My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2705
>
2300 - Underground Storage Tank Program
>
PR0231072
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2023 4:18:58 PM
Creation date
4/28/2021 8:35:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231072
PE
2361
FACILITY_ID
FA0002048
FACILITY_NAME
TESORO (SPEEDWAY) 68221
STREET_NUMBER
2705
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12121008
CURRENT_STATUS
01
SITE_LOCATION
2705 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r(-,y PEIIRP1200_17 _...__..-.-.-..-.----_._---.------__-_— <br /> explosion-proof may ignite flammable <br /> vapors. If a portable air compressor is <br /> used, it should be located at least 20 feet <br /> away from the venturi-eductor or outside <br /> any Class I, Division 1 area. <br /> ti <br /> 6.3.4 Preparation. <br /> 1.Remove and properly dispose of any liquid and $I <br /> debris (leaves, sediment and trash) in the spill <br /> bucket.Clean the spill bucket and examine it for <br /> damage, defects or improperly installed compo- <br /> nents. If there are loose components (e.g., loose <br /> band clamps or bolts),tighten these items before FIGURE 6-3. The vacuum test method can detect a spill <br /> performing the integrity test. If there are items bucket leak by measuring the change in vacuum level <br /> that must be repaired or replaced (e.g., deterio- during the test. <br /> rated gaskets/seals or drain valves), notify the <br /> owner/operator to obtain approval before pro- 6.3.5 Test Procedure. <br /> ceeding with the needed repairs. 1. Slowly apply a 1 a vacuum of 30 inches water <br /> 2.Examine the fill cap and adapter fitting for column to the spill bucket and close the valve. <br /> loose, missing or damaged parts and make nec- If a 30-inch water column vacuum cannot be <br /> essary repairs.Make sure that the seal on the fill attained, the spill bucket fails the test. See <br /> cap is present and in good condition. The cap Appendix B for pressure and vacuum conver- <br /> must fit securely and be leak-tight on the riser. sions. <br /> A leaking cap will result in a failed test. As an 2. Start the time-measurement device and record <br /> alternative to a tight-fill cap, use a plumber's <br /> the initial vacuum level shown on the gauge. <br /> plug in the fill riser. <br /> 3.The spill bucket drain valve,if present,must be 3.After 1 minute,record the ending vacuum level. <br /> leak-tight to pass the test. If the drain valve is Upon completion of the test, release the vacuum, <br /> not leak-tight, it may be removed and perma- remove the test apparatus and the gasketing mate- <br /> nently plugged. rial from the spill bucket and replace the original <br /> cover. <br /> NOTE: Before permanently plugging, ensure <br /> that local regulations allow the drain valve to 6.3.6 Pass/Fail Criteria. If the ending vacuum <br /> be permanently plugged. level is 26 inches water column or greater,the spill <br /> bucket passes the test. <br /> 4.Clean any contamination from the top surface <br /> of the spill bucket where the cover makes a seal If the ending vacuum level is less than 26 inches <br /> and line it with gasketing material. water column, the spill bucket fails the test. <br /> 5.Place the test cover on the spill bucket,confirm- 6.4 Double-Walled Spill Bucket Integrity Testing— <br /> ing that it makes a tight seal with the gasketing Vacuum Test Method. <br /> material. <br /> 6.4.1 Purpose. This method is used to test the <br /> 6. Connect the line from the vacuum source to the integrity of the primary and secondary containment <br /> adapter on the cover. of the double-walled spill bucket. <br /> 7.If the spill bucket is found to have cracks, loose 6.4.2 Description of Test. A partial vacuum is <br /> parts or separation of the bucket from the fill applied to the interstitial space between the primary <br /> pipe,it is not considered to be liquid-tight. This and secondary containment. The vacuum level is <br /> visually indicates a test failure. monitored for a 1-minute period. <br /> 6.4.3 Test Equipment. Test equipment shall <br /> include: <br /> peLorg <br />