My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2705
>
2300 - Underground Storage Tank Program
>
PR0231072
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2023 4:18:58 PM
Creation date
4/28/2021 8:35:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231072
PE
2361
FACILITY_ID
FA0002048
FACILITY_NAME
TESORO (SPEEDWAY) 68221
STREET_NUMBER
2705
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12121008
CURRENT_STATUS
01
SITE_LOCATION
2705 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection 0 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10411900 5/7/20 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Speedway 6187 <br /> Business Site Address City ZIP Code <br /> 2705 Country Club Stockton 95204 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Kris Bell (408)971-2445 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 485184 8833000 10/29/21 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> F.F.#1004933708 <br /> OPW#902968 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method 0Manufacturer Guidelines(Specify):UseFranklin Fueling <br /> ❑ Industry Code or Engineering Standard(Specify): <br /> ❑Engineered Method(Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages 1 <br /> TANK ID: (By tank number,stored product,etc.) 1-Regular 2-Premium 3-Diesel <br /> What is the tank inside diameter?(Inches) 96" 96" 96" <br /> Is the fill piping secondarily contained? ❑✓ Yes ❑ No 0 Yes ❑ No ❑Q Yes ❑ No ❑Yes ❑ No <br /> Is the vent piping secondarily contained? 0 Yes ❑ No ❑✓ Yes ❑ No 0 Yes ❑ No ❑Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) Frankling Fueling Frankling Fueling Frankling Fueling <br /> EBW EBW EBW <br /> What is the overfill prevention equipment response 0 Shuts Off Flow 0 Shuts Off Flow 0 Shuts Off Flow ❑Shuts Off Flow <br /> when activated? <br /> ❑ <br /> (Check all that apply.) ❑ ❑ ❑ <br /> Restricts Flow Restricts Flow Restricts Flow Restricts Flow <br /> ❑AN Alarm ❑A/V Alarm ❑A/V Alarm ❑AN Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes 0 No ❑Yes ❑✓ No ❑Yes ❑✓ No ❑Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 86" 89.75" 87.75" <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 0.9448% 0.9723% 0.9583% <br /> Is the overfill prevention in proper operating condition 0 Yes ❑Yes ❑Yes ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No(Specify in V.) 0 No(Specify in V.) 0 No(Specify in V.) ❑No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ✓❑ Pass ❑FaIF11 ❑ Pass ✓❑ Fail ❑ Pass 0 Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked"Fail'must be explained in this section. Any additional comments may also be provided here. <br /> Both Premium and Diesel Overfill are set above 95%-Failures. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3, Chapter 16, Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> if the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,AI/=Audible and Visual <br />
The URL can be used to link to this page
Your browser does not support the video tag.