORGE SHALL NOT EXCEED 15LB5 Q <br /> 6. REFER TO TRU BY HILTON BRAND 5TANDARD5 FOR 3. PROVIDE LIMIT DEVICES ON GUE5TROOM WINDOWS TO <br /> ADDITIONAL &UE5TROOM AND GUEST BATH <br /> -REQUIREMENTS. MAINTAIN 4" MAXIMUM OPENING <br /> 1. ALL CONTROLS FOR USE BY GUESTS MUST BE MOUNTED 4. HARDWIRED PTAG UNIT BRED INC ARCHITECTS <br /> J121'7 J STREET,MODESTO,GA 85354 <br /> BETWEEN 15" A.F.F. d 48" A.F.F. 5. EDGE OF PTAG ABOVE LUXURY VINYL TILE FLOORING. 20a.522.8gOO <br /> z 8. REFER TO SHEETS A200 d A201 FOR LOCATIONS OF <br /> G.F. GUE5TROOM5. 6. WALL MOUNTED TV- PROVIDE SOLID BLOCKING PER <br /> q. REFER TO SHEET A002 FOR ACCESSIBILITY MANUFACTURERS-REQUIREMENTS- VERIFY HEIGHT WITH <br /> REQUREMENT5 AND DETAILS. SEAL: <br /> O1„�NE <br /> 10. AT ADJAGENTYROOMS, ELECTRICAL OUTLET LOGATION5, 1. LOCATE WALL MOUNTED DOOR STOP WHEN DOOR OPENS. <br /> INGLUDINO TV d TELEPHONE OUTLETS, MUST BE OFFSET <br /> M <br /> FOR INSTALLATION. THE LOCATIONS SHALL BE OFFSET 5. IRON AND FRONING BOARD STORAGE ACCESSORY TO BE SED ARCy/ <br /> vTO AVOID CONFLICTS WITH FURNITURE. THIS SHALL NOT LOCATED AS SHOWN. �lL� OE BUR/r T�, <br /> AFFECT LIGHT FIXTURE OR FURNITURE LOCATIONS q, ROLLER SHADE TREATMENT MOUNTED TO FACE OF <br /> UNLESS OTHERWISE DIRECTED. BACK TO BACK OUTLETS pP <br /> ARE NOT PERMITTED. SEE DETAIL Iq/AD5 DIMENSIONS WINDOW WALL - SHEER ROLLER SHADE INSTALLED AT <br /> z SHOWN FOR THE ELEGTRIGAL OUTLET PLAGEMENT ROOM SIDE. 3 <br /> 14 SHOULD BE USED AS A GUIDE AND A-RE MEANT TO 10. BLACKOUT ROLLER SHADE AND BLACKOUT SIDE/SILL <br /> GEILING LEVEL GEILING LEVEL INDICATE IDEAL PLAGEMENT ONLY, EXACT PLAGEMENT REN. <br /> TO BE DETERMINED ON A GA5E BY CASE BASIS. THE CHANNELS INSTALLED AT WINDOW SIDE FLUSH AGAINST j 03-31-21 �P <br /> !s <br /> ° INTENT IS TO KEEP THE OUTLETS BEHIND THE DESK/TV WINDOW MULLIONS. O� <br /> p SPAOI PT03 SPA02 ° S , . FOFC <br /> MILLWORKAND NIGHTSTANDS CONGEALED <br /> w 0 � SPAOI 14 SPAOI II. LIGHTS IN THIS AREA MUST BE DAMP LOGATION�RATED Al <br /> II. LIGHT SWITCH AND G.F.I. OUTLET CAN BE MOUNTED IN �.�/SHATTER PROOF LENSES. <br /> Q COMMON 4X4 BOX WITH COVER PLATE. COORDINATE <br /> N PT31 CLEARANCE WITH MIRROR. 12. PROVIDE DEN-SHIELD AT AREAS WHERE MOISTURE IS <br /> 12. INSTALLATION HEIGHT OF ALL SWITCHES, OUTLETS, ETC., PRESENT WITH GEILING JOISTS AT 12" OG - TYPIGAL <br /> ARE TO MEET A.D.A-REQUIREMENTS AND/OR LOCAL <br /> 2 1 CODES. 