Laserfiche WebLink
FGL Environmental <br />Revision Date: 10/09/14 <br />Doc ID: 3D0900002_SOP_12-1.DOC <br />Page 1 of 1 <br />Inter- story Condition Upon Receipt (Attach to COC) 3 11�)V <br />Sample Receipt at• STK CC CH VI <br />1. Number of ice packages received: Shipping tracking # <br />2. Were samples received in a chilled condition? Temps: y,:7 / / / / <br />Surface water SWTR bact samples: A sample that has a temperature upon receipt of >10' C, whether iced or not, <br />should be flagged unless the time since sample collection has been less than two hours. <br />3. Do the number of bottles received agree with the COC? No N/A <br />4. Were samples received intact? (i.e. no broken bottles, leaks e No <br />5. VOAs checked for Headspace? es No <br />6. Were sample custody seals intact? Yes N <br />7. If required, was sample split for pH analysis? Yes No -- <br />S. Were all analyses within holding times at time of receipt? o <br />9. Verify sample date, time and sampler name <br />Sign and date the COC, place in a ziplock and put i e ice 'c e e samples. <br />Sample Receipt Review completed by (initials): <br />Sample Receipt at SP: <br />1. Were samples received in a chilled condition? Temps: <br />Acceptable is above freezing to 60 C. If many packages are received at one time check for ests/H.T.'s/rushes/ <br />2. Shipping tracking numbers: <br />3. Do the number of bottles received agree with the COC? Ts <br />No N/A <br />4. Were samples received intact? (i.e. no broken bottles, leaks etc.) No <br />5. Were sample custody seals intact? Yes No 1/ <br />Sign and date the COC, obtain LIMS sample numbers, select methods/tests and print labels. <br />Sample Verification, Labeling and Distribution: <br />1. Were all requested analyses understood and acceptable? es No <br />2. Did bottle labels correspond with the client's ID's? No <br />3. Were all bottles requiring sample preservation properly preserved? 'e No N/A FGL <br />]Exception: Oil & Grease, VOA and CM verified in lab] <br />4. VOAs checked for Headspace? Yes No FA <br />5. Have rush or project due dates been checked and accepted? Yes No <br />6. Were all analyses within holding times at time of receipt? es No <br />Attach labels to the containers and include a copy of the COC for lab delivery. <br />Sample Receipt, Login and Verification completed by (initials): <br />Discrepancy Documentation: <br />Any items above which are "No" or do not meet specifications (i.e. temps) must be resolved. <br />1. Person Contacted: Phone Number: <br />Initiated By: Date: <br />Problem: <br />Resolution: <br />2. Person Contacted: Phone Number: <br />Initiated By: <br />Problem: (3017919) <br />Resolution: San Joaquin County EHD <br />(Please use the back of this sheet for additional com SNIX2132598 <br />contacts) <br />ctc 0212312021 16:20:00 <br />