Laserfiche WebLink
Robert Anderson <br /> February 4, 1993 <br /> Page 3 <br /> and Cat 825 compactor or equivalent are capable of mixing and <br /> compacting single loose soil lifts of over 16 inches. <br /> To demonstrate that the lower portion of the lift meets the <br /> construction criteria, a nuclear gage with a 12 inch probe will be <br /> used for compaction testing. As for permeability, the actual <br /> laboratory sample will be carved out of the center 6 inches of the <br /> sample. See Figure A for additional details. <br /> Comment 5: <br /> "A Final Test Pad construction, testing, and evaluation report must <br /> be submitted for incorporation into the Final Closure Plan. " <br /> Response: <br /> A Final Test Pad report will be prepared and incorporated into the <br /> Final Closure Plan as requested. <br /> Sincerely, <br /> GABRIEL KARAM, P.E. <br /> Senior Solid Waste Engineer <br /> GK:vj <br /> R: IVIRGINIAILETTERSITESTPADZ .RA <br /> Attachments <br /> LA 11729E <br /> c: Ed Padilla, SREHS <br /> Environmental Health Division <br />