2300 - Underground Storage Tank Program
>
PR0231438
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2021 8:16:46 AM
Creation date
3/29/2021 11:27:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231438
PE
2361
FACILITY_ID
FA0003716
FACILITY_NAME
SUPER STOP GAS & LIQUOR*
STREET_NUMBER
290
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22309101
CURRENT_STATUS
01
SITE_LOCATION
290 N MAIN ST STE C
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Secondary Containment Testing Report Form <br />6. TANK SECONDARY CONTAINMENT TEST <br />Test Method Developed by ❑ Manufacturer © Industry Standard ❑ Professional Engineer <br />Test Type ❑ Pressure © Vacuum ❑ Hydrostatic <br />Test Equipment Used: Vacuum Pump/Vacuum Gauges in Hg. <br />Tank ID <br />1 &2-91-Dsl. <br />3-87 <br />3 -Regular 87 <br />Tank Manufacturer <br />Mosier Bros. <br />Mosier Bros. <br />Ameron <br />Tank Capacity <br />12K 2 Compt. <br />12K <br />8:35 <br />Test Start Time <br />8:50 <br />8:40 <br />5 Psi <br />Initial Reading <br />-10" Hg. <br />-10" Hg. <br />9:35 <br />Test End Time <br />9:50 <br />9:40 <br />5 Psi <br />Final Reading <br />-10" Hg. <br />-10" Hg. <br />0 <br />Change in Reading <br />0 <br />0 <br />No Loss <br />Pass/Fail Criteria <br />No Loss <br />No Loss <br />® Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Tightness Test Results <br />® Pass ❑ Fail <br />I ® Pass ❑ Fail <br />I ❑ Pass ❑ Fail <br />I ❑ Pass ❑ Fail <br />17. PIPE SECONDARY CONTAINMENT TEST <br />Test Method Developed by ❑ Manufacturer ® Industry Standard ❑ Professional Engineer <br />Test Type ® Pressure ❑ Vacuum ❑ Hydrostatic <br />Test Equipment Used: Pressure Gauges in Psi/Nitrogen <br />Pipe Run ID <br />1 -Super 91 <br />2 -Diesel <br />3 -Regular 87 <br />Pipe Manufacturer <br />Ameron <br />Ameron <br />Ameron <br />Test Start Time <br />8:55 <br />8:45 <br />8:35 <br />Initial Reading <br />5 Psi <br />5 Psi <br />5 Psi <br />Test End Time <br />9:55 <br />9:45 <br />9:35 <br />Final Reading <br />5 Psi <br />5 Psi <br />5 Psi <br />Change in Reading <br />0 <br />0 <br />0 <br />Pass/Fail Criteria <br />No Loss <br />No Loss <br />No Loss <br />Tightness Test Results <br />© Pass ❑ Fail <br />© Pass ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Pipe Run ID <br />Pipe Manufacturer <br />Test Start Time <br />Initial Reading <br />Test End Time <br />Final Reading <br />Change in Reading <br />Pass/Fail Criteria <br />Tightness Test Results <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Additional copies of this page may be attached. <br />All tests marked "Fail' and any repairs made before or during the tightness test must be described in <br />the COMMENTS section. <br />Page 2of5 <br />