My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
161
>
1600 - Food Program
>
PR0546570
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2021 11:08:05 AM
Creation date
3/16/2021 3:01:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546570
PE
1623
FACILITY_ID
FA0026416
FACILITY_NAME
TRU BY HILTON LATHROP
STREET_NUMBER
161
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
161 E LOUISE AVE
P_LOCATION
07
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N , ^ <br /> NINDON GENERAL NOTES: v~J <br /> I. -REFER TO SPECIFICATIONS FOR ADDITIONAL GLAZING • <br /> REQUIREMENTS. WI— <br /> 2. GLAZING IN THE FOLLOWING LOCATIONS SHOULD BE OF — <br /> SAFETY GLAZING MATERIAL IN ACCORDANCE W/ LOCAL <br /> CODE: <br /> N v' ` <br /> A.FIXED d SLIDING PANELS OF SLIDING DOOR ASSEMBLES 8 n/ <br /> PANELS IN 5NINC71NO DOORS LL <br /> o B.WINDOWS WITHIN 24" OF DOORS IN ANY POSITION, WHERE <br /> THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS <br /> THAN 60 INCHES ABOVE THE WALKING SURFACE. RED INC A-RGHITEGTS <br /> J 1211 J STREET,MODESTO,GA 95354 <br /> z G.INDIVIDUAL FIXED OR STOP (WALL OR CLOSER MOUNTED) 209.522.8900 <br /> PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED ABOVE, <br /> THAT MEET ALL OF THE FOLLOWING CONDITIONS: <br /> SEAL: <br /> i EXPOSED AREA OF AN INDIVIDUAL PANE IS GREATER <br /> THAN q 50.FT. <br /> O <br /> Q <br /> 12'-O" <br /> Qq, 6„ ii) EXPOSED BOTTOM EDGE IS LESS THAN IS" ABOVE THE USED ARCy/� <br /> ol EQ. EQ. 22'-6" \�� BUR�F�FCA <br /> EQ. EQ. iii) EXPOSED TOP EDGE IS GREATER THAN 36" ABOVE THE pP <br /> 3'-O" 6' O" 3'-O" EQ, EQ. EQ, EQ. it EQ. FLOOR <br /> z <br /> E NITHIN 36" <br /> Il Il 3 Il -7'-2" <br /> iv) ONE OR HORIZONTARE V4ALKINC7 LLY OF THE SURFACES <br /> LANE OF THE E GLAZING. 3 <br /> � AD5 LLI � AD5 AD5 I AD5 I tP �P <br /> WINDO ORIENATATION TO I I I I I 13 TF REN. <br /> Q 3. ALL 6UE5T-ROOM WINDOWS ARE SLIDING PER GBG _X 03-31-21 <br /> w <br /> BE DETERMINED AD5 SECTION 1030 OFCA <br /> Y BY EXTERIOR T T O 4. ALL WINDOW SILLS SHALL BE QUARTZ TO MATCH <br /> a ELEVATIONS N <br /> VANITY /KITCHEN. <br /> w <br /> 5. MANUFACTURER 15-REGUIREP TO VERIFY ALL FIELD <br /> DIMENSIONS PRIOR TO FABRICATION d INSULATION OF <br /> I S 18 �0 <br /> `n IS N WINDOWS <br /> o AD5 AD5 m p AD5 p 6. 