Laserfiche WebLink
urrY I Environmental Health Department <br /> 41 t: SAN-6-JOAQU <br /> vii ��r�: � C(--)LJ Y Time In: 9.55 am <br /> Time Out: 10:30 am <br /> i�+Fasxt�` Greotness grows here. <br /> Swimming Pool Service Request Inspection Report <br /> Name of Facility: STONBRIER APARTMENTS Date: 02/02/2021 <br /> Address: 4770 WEST LN , STOCKTON 95210 <br /> Requestor: GREG WHEATLEY, SPRING CREEK POOL&SPA, INC. Telephone: (209)599-5502 <br /> Program Element: 3601 -NEW POOL/SPA PLAN CHECK Request#: SR0081625 <br /> Inspection Type: 523-Plan Check/Report Review <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043,116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #3 Safety Signs <br /> OBSERVATIONS:Provide the address on the sign, <br /> provide the capacity of the pool. 20 square feet per bather of surface area. <br /> keep gate close signs on entrance doors. <br /> Diarrhea signs at entrances. <br /> Provide these signs prior to opening the pool. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31206) <br /> #4 Safety Equipment <br /> OBSERVATIONS:Provide a 12 feet pole for the body hook. Correct prior to opening the pool. <br /> CALCODE DESCRIPTION:Safety equipment shall be provided, maintained, readily visible, and available for use.Pools shall have at <br /> minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br /> rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br /> (CCR 65540) <br /> #32 Chemical Control and Monitoring System <br /> OBSERVATIONS: Install the chemical control and monitoring system electrically interlocked with the the filtration pump. <br /> Correct prior to opening the pool <br /> CALCODE DESCRIPTION:Chemical feeders shall be constructed with an adjustable output rate device controlled by an approved <br /> automatic chemical monitoring and control system that regulates at minimum pH and disinfectant. Chemical feeders shall be constructed <br /> and installed to prevent uncontrolled discharge or siphoning of chemicals and fumes directly into the pool,recirculation system,pool area, <br /> or ancillary facilities. (CBC 31336) <br /> #36 Pressure and Vacuum Gauges <br /> OBSERVATIONS:Make sure to mark the pressure when the filter is clean ont he influent gauge, and install a vacuum <br /> gauge. Correct prior to opening the pool. <br /> CALCODE DESCRIPTION:Pressure and vacuum gauges shall be provided for each pump system. (CBC 31256) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> SR0081625 SC523 02/02/2021 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool Service Request Inspection Report <br />