Laserfiche WebLink
blow <br /> • One dual-completed or co-located B/C Zone wells should be sited to the north of the site, <br /> approximately 250-feet north-northeast of well MW-13, along an approximate transect from the <br /> onsite release point to the water supply well located north of the site known as"Well 10". <br /> • There is 1,2-DCA data located in Geotracker that is missing from the GHD historical analytical <br /> data tables. The GHD tables should be updated to include missing data. <br /> Offsite Water Wells <br /> • Additional work should be conducted to identify any other water supply wells in the immediate <br /> vicinity and ensure residences located near the site are connected to a water service. <br /> • GHD will plan to complete a door-to-door survey to identify any other water supply wells in the <br /> immediate vicinity. <br /> • GHD will contact California Water Service of Stockton to determine if all local residences are <br /> currently connected to the municipal water supply. <br /> • CVRWQCB staff will review existing well logs. <br /> A Zone Well Destruction <br /> • GHD will review historical data to determine if any further groundwater analytical data is needed to <br /> define the extent of the release in A Zone wells. <br /> • If no further data is necessary, GHD will propose destruction of A Zone wells. <br /> Work Plan Addendum <br /> • GHD will present the findings and propose work described above in an addendum report to the <br /> November 30, 2020 Well Installation Work Plan by Arcadis. <br /> 11193145-Agency Meeting Notes.dou <br />