Laserfiche WebLink
SANsJOAQUIN <br />COUNTY <br /> <br />joeT.-2 Greatness grows here. Kasey Foley, REHS, Assistant Director <br />Environmental Health Department <br />Linda Turkatte, REHS, Director <br />PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, REHS, RDI <br />Michael Kith, REHS <br />Willy Ng, REHS <br />Muniappa Naidu, REHS <br />08/01/2019 <br />Joe Gotelli & Sons <br />9189 N Ashley Ln <br />Stockton, CA 95212 <br />RE: Well Pump Inspection <br />Weil Location: 4898 Live Oak Rd. Lodi, CA 95240 Permit #: WP0039876 Inspection Date: 08/01/2019 <br />The Environmental Health Department recently conducted a water well pump inspection at the above address <br />and found the following issues at the time of the inspection. In order to protect the ground water supply and <br />your water source from potential degradation, please take the associated corrective actions. <br />Lack of or Inadequate Concrete Platform around Wellhead. <br />(SJC Water Well Standards, Section 4.10.— Surface Seal) <br />Corrective Action: Repair existing or install a new concrete platform around the wellhead that <br />extends two feet in all directions from the well casing. <br />Lack of or Inadequate Sanitary Seal at Wellhead. <br />(SJC Ord. Code, Title 9, Section 9-1115.5. — Well Regulations) <br />Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br />openings. <br />El Lack of or Inadequate Sampling Tap. <br />(SJC Water well Standards, Section 4.13.— Sampling Tap) <br />Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br />or within three (3) feet of the well head. <br />Lack of or Inadequate Backflow Prevention. <br />(SJC Water Well Standards, Section 4.14. — Backflow Prevention) <br />Corrective Action: Install an approved protective device to prevent backflow and/or back <br />siphonage into a well. <br />Sounding Tube or Air Vent not Sealed. <br />(SJC Water Well Standards, Section 4.13.— Sounding Tube/Air Vent Pipe) <br />Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br />of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br />downward direction and covered with 16-mesh screening. <br />El Excessive Vegetation or debris around Wellhead. <br />(SJC Ord. Code, Section 9-1115.4. — Dangerous/Nuisance) <br />Corrective Action: Remove and maintain debris and vegetation away from well area. <br />If you have any questions, contact: Aaron Gooderham, Environmental Health Assistant (209) 468-3442, <br />Please call when work is complete. <br />Michael Kith, REHS <br />Program Coordinator <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjcehd.com