My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING/PERMITS_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1329
>
2200 - Hazardous Waste Program
>
PR0542875
>
BILLING/PERMITS_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2021 4:26:10 PM
Creation date
5/3/2021 4:23:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
BILLING/PERMITS
FileName_PostFix
2021
RECORD_ID
PR0542875
PE
2220
FACILITY_ID
FA0000293
FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health DepartmentSmall Quantity Hazardous Waste Generator Inspection ReportDate:February 19, 2020Facility Address:1329 Escalon Ave, EscalonFacility Name:Pershing Holdings, Inc. DBA Esclon ArcoSUMMARY OF VIOLATIONS(CLASS I, CLASS II, or MINOR - Notice to Comply)RemarksItem #605CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. OBSERVATION: Hazardous waste containers were observed on-site with incomplete labeling. The containers were: A 55 gallon blue steel drum of petroleum mix with water was observed in the dumpster area with no hazardous property, physical state and accumulation start date listed.REGULATION GUIDANCE: All hazardous waste containers shall be marked with the following information: the words “Hazardous Waste”, name and address of generator, hazardous properties, physical state, composition (contents), accumulation start dateCORRECTIVE ACTION: Immediately label the containers as required for hazardous waste. Provide a corrective action statement and supporting documentation to the San Joaquin County Environmental Health Department (EHD) within 30 days.This is a minor violation.608CCR 66266.130 Failed to properly manage used oil and fuel filters. OBSERVATION: This facility generates drained used metal oil filters. A complete three year bill of lading record for used oil filter recycling was not observed during the inspection. According to Mr. Sat Dhanda, technicians take the used oil filters away. REGULATION GUIDANCE: Persons generating, transporting, or receiving used metal oil filters shall use a bill of lading to record the transfer of used oil filters. Bills of lading must indicate generator, transporter, and receiving company names, addresses, telephone numbers, the quantity and size of used oil filter containers transferred, and the date of transfer. A copy of each bill of lading must be kept on the premises of the generator, transporter, and receiving facility where the used oil filters were handled. Copies of bills of lading shall be kept for a period of three years.CORRECTIVE ACTION: Immediately obtain all missing bill of lading recycling records that can be found. Used metal oil filters not stored, handled and disposed of according to this section are regulated as hazardous waste. Provide a corrective action statement, bill of lading recycling records and supporting documentation to the San Joaquin County Environmental Health Department (EHD) within 30 days.This is a minor violation.Overall Inspection Comments:An inspection checklist was provided to the facility operator at the time of inspection. The EHD has written the complete report on 02/27/2020 which replaces the intial checklistComplete and submit a copy of the Return to Compliance Certification form to the EHD with a statement documenting the corrective actions that have been or will be taken for each violation, and any supporting paperwork, by March 27, 2020.Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an FA0000293 PR0542875 SC001 02/19/2020EHD 22-01 Rev. 9/20/2019Small Quantity Hazardous Waste Generator OIRPage 6 of 71868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.