My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_1993 - 1996
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
31130
>
4400 - Solid Waste Program
>
PR0440003
>
CORRESPONDENCE_1993 - 1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2021 2:23:18 PM
Creation date
3/24/2021 11:16:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
1993 - 1996
RECORD_ID
PR0440003
PE
4434
FACILITY_ID
FA0003698
FACILITY_NAME
CORRAL HOLLOW LANDFILL
STREET_NUMBER
31130
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25303010
CURRENT_STATUS
01
SITE_LOCATION
31130 CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
233
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STANDARD PROVISIONS AND REPORTING REQUIREMENTS September 1993 <br />FOR WASTE DISCHARGE REQUIREMENTS <br />FOR DISCHARGES REGULATED BY CHAPTER 15 AND/OR PART 258 -12- <br />a. <br />12_a. For the Volatile Organics Monitoring Parameter For Water Samples [VOCwaterp <br />For any given Monitoring Point, the VOC Water Monitoring Parameter is a composite <br />parameter addressing all detectable VOCs. <br />The Discharger shall conclude that a release is tentatively indicated for the VOCwater <br />Monitoring Parameter if the data for any Monitoring Point contain either <br />i. two or more qualifying VOCs that equal or exceed their respective MDLs, or <br />ii. one qualifying VOC that equals or exceeds its PQL. <br />b. For the Volatile Organics Monitoring Parameter For Soil Pore Gas Samples [VOCSpg ]: <br />The VOLS.. Monitoring Parameter is a composite parameter for soil pore gas addressing <br />all VOCs detectable using either GC or GC/MS analysis of at least a ten liter sample of <br />soil pore gas (e.g., collected in a vacuum canister). It involves the same scope of VOCs <br />as does the VOC water Monitoring Parameter. <br />The Discharger shall conclude that a release is tentatively indicated for the VOCSp9 <br />Monitoring Parameter if the data for any Monitoring Point contain either <br />i. two or more qualifying VOCs that equal or exceed their respective MDLs, or <br />ii. one qualifying VOC that equals or exceeds its PQL. <br />C. For Constituents of Concern: <br />The Discharger shall conclude that a release is tentatively indicated if the data for any <br />Monitoring Point contain either <br />i. two or more qualifying constituents that equal or exceed their respective MDLs, or <br />ii. one qualifying constituent which exceeds its PQL. <br />�W3 <br />1. If the Discharger determines that there is significant statistical evidence of a release (i.e. the <br />initial statistical comparison or non -statistical comparison indicates, for any Constituent of <br />Concern or Monitoring Parameter, that a release is tentatively identified), the Discharger shall <br />immediately notify the Board verbally as to the Monitoring Point(s) and constituent(s) or <br />parameter(s) involved, shall provide written notification by certified mail within seven days of <br />such determination [2550.80(1)], and shall carry out a discrete retest (see below). <br />If the retest confirms the existence of a release, the Discharger shall carry out the requirements <br />of 3. below. In any case, the Discharger shall inform the Board of the outcome of the retest as <br />soon as the results are available, following up with written results submitted by certified mail <br />within seven days of completing the retest. <br />