13. FLOOR FINISH NOT PROVIDED UNDER PRE-MANUFACTURED <br /> IS 13, SEE SHEET A'700 FOR-ROOM FINISH 5GHEDULE. SHOWER PAN - COORDINATE WITH SPEGIFIGATION. <br /> X SPAOI 14, SUBMIT SHOP DRAWINGS FOR-REVIEW AND APPROVAL 14, PROVIDE BAGKIN6 FOR GLOTHE5 HANGING BAR AT WALL CONSULTANT: <br /> O 88 �I 6 T PRIOR TO FABRICATION OF ANY MILLWORK. AND CEILING. <br /> 15. PROVIDE SOLID WOOD BLOCKING FOR SECURE <br /> USB 1515.15. LOCATION OF EVACUATION MAP AND/OR ADDITIONAL <br /> ATTACHMENTS OF ALL FIXTURES, ART, GRAB BARS, <br /> z WINDOW COVE-RINC75 AND ALL OTHER WALL-MOUNTED -ROOM SIGNAGE AS-REQUIRED BY LOCAL JURISDICTION. <br /> ul 0 16 Q ITEMS. <br /> 16. REFER TO TRU BY HILTON PROCUREMENT GUIDE FOR <br /> Il 16. PROVIDE THREE ROBE HOOK AT &UE5TROOM5 AND <br /> _O O INTERIOR SIGNAGE VENDORS. <br /> V <br /> N m _ O O FOURRROBE HOOKS IN ALL AGGESSIBLE GUEST <br /> BATHROOMS. TWO W <br /> O AT STANDARD HEIGHT AND TO AT Il, ELEGTRIGAL DEVIGE5-REQUIRED TO BE INSTALLED WITHIN <br /> rn L - ACCESSIBLE HEIGHT. CA5E&000 CUTOUT AS INDICATED. <br /> Il. FINISH LAYER AT ALL WALLS IN BATHROOMS TO BE <br /> T L - -1DEN-SHIELD. 18. DOORBELL ON/OFF SWITCH (G.F,-ROOMS ONLY) -SIGNAGE <br /> tL FINISH FLOOR LEVEL FINISH FLOOR LEVEL 0. CEILINGS IN BATHROOMS SHALL BE DEN-SHIELD. ASfREQUtRED. <br /> Iq. ALL TUB/SHOWER ENGL05URE5 TO BE FRAMED WITH A Iq. STARTING POINT OF TILE - BEGIN WITH THE FULL TILE. <br /> BOIBOI Il BOI MINIMUM-ROUGH OPENING GLEARANGE OF 5'-1 1/2" WIDE 20.DESK MUST PROVIDE MIN. 30" WIDE GLEA-R FLOOR SPACE <br /> E301BOI BOI AND MINIMUM FRAMED DEPTH OF 3'-0 1/2" TO ALLOW <br /> FOR DEPTH OF FIXTURE AND PROPER TERMINATION OF AND A MIN.21" HIGH KNEE CLEARANCE. <br /> SURROUND. 21. ALL OUTSIDE CORNERS SHALL HAVE FULL HEIGHT CORNER <br /> 20.ALL DECORATIVE MATERIALS AREREQUIRED TO BE GUARDS <br /> MAINTAINED IN FLAME-RETARDANT CONDITIONS. NO <br /> FINISHES UNDER SHOWER PAN / TUB. 22. PROVIDE BLOGKIN& FOR HEAD BOARD - COORDINATE <br /> ROOMl- YTI OI `l ROOI IL Y 1-"�TI OI `4 21. UNITS DESIGNATED AS HAVING COMMUNICATIONS WITH FURNITURE LAYOUT d SPECIFICATIONS <br /> FEATURES IN AG60ROANGE WITH G.B.G. II13-806.3 A-RE <br /> TO BE EQUIPPED WITH VISUAL WARNING DEVICES IN <br /> ACCORDANCE WITH G.B.G. II15-102 FOR CARBON <br /> MONOXIDE, FIRE d SMOKE ALARMS. <br /> FURNISHING LEGEND: <br /> GEILING LEVEL CEILING