My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2285
>
2300 - Underground Storage Tank Program
>
PR0231111
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2021 8:57:42 AM
Creation date
5/4/2021 7:58:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231111
PE
2361
FACILITY_ID
FA0001659
FACILITY_NAME
QUIK STOP MARKET #039
STREET_NUMBER
2285
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
141-214-03
CURRENT_STATUS
01
SITE_LOCATION
2285 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report <br /> 6 . OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (one OPE per column) 87 91 <br /> Are both vent and tank riser piping F1 Yes ® Yes rl Yes Yes <br /> secondarily contained ? © No r] No © No © No <br /> OPE Model 61 /71SO 61 /71SO <br /> What is the OPE response when Shut off 0 Shut off © Shut off ! Shut off <br /> activated ? Flow Flow Flow Flow <br /> (Check all that apply. ) 0 Restricts © Restricts © Restricts © Restricts <br /> Flow Flow Flow Flow <br /> Audible rl Audible [M Audible rl Audible <br /> Alarm Alarm Alarm Alarm <br /> rl Visual 0 Visual © Visual rl Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping © Yes * 0 Yes * r] Yes * © Yes * <br /> that may interfere with the OPE operation ? [M No F71 No rl No © No <br /> At what level in the tank is the OPE set to <br /> 86 . 25 <br /> activate ? Inches from bottom of tank <br /> What is the percent capacity of the tank at 95 <br /> which the OPE activates ? <br /> Is the OPE in proper operating condition to F] Yes © Yes * rl Yes * r] Yes * <br /> respond when the stored substance © No © No 0 No © No <br /> reaches the designated regulatory level ? <br /> 7 . SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results © Pass © Pass © Pass © Pass <br /> © Fail Q Fail r] Fail rl Fail <br /> 8 . COMMENTS <br /> Describe all answers marked "No " or "Fail' and proposed remedy. <br /> List all monitoring equipment either replaced or repaired. <br /> unable to test the 91 drop tube due to bucket being sealed to face seal adaptor and my truck vice broke , return trip needed to try to remove drop tube . <br /> * Mark here if: <br /> rl Flow restrictors interfere with overfill prevention and equipment repairs required . <br /> Additional copies of this page may be attached. <br /> Attach tank chart(s), measurements, calculations, and In - Tank Setup report(s) <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.