Laserfiche WebLink
�auW 'GZ SAN J OAQ U I N Environmental Health Department <br /> P <br /> �o. , co <br /> NEhi <br /> COUNTY Jasjit Kang , RENS , Director <br /> Muniappa Naidu, REHS , Assistant Director <br /> I iF6 W Greatness grows here . <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Melissa Nissim , REHS <br /> Steven Shih , REHS <br /> July 12 , 2021 <br /> Deborah Jones <br /> Elite IV Contractors <br /> 2535 Wigwam Dr . <br /> Stockton , CA 95205 <br /> Re : National Petroleum SR0083838 <br /> 713 N . EI Dorado St . , Stockton , CA 95202 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to replace the 87 , 91 , and diesel drop tubes and shut- off valves (flappers ) on <br /> the underground storage tank ( UST) system at the above noted address . The permit has been <br /> approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustt sigov . org to arrange the following inspection appointments <br /> ( a 48 - hour notice is required for inspection appointments ) . <br /> a . Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume shut <br /> off. Verification of flapper functionality . Ensure that all pertinent tank charts and <br /> calculations are available for review at the time of inspection . <br /> b . Verification that ball float (s ) , if installed , do not interfere with the installed flapper valve . <br /> Please be aware that the facility cannot receive fuel in the 87 , 91 , and diesel tanks prior <br /> to the EHD inspection and approval . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) <br /> c . Possesses a valid , current certificate of training from the manufacturer(s ) of the <br /> component (s) being tested , repaired , or serviced <br /> 5 . The tank owner or operator shall log into the California Environmental Reporting System <br /> ( CERS ) at http : //cers . calepa . ca . gov/ and ensure all UST information is current . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 -3420 1 F 209 464 - 0138 1 www . sjgov . org /ehd <br />