6UESTROOM WINDOW FRAMES SHALL BE 'KAWNEER' 5450 <br /> CONSULTANT: <br /> T DOOR TYPE A OR APPROVED EQUAL. <br /> T T T T T T T T <br /> O T T 1. WINDOWS SHALL MEET OR EXCEED LOCAL ENERGY CODES. <br /> PROVIDE 0.32 U VALUE AND 0.25 SHGG GLAZING AS <br /> 'REQUIRED BY TITLE 24 ENEROYREPORT <br /> w m m m AD5 GG <br /> 8. TYPE 'E' PTAG RILLS ARE TO BE INTEGRAL TO THE <br /> z T T T T T T T T T N WINDOW, NO SUBSTITUTIONS WILL BE ALLOWED. <br /> w <br /> z 20 20 l 20 <br /> G. EXTERIOR WINDOWS SHALL BE TESTED AND LABELED AS <br /> CONFORMING TO AAMA/WDMA/G5A101/1.5.2/A440. <br /> LL AD5 AD5 AD5 AD5 <br /> TYPE A TYPE B TYPE G TYPE D IO.WINDOW FLASHING TO BE INSTALLED PER DETAIL 23/AD5 <br /> EXTERIOR STOREFRONT EXTERIOR STOREFRONT EXTERIOR STOREFRONT <br /> DUAL GLAZING DUAL GLAZING DUAL GLAZING EXTERIOR OPERABLE WINDOW 11. LOUVERS FOR THRU-WALL HVAC UNITS IN 6UE5TROOM5 <br /> VESTIBULE ENTRY DUAL GLAZING MUST BE FURNISHED BY THE WINDOW MANUFACTURER AND <br /> GUESTROOM / FITNESS/ GEN. MUST BE ALUMINUM, A-RGHITEGTURAL-STYLE WITH A FINISH <br /> MANAGER OFFICE TO MATCH THE WINDOW SECTIONS. LOUVERS MUST MEET <br /> THE FREE AIR-REQUIREMENTS OF THE THRU-WALL UNIT <br /> SELECTED. <br /> 12.6ENERAL CONTRACTOR 15-REGUIRED TO VERIFY ALL <br /> DOOR, WINDOW 8 PTAG INSTALLATIONS A-RE PROTECTED <br /> FROM OTHER TRADES DURING CONSTRUCTION - DAMAGED <br /> UNITS TO BE-REPAIRED OR-REPLACED AT THE <br /> CONTRACTORS EXPENSE TO THE 5AT15FAGTION OF THE <br /> OWNER. <br /> 13.OPERABLE WINDOWS ARE TO BE SCREENED. <br /> 24 I 24 <br /> AD5 AD5 i AD5 MINIMUM ENERCYZAGOUST I G <br /> 13 I REQUIREMENTS FOR CLAZ I NC <br /> AD5 <br /> O <br /> T T N "SEE TITLE 24" FOR REQUIREMENTS by HILTON- <br /> 5 <br /> AD5 PTAG UNITS - MINIMUM ACOUSTICAL REQUIREMENTS <br /> Q <br /> 0 6 T T 6 T 6 ALL PTAG UNITS RE-REQUIRED TO MEET OR EXCEED A Z <br /> z <br /> T T DOOR TYPED r A-RE <br /> OUTDOOR-INDOOR TRANSMISSION GLASS (OITG) = 23 <br /> IG IG MINIMUM SOUND TRANSMISSION COEFFICIENT OF (STG) = LL <br /> "SEE SOUND STUDY FOR"YZEQUhREMENTS. J <br /> NAD5 m AD5 m MINIMUM-R000H OPENING SEE MANUFACTURER SPECIFICATIONS. v <br /> 15 NI- <br /> AD5 6 <br /> TYPE E AD5 TYPE F TYPE G TYPE H <br /> EXTERIOR OPERABLE WINDOW EXTERIOR EXTERIOR EXTERIOR TYPICAL CUESTROOM NINDON NOTES: <br /> DUAL GLAZING DUAL GLAZING DUAL GLAZING DUAL GLAZING <br /> 6UE5TROOM WITH BUILT-IN PTAG ELEVATOR LOBBY GAME-ROOM 6AME-ROOM <br /> I. DUAL PANE ALUMINUM WINDOWS (KAWNEER 5450) OR <br /> APPROVED EQUAL. MANUFACTURERS TO SUBMIT SHOP • <br /> DRAWINGS AND SAMPLES FOR APPROVAL PRIOR TO W <br /> FABRICATION. 