I . 00 me I l i Fl o vs, SVRS -�- t
<br /> a _
<br /> Intelligent Variable Speed Pump
<br /> a I'
<br /> ` 1
<br /> Reliable anti-body entrapment protection for Two key technology innovations drive
<br /> your peace of mind significant energy savings
<br /> With its built-in controller, proprietary software,and backup safety IntelliFlo vs+svgs pump includes exclusive,breakthrough motor Traditional pumps'one pre-set speed are almost always greater
<br /> features, IntelliFlo vs+svns pump provides the protection your pool or technology and controllable,variable-speed technology that than that needed to meet the health department turnover
<br /> spa requires with a virtually fail-safe,tamper proof solution. combine to drive down energy use and cost.And the savings requirements.
<br /> ate"' potential may be measured in thousands of dollars over its
<br /> With a variable speed pump,the optimum speed will almost
<br /> Safety Features long life. always be lower than the pre-set,unchangeable speeds of older
<br /> First,the Intel um uses an exclusive permanent• Meets ASME A112.19.17 standards,thus complying with pump p pumps.IntelliFlovs+svgs pump's eight settable,changeable
<br /> the Virginia Graeme Baker Pool Safety Act SVRS Requirements. magnet motor—like those used in hybrid cars—in place of a speeds{ranging from 1100 to 3450 RPMs}mean you can program
<br /> traditional induction motor.Permanent magnet motors are the exact flow requirements for each task,assuring the lowest
<br /> • Includes a built-in controller with proprietary software that
<br /> detects blockage and automatically shuts itself down fundamentally more energy efficient. energy use possible...adding to your savings.Plus with IntelliFlo
<br /> ,
<br /> within seconds. i Second,the IntelliFlo vs+SVRS pump includes a variable speed vs+svgs pump,you may be able to further reduce energy casts by
<br /> capability,along with digital controls and proprietary software reducing flow rates during non-pool use hours while maintaining
<br /> tr
<br /> • No SVRS calibration required:the blockage detection/shut down that allow custom programming tr optimum pump speeds for 24 hour-a-day filtration...at a much lower cost.Check with your
<br /> function is pre-programmed into the software.Once the $ local health department for requirements in your area.
<br /> �
<br /> specific tasks filtering,heating,cleaning,spa lets,etc.
<br /> IntelliFlo vs+SVRS pump is installed,the SVRS function works
<br /> without measurements,calculations and sensitivity settings
<br /> required with other devices. I r
<br /> • Unlike other devices. IntelliFlo vs+svgs pump's SVRS protection r � Here's just one comparative example: --
<br /> cannot be disabled.
<br /> Pump Annual Kilowatts Use Annual Electric Cost Savings Difference Engineered for exceptionally long life
<br /> • If for any reason IntelliFlo VS+SVRS pump's controller becomes r Q 24 hr/day Run Time 9.15 Kwh
<br /> IntelliFlo Vs+SVRS pump's permanent magnet motor produces far
<br /> inoperable,the pump will not run,providing an added layer i ,° 5p�° �°3° sq° � -
<br /> less heat and vibration than traditional induction motors.This not
<br /> of safety. t I kX, 2 HP 19,272 $2,891
<br /> I 4 only results in less stress and wear an pump components,but on
<br /> • Safety lock out feature(password protected)prevents settings l ♦, other equipment,too.Exclusive load-sensing software provides
<br /> from being changed by unauthorized personnel. -
<br /> IntelliFlo vs+SVRS 9,654 $1,448 $1,443 or 50% nearly instant priming which saves energy and reduces wear and
<br /> tear on the pump.Plus,built-in diagnostics protect the IntelliFlo
<br /> *Actual savings can vary.Example reflects savings for an average 30,000 gallon commercial pool operating 24 hours per day pump from the most common causes of premature pump failure—
<br /> at a flaw rate sufficient to perform a minimum 6 hourturnover.
<br /> overheating,freezing,and voltage irregularities.The result is you
<br /> can expect dramatically longer life and an even greater return on The only SVRS compliance solution that reduces
<br /> your investment. operating costs
<br /> The Virginia Graeme Balser Pool & Spa Safety Act of 2007--Summary pump Motor Speed vs.Power ConsumptionDon't just comply with the Virginia Graeme Baker Safety Act,
<br /> Other valuable features
<br /> tpp upgrade your pool with the intelligent IntelliFlo vs+svgs pump.
<br /> This new federal law was enacted to help prevent suction entrapment Single-and two-drain systems less than 3 feet apart that fail to Why slower is better IntelliFlo vs+svfls pump anticipates and solves other pool operating This pump not only meets safety requirements,it provides longer,
<br /> injuries and becomes effective December 19,2008.The requirements for meet one of the above requirements must be updated by adding, The surprising secret to minimizin 8o challenges: trouble-free service,and may save thousands of dollars in utility
<br /> p g g pump energy costs is to costs over its long life.
<br /> public swimming pools,spas,and wading pools are summarized below 1)Safety Vacuum Release System(SVHSI,2)Suction-Limiting Vent operate at the lowest speed needed to accomplish a job. It takes °' • Easy to program and monitor:simple push-button controls and
<br /> and must be met before these facilities can be operated after that date. System,3)Gravity Drainage System,4)Automatic Pump Shut-Off far fess energy to move water slowly than quickly.Why? Because 60 clear LCD readouts show stratus and text alerts to make
<br /> Drain Cover Requirements New drain covers certified to ASME ANSI System,5)Drain Disablement,or 61 Other Systems determined by
<br /> q / there's lower resistance In the filter,accessories and plumbing a operation a cinch.
<br /> Consumer Product Safety Commission to be equally effective. system.Even with only modest pump speed reductions,the effect
<br /> Al 12.19.8-2007 must be installed. a 4° For more information on IntelliFlo vs+SVRS, contact
<br /> Another option is to split the single drain into actual-drain system • Ability to set minimum and(maximum speeds: IntelliFlo will only your service provider, call Pentair Water Pool and
<br /> on electricity usage can be dramatic. In fact,reducing pump motor �0 operate within the ranges you set to help assure safe operation
<br /> Backup System Requirements-Suction piping for each pump must be with at least 3 feet of separation. speed by 25%actually reduces the power needed by 58%of Spa or visit www.svrspttmp.com today.
<br /> inspected and will be considered in compliance with the federal law if: and long equipment life.
<br /> 1)no submerged drains connect to the pump,or 21 there are two drains For more information about the Virginia Graeme Baker Pool what's consumed at the higher speed.A good analogy is your car: 0
<br /> at least 3 feet apart,or 3)there is a single"unblockable"drain.An and Spa Safety Act and how to comply, review the U.S. you get much better gas mileage at 30 mph than at 90 mph.The • Built-in clock and timer:Ohsoletes the need for an added time
<br /> unblockable drain includes a sump under the cover that is larger than 18 Consumer Product Safety Commission's interpretation posted same is true with pool pumps—run slower to reduce energy used. a 20 40 60 80 ion clock or expensive controller
<br /> inches by 23 inches,or a channel type drain with a diagonal open area of at: http;//www.cpsc.gov/phth/vgpsa.pdf. %RPM
<br /> This graph shows the huge increase In energy consumption as pump speed increases.
<br /> at least 29 Inches. Slow dawn the pump and you cut energy costs dramatically.
<br />
|