My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0014056
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
POCK
>
3009
>
2600 - Land Use Program
>
PA-2100031
>
SU0014056
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 9:36:37 AM
Creation date
4/7/2021 2:18:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0014056
PE
2666
FACILITY_NAME
PA-2100031
STREET_NUMBER
3009
Direction
S
STREET_NAME
POCK
STREET_TYPE
LN
City
STOCKTON
Zip
95205-
APN
17912011, -13, -14
ENTERED_DATE
4/7/2021 12:00:00 AM
SITE_LOCATION
3009 S POCK LN
RECEIVED_DATE
7/6/2022 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\lsauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1803
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Map ID MAP FINDINGS <br /> Direction <br /> Distance EDR ID Number <br /> Elevation Site Database(s) EPA ID Number <br /> J B HUNT TRANSPORT INC (Continued) S121773713 <br /> larger than 55 gallons. <br /> Violation Division: San Joaquin County Environmental Health <br /> Violation Program: APSA <br /> Violation Source: CERS <br /> Site ID: 395262 <br /> Site Name: J B HUNT TRANSPORT INC <br /> Violation Date: 01-18-2019 <br /> Citation: HSC 6.67 25270.4.5(a)-California Health and Safety Code,Chapter <br /> 6.67,Section(s)25270.4.5(a) <br /> Violation Description: Failure to discuss in the SPCC Plan procedures to test or inspect each <br /> aboveground container for integrity in accordance with industry <br /> standards: 1.On a regular schedule.2.After material repairs are <br /> made.3. By qualified personnel.4.The frequency and type of testing <br /> and inspections based on container size,configuration,and design. <br /> Violation Notes: Returned to compliance on 02/12/2019.The SPCC plan references the <br /> Steel Tank Institute(STI)SP-001 industry standard for inspections of <br /> the tanks.The SPCC plan does not address annual inspections as <br /> required by the STI SP-001 standard.An environmental equivalence <br /> claim addresses the required testing by certified STI SP-001 inspector <br /> and not the deviation from annual inspections by the facility. Each <br /> aboveground container shall be tested and inspected for integrity on a <br /> regular schedule and whenever repairs are made.The qualifications of <br /> personnel performing tests and inspections,frequency and type of <br /> testing and inspections that take into account container size, <br /> configuration,and design shall be determined in accordance with <br /> industry standards. Examples of these integrity tests include,but are <br /> not limited to:visual inspection,hydrostatic testing,radiographic <br /> testing,ultrasonic testing,acoustic emissions testing,or other <br /> systems of non-destructive testing.Comparison records and other <br /> records of inspections <br /> Violation Division: San Joaquin County Environmental Health <br /> Violation Program: APSA <br /> Violation Source: CERS <br /> Site ID: 395262 <br /> Site Name: J B HUNT TRANSPORT INC <br /> Violation Date: 01-18-2019 <br /> Citation: 22 CCR 15 66265.33-California Code of Regulations,Title 22,Chapter <br /> 15,Section(s)66265.33 <br /> Violation Description: Failure to test and maintain as necessary all facility communications <br /> or alarm systems,fire protection equipment,spill control equipment, <br /> and decontamination equipment to assure its proper operation in time <br /> of emergency. <br /> Violation Notes: Returned to compliance on 02/12/2019.An eye wash station near the <br /> trailer shop needs to be adjusted.There is currently not enough water <br /> pressure to flush the eyes.All facility communications or alarm <br /> systems,fire protection equipment,spill control equipment,and <br /> decontamination equipment,where required,shall be tested and <br /> maintained as necessary to assure its proper operation in time of <br /> emergency. Immediately begin this practice. <br /> Violation Division: San Joaquin County Environmental Health <br /> Violation Program: HW <br /> Violation Source: CERS <br /> Site ID: 395262 <br /> Site Name: J B HUNT TRANSPORT INC <br /> TC6327721.2s Page 32 <br />
The URL can be used to link to this page
Your browser does not support the video tag.