My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1580
>
2300 - Underground Storage Tank Program
>
PR0231476
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 1:07:55 PM
Creation date
5/4/2021 8:00:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231476
PE
2361
FACILITY_ID
FA0000684
FACILITY_NAME
QUIK STOP MARKET #125
STREET_NUMBER
1580
Direction
W
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
259-090-21
CURRENT_STATUS
01
SITE_LOCATION
1580 W MAIN ST
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Overfill Prevention Equipment Inspection Report <br />6. OVERFILL PREVENTION EQUIPMENT DETAILS <br />Tank ID (one OPE per column) <br />87 <br />© Yes <br />91 <br />© Yes <br />Diesel <br />Q Yes <br />0 Yes <br />Are both vent and tank riser piping <br />secondarily contained? <br />rl No <br />© No <br />R7 No <br />0 No <br />OPE Model <br />What is the OPE response when <br />El Shut off <br />El Shut off <br />© Shut off <br />57 Shut off <br />activated? <br />Flow <br />Flow <br />Flow <br />Flow <br />(Check all that apply.) <br />© Restricts <br />EI Restricts <br />© Restricts <br />0 Restricts <br />Flow <br />Flow <br />Flow <br />Flow <br />© Audible <br />© Audible <br />FM Audible <br />0 Audible <br />Alarm <br />Alarm <br />Alarm <br />Alarm <br />El Visual <br />© Visual <br />Visual <br />Visual <br />Alarm <br />Alarm <br />Alarm <br />Alarm <br />Are flow restrictors installed on vent piping <br />© Yes* <br />Yes* <br />Yes* <br />Yes* <br />that may interfere with the OPE operation? <br />® No <br />® No <br />® No <br />r] No <br />At what level in the tank is the OPE set to <br />activate? Inches from bottom of tank <br />89 3/4" <br />89 3/4" <br />89 3/4" <br />What is the percent capacity of the tank at <br />95% <br />95% <br />95% <br />which the OPE activates? <br />Is the OPE in proper operating condition to <br />Yes <br />✓0 Yes* <br />© Yes* <br />0 Yes* <br />respond when the stored substance <br />© No <br />© No <br />© No <br />0 No <br />reaches the designated regulatory level? <br />7. SUMMARY OF TESTING RESULTS <br />OPE Inspection Results <br />Pass <br />Q Fail <br />0 Pass <br />© Fail <br />0 Pass <br />0 Fail <br />® Pass <br />E Fail <br />8. COMMENTS <br />Describe all answers marked "No" or "Fail" and proposed remedy. <br />List all monitoring equipment either replaced or repaired. <br />* Mark here if: <br />® Flow restrictors interfere with overfill prevention and equipment repairs required. <br />Additional copies of this page may be attached. <br />Attach tank chart(s), measurements, calculations, and In -Tank Setup report(s) <br />Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.