My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BIRD
>
23623
>
1900 - Hazardous Materials Program
>
PR0529204
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2021 2:30:39 PM
Creation date
4/29/2021 2:14:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1900 - Hazardous Materials Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0529204
PE
1921
FACILITY_ID
FA0019471
FACILITY_NAME
SHIMMICK CONSTRUCTION CO INC
STREET_NUMBER
23623
Direction
S
STREET_NAME
BIRD
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25010003
CURRENT_STATUS
01
SITE_LOCATION
23623 S BIRD RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Hazardous Materials Program Inspection Report <br />Date: <br />April 27, 2021 <br /> Facility Address: <br /> 23623 S BIRD RD, TRACY <br /> Facility Name: <br /> SHIMMICK CONSTRUCTION CO INC <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 5 HSC 25505(a)(1) Failed to electronically submit hazardous materials inventory for all reportable materials on site. <br />OBSERVATION: The chemical inventory has not been annually certified/submitted as a part of the business plan. <br />The inventory section] was not submitted for the year of 2021. The inventory section has not been submitted since <br />1/2/2021. Obsolete federal hazard categories were found for all chemicals on the last submittal. <br />REGULATION GUIDANCE: Per H&SC 25508.2, the business owner/operator shall annually review and certify that <br />the business plan is complete, accurate, up-to-date and in compliance with Section 11022 of Title 42 of the United <br />States Code. An annual electronic submittal satisfies these requirements. The annual business plan shall be <br />submitted/certified by January 15 of each calendar year and may be submitted beginning November 1 of the <br />previous year. <br />CORRECTIVE ACTION: Immediately log into the CERS at http://cers.calepa.ca.gov/, review and submit/certify the <br />current information. <br />This violation was corrected on site. <br />This is a Class II violation. <br /> 6 HSC 25505(a)(2) Failed to electronically submit a site map with all required content. <br />OBSERVATION: The site map has not been annually certified/submitted as a part of the business plan. The site <br />map was not submitted for the year of 2021. The site map was not completed and submitted as part of the <br />business plan <br /> The site map has not been submitted since 1/2/2020. The site map is missing storm drain locations, loading areas, <br />and internal road locations. <br />REGULATION GUIDANCE: Per H&SC 25508.2, the business owner/operator shall annually review and certify that <br />the business plan is complete, accurate, up-to-date and in compliance with Section 11022 of Title 42 of the United <br />States Code. An annual electronic submittal satisfies these requirements. The annual business plan shall be <br />submitted/certified by January 15 of each calendar year and may be submitted beginning November 1 of the <br />previous year. <br />REGULATION GUIDANCE: A site map shall contain a north orientation, loading areas, internal roads, adjacent <br />streets, storm and sewer drains, access and exit points, emergency shutoffs, evacuation staging areas, hazardous <br />material handling and storage areas, and emergency response equipment. <br /> If a site map element is not applicable for your facility then list it on the map and label as “NA". <br />CORRECTIVE ACTION: Immediately log into the CERS at http://cers.calepa.ca.gov/, review and submit/certify the <br />current information. <br />This is a Class II violation. <br />FA0019471 PR0529204 SC001 04/27/2021 <br />EHD 19-01 Rev. 9/16/2020 Hazardous Materials Program OIRPage 2 of 4 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.