1245
>
2300 - Underground Storage Tank Program
>
PR0541906
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2022 8:18:13 AM
Creation date
4/30/2021 3:29:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0541906
PE
2351
FACILITY_ID
FA0024040
FACILITY_NAME
MANTECA CHEVRON
STREET_NUMBER
1245
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1245 N MAIN ST
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-- _ LEAK TEST METHOD Q 3:DIESEL <br /> T 3:DIESEL - - - - - - - - - - - - TYP:2.Oi3.0IN FIBERGLASS <br /> PRODUCT CODE 3 TEST ON DATE : ALL TANK 2.OIN DIA LEN: 50 FEET <br /> THERMAL COEFF : .000450 DEC: 13, 2019 <br /> TANK, DIAMETER 118.38 START TIME : DISABLED 3.OIN DIA LEN: 0 FEET <br /> TANK PROFILE 4 PTS TEST RATE :0.20 GAL/HR <br /> FULL VOL ` 7901 DURATION 2 HOURS SHUTDOWN RATE: 3.0 GPH <br /> 88.8 INCH VOL 6360 LOW PRESSURE SHUTOFF:NO <br /> 59.2 INCH VOL 3960 TST EARLY STOP:DISABLED LOW PRESSURE 0 PSI <br /> 29.6 INCH VOL 1550 LEAK TEST REPORT FORMAT <br /> T 3:DIESEL <br /> NORMAL DISPENSE MODE: <br /> FLOAT SIZE: 4.0 IN. STANDARD <br /> WATER MINIMUM 0.000 SENSOR: VENTED <br /> WATER WARNING 0.8 PRESSURE OFFSET: O.OPSI <br /> HIGH WATER LIMIT: 1 .5 MECHANICAL BLENDER: NO <br /> WATER ALARM FILTER: LOW <br /> MAX OR LABEL <br /> VOLUME 7901 <br /> HIGH PRODUCT PRESSURE LINE LEAK SETUP <br /> % MAX 95.0 - - - - - - - - - - - - <br /> (GALLONS) 7506 <br /> OVERFILL LIMIT Q 1 :87 UNLEADED <br /> (GALLONS) 711 TYP:2.0�3.OIN FIBERGLASS LINE LEAK LOCKOUT SETUP <br /> 2.0I N D I A LEN: 180 FEET - - - - - - - - - - - - <br /> IiELIVERY LIMIT LOCKOUT SCHEDULE <br /> MAX 10.0 3.OIN DIA LEN: 0 FEET DAILY <br /> (GALLONS) 790 SHUTDOWN RATE: 3.0 GPH START TIME: DISABLED <br /> LOW PRESSURE SHUTOFF:NO .TOP TIME DISABLED <br /> LOW PRODUCT LOW PRESSURE 0 PSI <br /> VOLUME 450 <br /> LEAK ALARM LIMIT: 99 T 1 :87 UNLEADED <br /> SUDDEN LOSS LIMIT: 99 DISPENSE MODE: <br /> TANK TILT 0.00 STANDARD <br /> PROBE OFFSET 0.00 SENSOR: VENTED <br /> PRESSURE OFFSET: O.OPSI <br /> SIPHON MANIFOLDED TANKS MECHANICAL BLENDER: NO <br /> T#: NONE <br /> LINE MANIFOLDED TANKS <br /> T#: NONE LIQUID SENSOR SETUP <br /> - - - - - - - - - - - - <br /> LEAK MIN PERIODIC: 0% L 1 :D1-2 DW2-1 <br /> • 0 DW SUMP 2-1 <br /> LEAK MIN ANNUAL 0; <br /> CATEGORY : DISPENSER PAN <br /> : <br /> 0 <br /> Q 2:91 UNLEADED L 2:D3-4 DW2-1 <br /> PERIODIC TEST TYPE DW SUMP 2-1 <br /> STANDARD TYP:2.0/3.OIN FIBERGLASS CATEGORY : DISPENSER PAN <br /> 2.OIN DIA LEN: 180 FEET <br /> ANNUAL TEST FAIL 3.OIN DIA LEN: 0 FEET <br /> ALARM DISABLED <br /> SHUTDOWN RATE: 3.0 GPH L 3:D5-6 DW2-1 <br /> PERIODIC TEST FAIL LOW PRESSURE SHUTOFF:NO DW SUMP 2-1 <br /> ALARM DISABLED LOW PRESSURE 0 PSI CATEGORY : DISPENSER PAN <br /> GROSS TEST FAIL <br /> AT c:91 UNLEADED <br /> ALARM DISABLED <br /> DISPENSE MODE: L 4:D7-8 DW2-1 <br /> ANN TEST AVERAGING: OFF STANDARD DW SUMP 2-1 <br /> PER TEST AVERAGING: OFF SENSOR: VENTED CATEGORY : DISPENSER PAN <br /> PRESSURE OFFSET: O.OPSI <br /> TANK TEST NOTIFY: OFF MECHANICAL BLENDER: NO <br /> TNK TST SIPHON BREAKOFF L 5:D9-10 DW2-1 <br /> DW SUMP 2-1 <br /> DELIVERY DELAY 1 MIN CATEGORY : DISPENSER PHN <br /> DIM THRESHOLD 10.00% <br />
The URL can be used to link to this page
Your browser does not support the video tag.