Laserfiche WebLink
Map ID MAP FINDINGS <br /> Direction <br /> Distance EDR ID Number <br /> Elevation Site Database(s) EPA ID Number <br /> AMERICAN PILEDRIVING EQUIP INC (Continued) S124780912 <br /> (3/19/14)was found without a signed off copy from the destination <br /> facility.Hazardous waste generators shall retain copies of all <br /> manifests signed off by the destination facility on site for three <br /> years and have them readily available for review. If the generator did <br /> not receive a copy of the manifest with the handwritten signature of <br /> the owner or operator of the facility to which the generatorG s waste <br /> was submitted within 60 days of the date the waste was accepted by the <br /> initial transporter,the generator shall submit a legible copy of the <br /> missing manifest,with some indication that the generator has not <br /> received confirmation of delivery.This information shall be submitted <br /> to:DTSC Report Repository Generator Information Services Section P.O. <br /> Box 806 Sacramento,CA 95812-0806 Immediately locate a copy of the <br /> missing manifest or prepare and submit the required information to <br /> DTSC.Submit to the EHD a copy of the signed off[Truncated] <br /> Violation Division: San Joaquin County Environmental Health <br /> Violation Program: HW <br /> Violation Source: CERS <br /> Site ID: 563066 <br /> Site Name: AMERICAN PILEDRIVING EQUIP INC <br /> Violation Date: 01-24-2020 <br /> Citation: 40 CFR 1 265.33-U.S.Code of Federal Regulations,Title 40,Chapter <br /> 1,Section(s)265.33 <br /> Violation Description: Failure to test and maintain as necessary all facility communications <br /> or alarm systems,fire protection equipment,spill control equipment, <br /> and decontamination equipment to assure its proper operation in time <br /> of emergency. <br /> Violation Notes: Returned to compliance on 02/24/2020.OBSERVATION:-Oily liquid and <br /> rags were observed inside the secondary containment for three 55 <br /> gallon drums of used oil.-Oily pads were observed in the secondary <br /> containment tray under the 55 gallon drum of drained used oil filters. <br /> REGULATION GUIDANCE:All facility communications or alarm systems, <br /> fire protection equipment,spill control equipment,and <br /> decontamination equipment,where required,shall be tested and <br /> maintained as necessary to assure its proper operation in time of <br /> emergency.CORRECTIVE ACTION:Bring the secondary containment into <br /> proper working order by cleaning up the oily spills,rags and <br /> absorbent pads.Provide a corrective action statement to the San <br /> Joaquin County Environmental Health Department within 30 days. <br /> Violation Division: San Joaquin County Environmental Health <br /> Violation Program: HW <br /> Violation Source: CERS <br /> Site ID: 563066 <br /> Site Name: AMERICAN PILEDRIVING EQUIP INC <br /> Violation Date: 08-04-2015 <br /> Citation: 40 CFR 1 265.173-U.S.Code of Federal Regulations,Title 40,Chapter <br /> 1,Section(s)265.173 <br /> Violation Description: Failure to properly close hazardous waste containers when not in <br /> active use. <br /> Violation Notes: Returned to compliance on 08/24/2015. Four 55 gallon drums of used oil <br /> were observed with open bungholes.A black bucket of used oil was <br /> observed in the chemical storage area with no lid.All hazardous waste <br /> containers shall be closed at all times except when adding or removing <br /> waste. Immediately close these containers and ensure all hazardous <br /> waste containers are closed when not adding or removing waste. <br /> Violation Division: San Joaquin County Environmental Health <br /> TC6327721.2s Page 247 <br />