Laserfiche WebLink
r SANJOAQUIN <br />-I <br />COUNTY— <br />Greatness <br />U T <br />Greatness grows here, <br />Environmental Health Department <br />Swimming Pool Service Request Inspection Report <br />Time In: 1.50 pm <br />Time Out: 2:15 om <br />Name of Facility: WOODLAKE N CONDOMINIUMS OF SJ HOA <br />Date: 04/05/2021 <br />Address: 2400 EILERS LN , LODI 95242 <br />Requestor: MIKE MCDONELL, ADAMS POOL SPECIALTIES <br />Telephone: (916) 997-6787 <br />Program Element: 3602 - POOL/SPA REPAIR/REMODEL PLAN CHK <br />Request #: SR0083477 <br />Inspection Type: 523 - Plan Check/Report Review <br />I VIOLATIONS AND CORRECTIVE ACTIONS I <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR"pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />Pool and spa remodel <br />Pool <br />The handrails must be 28' to 36" for each step and deck to the top of the handrail. <br />Steps must be uniformed. Top step tread must be 14" to 18" and the rest of the steps must be 12" to 16". Step riser must be 6" <br />to 12". <br />For coping. The overhang for either bull -nosed coping or cantilevered decking shall not exceed 2 inches (51 mm) or be less <br />than 1 inch (25 mm) and shall not exceed 2'/2 inches (64 mm) in thickness. <br />Spa <br />The handrails must be 28' to 36" for each step and deck to the top of the handrail. <br />Steps must be uniformed. Top step tread must be 21" to 21" and the rest of the steps must be 12" to 16". Step riser must be 6" <br />to 12". <br />For coping. The overhang for either bull -nosed coping or cantilevered decking shall not exceed 2 inches (51 mm) or be less <br />than 1 inch (25 mm) and shall not exceed 2'/2 inches (64 mm) in thickness. <br />Ok to plaster. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: <br />EH Specialist: VIDAL PEDRAZA <br />EHD 36-01 Rev. 09/16/2020 <br />Name and Title: <br />Phone: (209) 616-3020 <br />Page 1 of 1 <br />FA0000780 SR0083477 SC523 04/05/2021 <br />Swimming Pool Service Request Inspection Report <br />