Laserfiche WebLink
SAN JOAQUIN <br />-----COUNTY -- <br />Environmental Health Department <br />FA0003624 PR0231225 SC001 06/09/2020 <br />EHD 23-01 Rev. 9/16/2020 Page 3 Of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue � Stockton, California 95205 � T 209 468-3420 � F 209 464-0138 � www.sjgov.org/EHD <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />CANEPAS CAR WASH <br />Facility Address: <br />6230 PACIFIC AVE, STOCKTON <br />Date: <br />June 09, 2020 <br />UST System Observations <br />312 <br />HSC 25290.2(d) <br />Monitoring system incapable of detecting entry into secondary containment (Jul 2003 -Jun 2004) <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />313 <br />HSC 25290A (d) <br />Monitoring system incapable of detecting entry into secondary containment (post -Jul 2004) <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />314 <br />315 <br />CCR 2631(8), 2632(c) <br />(2) <br />HSC 25290.1(e) <br />Failure to continuously monitor interstitial space with audible -visual alarm system (pre -Jul 2004) <br />Failure to maintain interstitial space to detect leaks before release to environment (post -Jul 2004) <br />❑ <br />❑ <br />V <br />V <br />❑ <br />❑ <br />R <br />R <br />❑ <br />❑ <br />COS <br />COS <br />316 <br />317 <br />CCR 2636, 2643(c)(1), <br />2666(f) <br />CCR 2636(f)(2) <br />Failure to install a line leak detector <br />Failure of the line leak detector to detect a 3.0 gph leak at 10 psi and restrict or shut off flow <br />❑ <br />❑ <br />V <br />V <br />❑ <br />❑ <br />R <br />R <br />❑ <br />❑ <br />COS <br />COS <br />318 <br />CCR 26359 2637.11 <br />2665, 2712 <br />Failed to meet spill container requirements <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />319 <br />CCR 2635, 2637.2, <br />2665,2712 <br />Failure to comply with overfill prevention equipment requirements <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />320 <br />CCR 2635(c)(1) <br />Overfill prevention was overridden <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />321 <br />HSC 25299(a)(9) <br />Leak detection equipment disabled or tampered with <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />322 <br />CCR 2717A (g) <br />Removed, defaced, altered, or otherwise tampered with red tag <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />323 <br />324 <br />CCR 2717.1(f); HSC <br />25292.3(c) <br />HSC 25292.3(c)(1)(C) <br />Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST <br />Allowed dispensing from a UST that has a red tag affixed to the fill pipe <br />❑ <br />❑ <br />V <br />V <br />❑ <br />o <br />R <br />R <br />❑ <br />❑ <br />COS <br />COS <br />325 <br />CCR 2635,2636(b), <br />2662, 2712 <br />Failure to comply with the cathodic protection system requirements <br />❑ <br />V <br />❑ <br />R <br />a <br />COS <br />326 <br />CCR 2631(b&d), <br />2666(b&e) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />327 <br />CCR 2638(a), 2641 Q) <br />Leak detection equipment not installed/calibrated/operated/maintained per manufacturer instructions <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />CCR 2630, 2632, 2643, <br />2644.1 <br />Equipment or methods used to monitor the UST system are not certified by an independent third -party <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />L328 <br />329 <br />CCR 2631,1,2660(m) <br />UST system not compatible with the substance stored <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />330 <br />331 <br />CCR 2636(0,2666(c), <br />2666(f) <br />HSC 25281.6(a) <br />Failure of emergency generator line leak detector to restrict or shut off flow or trigger an alarm <br />Failure of unburied below -grade emergency generator system to meet exemption conditions <br />❑ <br />❑ <br />V <br />V <br />❑ <br />❑ <br />R <br />R <br />❑ <br />❑ <br />COS <br />COS <br />332 <br />HSC 25283.5(a) <br />Failure of unburied below -grade UST system to meet exemption conditions <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />333 <br />CCR 2666(b)(2) <br />Failure to upgrade single -walled pipe to double -walled interstitially monitored pipe when repaired <br />o <br />V <br />❑ <br />R <br />❑ <br />COS <br />334 <br />CCR 2670(b)(e)(f), <br />2671 <br />Failure to comply with temporary closure requirements <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />335 <br />HSC 25298; CCR 2670, <br />2672 <br />Failure to comply with all permanent closure requirements <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />336 <br />CCR 2638(0) 2641(1) <br />Failure to affix a tag/sticker on each monitoring equipment certified, repaired, or replaced <br />❑ <br />V <br />❑ <br />R <br />❑COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />402 <br />CCR 2636(a)(3), <br />2641(b) <br />CCR 2643(d) <br />Safe suction piping not properly sloped or check valve incorrectly located <br />Failure to conduct monitoring and maintain records for single -walled conventional suction (pre -1984) <br />❑ <br />❑ <br />V <br />V <br />❑ <br />❑ <br />R <br />R <br />❑ <br />❑ <br />COS <br />COS <br />403 <br />CCR 2643(d), 2661(f) <br />Failure to conduct 0.1 gph integrity test for single -walled conventional suction systems (pre -1984) <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />404 <br />CCR 2643(e), 2661(f) <br />Failure to conduct 0.1 gph test on single -walled gravity piping biennially or post repair (pre -1984) <br />❑ <br />V <br />❑ <br />R <br />❑ <br />COS <br />FA0003624 PR0231225 SC001 06/09/2020 <br />EHD 23-01 Rev. 9/16/2020 Page 3 Of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue � Stockton, California 95205 � T 209 468-3420 � F 209 464-0138 � www.sjgov.org/EHD <br />