LEVEL CR-102 TASK CHAIR AT &UE51ROOM <br /> &R-200 LUGGAGE BENCH AT LANDING ZONE <br /> q ° &R-201 AGGENT NIGHTSTAND AT KIN& &UESTYROOM <br /> ° PT03 q 10 IF -1 F C-R-20- a NG PLATFORM BED BLATFORM BED A51E by HILTON" <br /> 10 <br /> SPAOI 0 &R-213 LANDING ZONE FIXTURE" <br /> &R-214 LANDING ZONE FIXTURE AT ADA GUEST-ROOMS** <br /> Il 0 0 0 &R-215 KING HEADBOARD" <br /> &R-216 QUEEN HEADBOARD" <br /> 6-2" 3'-2" &R-211 KING NIGHTSTAND <br /> 6 SPAOI &R-218 DOUBLE QUEEN NIGHTSTAND Z <br /> N�lp &R-21q TV WALL UNIT WITH INTEGRATED POWER'"' <br /> vv v v6 Il &R-220 LAMINATE WALL PANELS AT TV WALL <br /> 0 0 0 &R-221 STORAGE BENCH AT KING AND CONNEGTIN& <br /> O ®® &UE5TROOM5 LL <br /> &R-222 ELONGATED STORAGE BENCH AT DOUBLE QUEEN J <br /> GUE5TROOM5 Q <br /> X &R-223 MOBILE DESK <br /> Q &R-304 BEDSIDE LAMP AT KING GUESTROOM <br /> Z &R-305 HEADBOARD SCONCE AT OUESTROOM <br /> &R-30(o FLOOR LAMP AT &UE5TROOM <br /> ® m C-5R-301 NALL SCONCE AT FULL LENGTH MIRROR <br /> &R-308 WALL 5GONGE AT DESK <br /> cN <br /> was &R-30q BEDSIDE LAMP AT DOUBLE QUEEN &UE5TROOM <br /> &R-310 AGGESSIBLE HEADBOARD SCONCE AT <br /> FINISH FLOOR LEVEL FINISH FLOOR LEVEL <br /> GUESTROOM <br /> % O'-O" 4 O'-O" <br /> &R-311 AGGESSIBLE WALL SCONCE AT DESK <br /> 0 <br /> CR-402 DUAL ROLLER SHADE WITH INSIDE MOUNT <br /> BOI BOI BOI BLACKOUT AND OUTSIDE MOUNT PRINT o <br /> CR-403 HARDWIRED MOTORIZED DUAL-ROLLER SHADE <br /> AT&R-601 FULL LENT ACCESSIBLE <br /> AT LANDING ZONE • <br /> v <br /> N CR-801 WASTE BASKET AT GUESTROOM <br /> s ROOMI \ / TI O}� I ROO1��( L \ /TCTIOI�I "REQUIRES BLOCKING - REFER TO MILLWORK a <br /> I " I L l( Irl I " I �( IVn <br /> BLOCKING DIAGRAM'""" <br /> < <br /> o <br /> o PLAN SYMBOL LEGEND: <br /> LLJ <br /> ry <br /> O O SHEET O <br /> IINDON TTA& - SEE WINDOW 5GHEDULE ON <br /> O <br /> DOOR TAG - SEE DOOR SCHEDULE ON SHEET o <br /> E <br /> 1033A) A&OO <br /> WALL TYPE TAG - SEE WALL ASSEMBLY <br /> SHEETS AOII - A015 (� <br /> O <br /> X <br /> o ELEVATION TAG <br /> AXXX Z <br /> 3 <br /> N <br /> KEYNOTE TAG Q <br /> O IINDON IENTATION <br /> O BE DETERMINED BY <br /> X EXTERIOR ELEVATION O XXX FINISH TAG <br /> Z <br /> O <br /> INFORMATION Q <br /> NOTE: ELECTRICAL ITEMS SHOWN FOR 15'-2" 10 e ~ <br /> XX-XXX FURNITURE/EQUIPMENT TAG <br /> v -REFERENGE ONLY- SEE ELEGTRIGAL �- <br /> oDRAWIN65 2 3/4 6'-6 1/4" l'-2" I'-5 