My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2025
>
3600 - Recreational Health Program
>
PR0546587
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/13/2021 3:43:36 PM
Creation date
3/24/2021 7:33:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0546587
PE
3612
FACILITY_ID
FA0026383
FACILITY_NAME
HOMES 2 SUITES BY HILTON TRACY
STREET_NUMBER
2025
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
2025 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I Environmental Health Department <br /> S A N-6J 0 A 0 Uvii fir : C(--)L) Y Time In: 10.30 am <br /> Time Out: 11:20 am <br /> i�+Fasxt�` Greotness grows here. <br /> Swimming Pool Service Request Inspection Report <br /> Name of Facility: HOME 2 SUITES Date: 02/03/2021 <br /> Address: 2025 W GRANT LINE RD ,TRACY 95377 <br /> Requestor: KEN KELLEY, POOLS BY POOLQUIP INC Telephone: (559)217-0639 <br /> Program Element: 3601 -NEW POOL/SPA PLAN CHECK Request#: SR0080086 <br /> Inspection Type: 523-Plan Check/Report Review <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043,116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:one light in the pool is not functioning. Repair prior to opening the pool. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31158) <br /> #25 Spa Emergency Shut Off Switch <br /> OBSERVATIONS:Unable to test the emergency shut off because the jets would not come on. Repair prior to opening the <br /> pool. <br /> CALCODE DESCRIPTION:A clearly labeled emergency shut off switch for both the spa recirculation and jet/aeration systems shall be <br /> installed adjacent to the spa pool. (CBC 31388) <br /> #32 Chemical Control and Monitoring System <br /> OBSERVATIONS:The spa chemical monitoring system not functioning. The flow switch. Repair prior to opening the pool. <br /> CALCODE DESCRIPTION:Chemical feeders shall be constructed with an adjustable output rate device controlled by an approved <br /> automatic chemical monitoring and control system that regulates at minimum pH and disinfectant. Chemical feeders shall be constructed <br /> and installed to prevent uncontrolled discharge or siphoning of chemicals and fumes directly into the pool,recirculation system,pool area, <br /> or ancillary facilities. (CBC 31338) <br /> #36 Pressure and Vacuum Gauges <br /> OBSERVATIONS:Vacuum gauges not install on the pumps. Install prior to opening the pool. <br /> CALCODE DESCRIPTION:Pressure and vacuum gauges shall be provided for each pump system. (CBC 31256) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> The door from the building opens into the pool without a key. The door must be locked from the inside and only open with a <br /> key from staff. See the requirements below. <br /> 31198.2 Gates. <br /> Gates and doors shall open outwardly away from the pool except where otherwise prohibited by law. <br /> 31198.1 Enclosure. <br /> SR0080086 SC523 02/03/2021 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.