Laserfiche WebLink
REVISED MONITORING AND REP —ING PROGRAM ORDER NO. R5-2008-'c -10- <br />HJ BAKER & BRO. INC., MARTIN G, .ATING PARTNERSHIP, THE PORT 0, OCKTON, <br />AND METROPOLITAN STEVEDORE <br />MOLTEN SULFUR PROCESSING PLANTS <br />SAN JOAQUIN COUNTY <br />Historical and current monitoring data of the sulfur-contact water must be presented in <br />summary tables (laboratory reports are not considered to be summary tables) so that the <br />sample date, the constituents, the concentrations, and units are readily discernible; and <br />Signed hard copies of laboratory reports and chains-of-custody must be included. <br />D. Annual Monitoring Summary Report <br />The Discharger shall submit an Annual Monitoring Summary Report to the Central Valley W <br />Board covering the previous monitoring year by the Reporting Due Date shown in Table <br />Section A, above. The annual report must contain the transmittal letter, signed certificatio <br />statements, monitoring results, information required in the semiannual monitoring report, a <br />the additional information as defined below: <br />The Discharger must provide tabular summaries of all monitoring data collected duri <br />the year; <br />The Discharger must submit time versus concentration graphs. For each groundwate <br />monitoring well, the Discharger must submit time-series graphs showing analytical data <br />for all historical samples (i.e., 1991 through the current year). Each time-series gra <br />must plot the concentration of one constituent for one or more wells for the period o <br />record at a scale appropriate to show trends or variations in water quality. Graphs for <br />background wells must be plotted at the same scale as any other well. The graphs must <br />plot each datum, rather than plotting mean values. Log and semi-log graphs are not <br />acceptable for this requirement; <br />The Discharger must include a comprehensive discussion of its compliance record, any <br />planned corrective actions, and the results of any implemented corrective actions; <br />The Discharger must include a written summary of the monitoring results, indicating any <br />changes made or observed since the previous annual report; <br />The Discharger must submit hydrographs of each well for each quarter. The <br />hydrographs must show the elevation of groundwater with respect to the elevations of the <br />top and bottom of the screened interval and the elevation of the pump intake; <br />The Discharger must discuss any data gaps and potential deficiencies/redundancies in <br />the monitoring system or reporting program; <br />The Discharger must evaluate the groundwater monitoring parameters annually with <br />regards to the cation/anion balance, and the results must be graphically presented using <br />Stiff diagrams; and <br />h. The Discharger must submit a database with electronic Excel tables on a CD that <br />includes the historical and current analytical results, field parameters, the analyte, test <br />