My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
800
>
2800 - Aboveground Petroleum Storage Program
>
PR0528616
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2025 4:22:02 PM
Creation date
4/13/2021 1:18:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0528616
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0018371
FACILITY_NAME
MCLANE FOODSERVICE DISTRIBUTION
STREET_NUMBER
800
STREET_NAME
PESCADERO
STREET_TYPE
AVE
City
TRACY
Zip
95304
APN
21307066
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
800 PESCADERO AVE TRACY 95304
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of aboveground petroleum storage act violations that <br />have not been addressed for MCLANE FOODSERVICE DISTRIBUTION as of April <br />06, 2021. <br />Open violations from January 09, 2019 inspection <br />Violation #711 -Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br />The two 15,000 gallon diesel tanks were not tested on schedule by qualified personnel. The SPCC plan calls for a <br />certified STI SP -001 integrity inspection "as soon as possible" since the tanks could not be dated. The SPCC plan <br />or the inspection checklists in th eSPCC plan do not address the inspection of interstitial space of double walled <br />tanks, as required by SP -001 inspection checklists. Each aboveground container shall be tested and inspected for <br />integrity on a regular schedule and whenever repairs are made. The qualifications of personnel performing tests <br />and inspections, frequency and type of testing and inspections that take into account container size, configuration, <br />and design shall be determined in accordance with industry standards. Examples of these integrity tests include, <br />but are not limited to: visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic <br />emissions testing, or other systems of non-destructive testing. Comparison records and other records of <br />inspections and tests must be maintained on site. Immediately conduct the necessary testing and submit a copy of <br />the test results to the EHD, or provide equivalence as allowed by CFR 112.7(a)(2). <br />❑ This violation was corrected ❑This violation will be corrected by (date): <br />❑ Supporting documents included <br />Describe actions taken or will be taken to correct violation: <br />Page 1 of 1 <br />
The URL can be used to link to this page