My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0014056
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
POCK
>
3009
>
2600 - Land Use Program
>
PA-2100031
>
SU0014056
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 9:36:37 AM
Creation date
4/7/2021 2:18:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0014056
PE
2666
FACILITY_NAME
PA-2100031
STREET_NUMBER
3009
Direction
S
STREET_NAME
POCK
STREET_TYPE
LN
City
STOCKTON
Zip
95205-
APN
17912011, -13, -14
ENTERED_DATE
4/7/2021 12:00:00 AM
SITE_LOCATION
3009 S POCK LN
RECEIVED_DATE
7/6/2022 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\lsauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1803
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Map ID MAP FINDINGS <br /> Direction <br /> Distance EDR ID Number <br /> Elevation Site Database(s) EPA ID Number <br /> MARCIS DIESEL SERVICE INC (Continued) 1000686605 <br /> programs may take into consideration of each employee. Immediately <br /> prepare or update the facility's training program,log into the <br /> California Environmental Reporting System(CERS)at <br /> http://cers.calepa.ca.gov/,upload the correct or updated information, <br /> and submit to the EHD for approval.This is a Class II violation. <br /> Violation Division: San Joaquin County Environmental Health <br /> Violation Program: HMRRP <br /> Violation Source: CERS <br /> Site ID: 157372 <br /> Site Name: STOCKTON DIESEL SERVICE INC <br /> Violation Date: 02-03-2016 <br /> Citation: 22 CCR 15 66265.192(h)-California Code of Regulations,Title 22, <br /> Chapter 15,Section(s)66265.192(h) <br /> Violation Description: Failure to obtain and maintain a written assessment reviewed and <br /> certified by an independent,qualified,professional engineer stating <br /> the new hazardous waste tank system has sufficient structural <br /> integrity,is acceptable for the transferring,storing and treating of <br /> hazardous waste,and that the tanks and containment system including <br /> the foundation,structural support,seams,connections,and pressure <br /> controls(if applicable)are suitably designed and that the tank <br /> system has sufficient structural strength,compatibility with the <br /> waste(s)to be transferred,stored or treated,and corrosion <br /> protection so that it will not collapse,rupture,or fail.This <br /> assessment shall be obtained prior to placing the tank system in <br /> service,and shall be kept on file at the facility.The tank <br /> assessment shall be good for five years.This assessment shall also <br /> include,at a minimum,the following information:(1)Design <br /> standard(s)according to which the tank(s)and ancillary equipment are <br /> or will be constructed;(2)Hazardous characteristics of the waste(s) <br /> to be handled;(3)For new tank systems or components in which the <br /> external shell of a metal tank or any external metal component of the <br /> tank system is or will be in contact with the soil or with water,a <br /> determination by a corrosion expert of:(A)Factors affecting the <br /> potential for corrosion,including but not limited to: 1.Soil <br /> moisture content;2.Soil pH;3.Soil sulfides level;4.Soil <br /> resistivity;5.Structure to soil potential;6. Influence of nearby <br /> underground metal structures(e.g.,piping);7.Stray electric <br /> current;and 8.Existing corrosion-protection measures(e.g.,coating, <br /> cathodic protection),and(B)The type and degree of external <br /> corrosion protection that are needed to ensure the integrity of the <br /> tank system during the use of the tank system or component,consisting <br /> of one or more of the following: 1.Corrosion-resistant materials of <br /> construction such as special alloys or fiberglass-reinforced plastic; <br /> 2.Corrosion-resistant coating(such as epoxy or fi <br /> Violation Notes: Returned to compliance on 05/10/2016. Facility does not have a tank <br /> assessment for the 500 gallon used oil and the used antifreeze tanks <br /> tank.The owner or operator of a hazardous waste tank shall obtain a <br /> written assessment reviewed and certified by an independent, <br /> qualified,professional engineer,registered in California attesting <br /> that the system has sufficient structural integrity,is acceptable for <br /> the transferring,storing,and treating of hazardous waste,and that <br /> the tanks and containment system are suitably designed. Immediately <br /> have an assessment prepared for the used oil and used antifreeze <br /> tanks.Submit a schedule showing when this will be accomplished to the <br /> EHD. <br /> Violation Division: San Joaquin County Environmental Health <br /> TC6327721.2s Page 155 <br />
The URL can be used to link to this page
Your browser does not support the video tag.