3/4" V <br /> 2 3/4" <br /> OI GUESTROOM GEILING LEGEND: <br /> O Q <br /> p) II ■ II ■ II I II I - .I � II ■ II ■ II ■ II ■ II II � GEILIN& HEIGHT <br /> &R- 03 Lz3R-OT _8� -403 - - - - - - <br /> I 8'-O"C GEILING FINISH <br /> O <br /> CR-311 'I� CR-311 I I ' q I 5 I EXT, A. PRIMED 8 PAINTED GYPSUM BOARD 'REVISIONS: <br /> z zVFO6 FLOOR <br /> q B. PRIMED 8 PAINTED GYPSUM BOARD - MOISTURE RESISTANT I PLANNING 10/05/2018 <br /> 9�N_ CR-30(� 'LL R-306 � I I I ' I HILTON 10/18/2018 <br /> &R-201 &R-201 BASE <br /> CR-305 &R-102 w w CR-102 CR-305 A3 HILTON 02/0-7/201q <br /> 3 v v <br /> 6 <br /> T) -215 / O O O CR \ --- &R-21 <br /> sI ~ ~ /R- 1 ' PTOI m A m <br /> 5-OIS / C \ 1 05-01,6 1 <br /> 05-OIq 21q\ �CR 21 OS-OIq - I 1 - <br /> &R-201 QS-o11 II o5-OI �-201 ' ' EXT. A402 B GUESTROOM GEILING LEGEND: <br /> N z z /1 0 �REGE55ED DOWNLI&HT <br /> � <br /> cp <br /> 13 �fREGE55ED DOWNLIGHT - UL NET LABELED <br /> c 4 CR-30 Q CR-21l CR-211 Qom° �� FZI EXHAUST FAN RED PROJECT # 18050� <br /> m 05-012 <br /> � m � � � - I - 14 OS-012 � I m 2'-0 3/4" ® I HILTON # 18-428ND <br /> PLANNING # SPR-18-102 <br /> O <br /> s -CiR- - 00 z NALL TYPES PERMIT # - <br /> --� - II PT2q 12 ' AGGESSIBLE TUB 3 O <br /> Q - <br /> ° OS-016 OS-016 n O v 0) 1 HOUR FIRE PARTITION APN # Iq6-2�0-23 <br /> O ° J �° ° 7'-6"B 405 6 ° l °J I w <br /> OS-010 OS-010 N � Z I HOUR FIRE BARRIER <br /> L-15 HOLD L-11 D I O p DATE: 03.06.Iq <br /> -R <br /> r - I - II II - OLL-IN SHOWER <br /> T5 O5 - - IRDRAWN: H.GOLLINS <br /> / I / II II � 2 HOUR FE BARRIER <br /> � C \O -014 F CL Cr 05-01- l'-6"G I 6 I TYPICAL INTERIOR WALL GHEGKED: J.MILLER <br /> OS-OI5 <br /> s I 11 12 PT02 � i � I HOUR FIRE PRATED EXT.2X6 WALL <br /> SEE SHEET A013 <br /> FLOOR o p SHEET TITLE: <br /> - - <br /> - � PTOI � B02 BASE <br /> r SEE SHEETS AOII d A012 FOR WALL ACCESSIBLE KING SUITE <br /> I FOR <br /> PENETRATION DETAILS, <br /> AND A013 FOR ENLARGED PLANS & <br /> 3 � WALL TYPE PLANS. ELEVATIONS <br /> s GENTS 2 <br /> ON 10 <br /> TOILET ol q 1/2" <br /> O <br /> p) q'-l" 6-0 1/2" <br /> L L L <br /> 2ND-4TH LEVEL <br /> ol 15'-1 1/2" <br /> SHEET NO.: <br /> O �n��1��RA PIAN 1_��T BURN I TURA PLAN R I G f�T R��l_�GT�D G� I l- I FICC Pl_A� ARGf�I 7�GTURAI_ PI-AI�" SCALE: I/4" = I'-O" <br /> s MAIN LEVEL A402 <br /> KEY PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.