0 <br /> N <br /> 2. ALL OPENABLE EXTERIOR WINDOWS SHALL BE SCREENED <br /> s WITH NOT LESS THAN SIXTEEN (I(b) MESH PER SQUARE INCH <br /> SCREENING <br /> 3. OPERABLE WINDOWS, WHEN-REQUIRED, MUST HAVE A W <br /> GHILDPROOF LOGKING DEVICE APPROVED BY HILTON AND <br /> A-RE NOT ALLOWED TO OPEN MORE THAN 47102 MM <br /> 4. CONTRACTOR TO'REVIEW STG, U-VALUE AND SHGG <br /> 22'-2" EQ. EQ. <br /> REQUIREMENTS PRIOR TO PRICING AND ORDERING <br /> WINDOWS. <br /> EQ. EQ. EQ. 3' 0 6,'O 3' 0 O <br /> w 3'-4" 7r 7r 7 e <br /> 24 AD5 I I 3 6ol <br /> AD5 I 4 CLAZ I NC LEC END: coI.LI <br /> AD5 � � AD5 <br /> i i 13 i SYMBOL: GOLOR: DESCRIPTION: <br /> AD5 T GLEAR TEMPERED INSULATED 5/8" �O <br /> s O r T O CLASS <br /> T DC GLEAR DUAL-GLAZED I" THICK, <br /> s 5 � <br /> LOW 'E' GLASS <br /> FL GLEAR FIRELITE PLUS I HOUR Z <br /> AD5 18 RATED CLASS <br /> d <br /> N <br /> T T T r 6 <br /> O DOOR <br /> v TYPE B r � DOOR TYPE A <br /> r- <br /> T <br /> i z <br /> 14 <br /> m m <br /> AD5IIIcv T T � CL <br /> UPPER F.F. ILx <br /> 6 - - - 20 1 z <br /> AD5 TYPE I TYPE J TYPE K AD5 TYPE L AD5 0 Q <br /> EXTERIOR EXTERIOR EXTERIOR INTERIOR WINDOW <br /> O DUAL 6LAZIN6 DUAL GLAZING DUAL GLAZING VESTIBULE ENTRY <br /> s <br /> GAME-ROOM DINING UPPER CORRIDOR <br /> N <br /> REVISIONS: <br /> 0 <br /> C7 <br /> Z1 PLANNINO 10/05/2010 <br /> A HILTON 10/18/2018 <br /> 3 HILTON 02/0-7/201 q <br /> L <br /> s <br /> v <br /> N 21 <br /> � AD5 <br /> w <br /> Q <br /> v <br /> w ZED PROJECT # 18050 <br /> D <br /> HILTON # 18-428ND <br /> PLANNING # SPR-18-102 <br /> C) <br /> DOOR cv PERMIT # <br /> TYPE G r <br /> APN # I q6-2-70-23 <br /> 0 <br /> DATE: O .062.1 q <br /> FL/T <br /> N <br /> DRAWN: H.GOLLIN5 <br /> V I NI IN <br /> � 22 <br /> GHEGKED: J.MILLER <br /> AD5 TYPE M <br /> O INTERIOR WINDOW <br /> FITNESS <br /> o SHEET TITLE: <br /> s <br /> NOTE: <br /> n WINDOW AND STOREFRONT MANUFACTURERS TO WINDOW SCHEDULE <br /> N SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO <br /> FABRICATION - TYPICAL <br /> N GLASS IN LOCATIONS SUBJECT TO HUMAN IMPACT <br /> SHALL BE TEMPERED PER GBG 2406 <br /> O <br /> Co STOREFRONT FINISH: CLEAR ANODIZED <br /> p 1/4" CLEAR GLAZING - TYPICAL AT INTERIOR UNLESS <br /> OTHERWISE NOTED - VISTAWALL F6-1000 SERIES <br /> I" DUAL PANE INSULATED GLAZING - VISTAWALL <br /> SERIES 3000 MULTIPLANE FRONT SET - TYPICAL AT SHEET NO.: <br /> EXTERIOR UNLESS OTHERWISE NOTED <br /> O <br /> w <br /> A801 <br />
The URL can be used to link to this page
Your browser does not support the video tag.