My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
8020
>
2900 - Site Mitigation Program
>
PR0542234
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2021 9:36:04 AM
Creation date
4/26/2021 8:40:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0542234
PE
2960
FACILITY_ID
FA0024261
FACILITY_NAME
CALIFORNIA ARMY NATIONAL GUARD
STREET_NUMBER
8020
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206-3919
APN
17726004
CURRENT_STATUS
01
SITE_LOCATION
8020 S AIRPORT WAY
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAFETY DATA SHEET - Helium <br />SDS Number. 061A <br />FIRE-FIGHTING MEASURES <br />Suitable extinguishing media <br />Specific hazards <br />Special protective equipment <br />for fire-fighters <br />All known extinguishing media can be used. <br />Upon exposure to intense heat or flame, cylinder will vent <br />rapidly and or rupture violently. Product is nonflammable <br />and does not support combustion. Move away from <br />container and cool with water from a protected position. <br />Keep containers and surroundings cool with water spray. <br />Wear self contained breathing apparatus for fire fighting if <br />necessary. <br /> <br />ACCIDENTAL RELEASE MEASURES <br />Personal precautions : Evacuate personnel to safe areas. Wear self-contained <br />breathing apparatus when entering area unless <br />atmosphere is proved to be safe. Monitor oxygen level. <br />Ventilate the area. <br />Environmental precautions Do not discharge into any place where its accumulation <br />could be dangerous. <br />Prevent further leakage or spillage if safe to do so. <br />Methods for cleaning up Ventilate the area. <br />Additional advice If possible, stop flow of product. Increase ventilation to <br />the release area and monitor oxygen level. If leak is from <br />cylinder or cylinder valve, call the Air Products <br />emergency telephone number. If the leak is in the user's <br />system, close the cylinder valve, safely vent the pressure, <br />and purge with an inert gas before attempting repairs. <br />HANDLING AND STORAGE <br />Handling <br />Protect cylinders from physical damage; do not drag, roll, slide or drop. Do not allow <br />storage area temperature to exceed 50°C. Only experienced and properly instructed <br />persons should handle compressed gases. Before using the product, determine its <br />identity by reading the label. Know and understand the properties and hazards of the <br />product before use. When doubt exists as to the correct handling procedure for a <br />particular gas, contact the supplier. Do not remove or deface labels provided by the <br />supplier for the identification of the cylinder contents. When moving cylinders, even for <br />short distances, use a cart (trolley, hand truck, etc.) designed to transport cylinders. Do <br />not remove valve guards. Before connecting the container, check the complete gas <br />system for suitability, particularly for pressure rating and materials. Before connecting the <br />container for use, ensure that back feed from the system into the container is prevented. <br />Ensure the complete gas system is compatible for pressure rating and materials of <br />construction. Ensure the complete gas system has been checked for leaks before use. <br />Employ suitable pressure regulating devices on all containers when the gas is being <br />emitted to systems with lower pressure rating than that of the container. <br />Open valve slowly. If user experiences any difficulty operating cylinder valve discontinue <br />use and contact supplier. Close container valve after each use and when empty, even if <br />still connected to equipment. Never attempt to repair or modify container valves or safety <br />relief devices. Damaged valves should be reported immediately to the supplier. Close <br />valve after each use and when empty. Do not subject containers to abnormal mechanical <br />shocks which may cause damage to their valve or safety devices. Never attempt to lift a <br />cylinder by its valve guard. Do not use containers as rollers or supports or for any other • <br />purpose than to contain the gas as supplied. Never strike an arc on a compressed gas <br />cylinder or make a cylinder a part of an electrical circuit. Do not smoke while handling <br />product or cylinders. Never re-compress a gas or a gas mixture without first consulting the <br />supplier. Never attempt to transfer gases from one cylinder/container to another. Always <br />use backflow protective device in piping. Never use direct flame or electrical heating <br />devices to raise the pressure of a container. Containers should not be subjected to <br />temperatures above 50°C. Prolonged periods of cold temperature below -30°C should be <br />avoided. <br />Storage <br />Full containers should be stored so that oldest stock is used first. Containers should be <br />stored in a purpose built compound which should be well ventilated, preferably in the <br />open air. Stored containers should be periodically checked for general condition and <br />leakage. Observe all regulations and local requirements regarding storage of containers. <br />Protect containers stored in the open against rusting and extremes of weather. <br />Containers should not be stored in conditions likely to encourage corrosion. Containers <br />should be stored in the vertical position and properly secured to prevent toppling. The <br />container valves should be tightly closed and where appropriate valve outlets should be <br />capped or plugged. Container valve guards or caps should be in place. Keep containers <br />tightly closed in a cool, well-ventilated place. Store containers in location free from fire <br />risk and away from sources of heat and ignition. Full and empty cylinders should be <br />segregated. Do not allow storage temperature to exceed 50°C. Return empty containers <br />in a timely manner. <br />Technical measures/Precautions <br />Containers should be segregated in the storage area according to the various categories <br />(e.g. flammable, toxic, etc.) and in accordance with local regulations. Keep away from <br />combustible material. <br />Air Products South Africa (P4f) Ltd 2/4 HELIUM/Rev 2/2016-03
The URL can be used to link to this page
Your browser does not support the video tag.