SYSTEM SET-UP REPORT (Page 2) <br /> T 3:DiesE,1 LEAK TEST HETHOD OUTPUT RELAY SETUP £VR%ISD SETUP <br /> PRODUCT CODE B - - - - - - - - - - - - - - - - - - - - - - <br /> THERMAL COEFF :.000450 TEST ON DATE. : ALL TANK <br /> TANK DIAMETER 96.00 JUL 23, 2010 R '1:91 <br /> TANK PROFILE 4 PTS START.TIME : DISABLED TYPE: EVk TYPE: VACUUM ASSIST <br /> FULL VOL 7950 TEST RATE :0.20 GAL,,HR STANDARD VACUUM) ASSIST TYPE <br /> 72.0 INCH VOL : 6828HEALY VAC <br /> 48.0 INCH VOL 4299 DUR/�T(ON 2 HOURS' NORMALLY CLOSED <br /> 24.0 INCH VOL '1629 TST EARLY STOP:DISABLED TANS: #: 2 NOZZLE MAX: 1 .1155 RANGE <br /> MIN: 0.95 <br /> FLOAT SIZE: 4.0 IN LEAK TEST REPORT FORMAT VAPOR PROCESSOR TYPE <br /> NORMAL IN-TANK ALARMS NONE <br /> WATER WARNING 1 .0 — T 2:LOW PRODUCT ALARM <br /> HIGH WATER LIMIT: 2.0 LIQUID SENSOR SETUP LIQUID SENSOR ALMS <br /> - - - - - - - - - - - - L ;:FUEL ALARM ANALYSIS TIMES <br /> MAX OR LABEL VOL: 7950 L 2:SENSOR OUT ALARM TIME: 1.0:00 All <br /> OVERFILL LIMIT 90% L 1:DIESEL STP L 2:SHORT ALARM DELAY 'NtINUTES: I <br /> 7155 TRI-STATE (SINGLE FLOAT) <br /> HIGH PRODUCT 95YCATEGORY : STP SUMP 1 SD SITE ALARMS <br /> 7552 ISD GROSS FRES FAIL ACCEPT HIGH ORVR: <br /> DELIVERY LIMIT 10% ISD DEGRD PRES FAIL DISABLED <br /> 795 L 2'91 STP ISD VAPOR LEAK FAIL <br /> TRI-STATE cSINGLE FLOAT) ISD VP FRES FAIL ISD HOSE TABLE <br /> LOW PRODUCT 600 CATEGORY : STP SUMP ID FP FL HL AA RR <br /> LEAK ALARM LIMIT: 99 ISD HOSE ALARMS _ <br /> SUDDEN LOSS LIMIT: 99 ALL:GROSS COLLECT FAIL �1 O1 Ol 02 OI 00 <br /> TANK TILT 0.00 L 3:87 STP ALL:DEGRD COLLECT FAIL 02 02 02 02 01 00 <br /> PROBE OFFSET 0.00 TRI-STATE (SINGLE FLOAT) ALL:FLOW COLLECT FAIL 03 03 03 02 02 00 <br /> CATEGORY : STP SUMP 04 04 04 02 02 00 <br /> SIPHON MANIFOLDED TANKS k 2:87 <br /> T#: NONE . L 4:87 ANNULAR TYPE: ISD AIRFLOW METER MAP <br /> STANDARD ID SERIAL NUM LABEL <br /> LINE MANIFOLDED TANKS TRI-STATE (SINGLE FLOAT) NORMALLY CLOSED <br /> T#: NONE CATEGORY : ANNULAR SPACE -1 39364 1 2936-'- _-1-2 <br /> -2222-- <br /> TANK #: 1 -- <br /> 75450 3-4 <br /> LEAK MIN PERIODIC: 0% <br /> 0 L 5:91 ANNULAR IN-TANK ALARMS <br /> TRI-STATE (SINGLE FLOAT) T 1:LOW PRODUCT ALARM ISD FUEL GRADE HOSE MAP <br /> LEAK MIN ANNUAL 0% CATEGORY : ANNULAR SPACE 1 2 3 4 <br /> 0 LIQUID SENSOR ALMS FP_MHH-MHH MHH -- -AA--- <br /> L 3:FUEL ALARM O1 401 901 501 0 U I <br /> PERIODIC TEST TYPE L 6:DIESEL ANNULAR L 3:SENSOR OUT ALARM 02 402 902 502 0 U 1 <br /> STANDARD TRI-STATE (SINGLE FLOAT) L 3:SHORT ALARM 03 403 903 503 0 U 2 <br /> CATEGORY ANNULAR SPACE ISL, SITE ALARMS 04 404 904 504 0 U 2 <br /> ANNUAL TEST FAIL. ISD GROSS PRES FAIL <br /> ALARM DISABLED ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL LABELTABLE <br /> PERIODIC TEST FAIL --J <br /> ALARM DISABLEDiSD HOSE ALARMS I : UNASSIGNED <br /> ALL:GROSS COLLECT FAIL 2: BLENDS <br /> GROSS TEST FAIL ALL.DEGRD COLLECT FAIL 3: REGULAR <br /> ALARM DISABLED ALL:FLOW COLLECT FAIL 4: WID GRADE <br /> 5: PREMIUM <br /> ANN TEST AVERAGING: OFF 6: GOLD <br /> PER TEST AVERAGINi : OFF R 3:DIESEL 7: BRONZE <br /> TYPE: 8: SILVER <br /> TANK TEST NOTIFY: OFF NOSTANDARD 9: BLEND2 <br /> RMALLY 'CLOSED 18: BLEND4 <br /> TNK TST SIPHON BREAKOFF TANK #: 3 <br /> DELIVERY DELAY 5 MIN PMC SETUP <br /> PUMP THRESHOLD 10.00% IN-TANK ALARMS PMC VERSION: 01 .03 <br /> T 3:LOW PRODUCT ALARM <br /> VAPOR PROCESSOR TYPE <br /> LIQUID SENSOR ALMS NONE <br /> L 1 :FUEL ALARM <br /> .L 1 :SENSOR OUT ALARM PROCESSOR _CONTROL LEVEL: <br /> I 1:SHORT ALARM NONE <br /> SOFTWARE REVISION LEVEL <br /> SMARTSENSOR SETUP VERSION 330.01 <br /> - - - - - - - - - - - SOFTWARE# 346330-100-B <br /> CREATED - 10.07.23.17.25 <br /> s 1 :1-2 <br /> CATEGORY AIR FLOW ME S-MODULE# 330160-004-a <br /> SYSTEM FEATURES: <br /> s 2:3-4 PERIODIC I N-TANI' TESTS <br /> CATEGORY AIR FLOW MET ANNUAL IN-TANK TENTS <br /> ISD <br /> s 3:VAPOR PRESSURE <br /> CATEGORY VAPOR PRESSL <br /> ©2018 Walton Engineering,Inc. <br />