My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_1992-1993
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
14750
>
4400 - Solid Waste Program
>
PR0440007
>
CORRESPONDENCE_1992-1993
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2021 4:34:37 PM
Creation date
5/7/2021 8:39:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
1992-1993
RECORD_ID
PR0440007
PE
4434
FACILITY_ID
FA0000595
FACILITY_NAME
HARNEY LANE LANDFILL
STREET_NUMBER
14750
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06503006
CURRENT_STATUS
01
SITE_LOCATION
14750 E HARNEY LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t f' <br /> kn KLEINFELDER <br /> File No. 20-1008-49.001 <br /> December 9, 1993 <br /> SUMMARY OF DAILY SDRI READINGS ("SM" TEST PAD) <br /> Elapsed <br /> Time Average <br /> Between Weight Water <br /> Reading Change Temperature Permeability <br /> Date (hours) (gram) (Degrees F) (cm/sec) <br /> 11/18/93 25.70 69.2 57 2.6x10-' <br /> 11/19/93 22.85 120.9 57 5.0x10' <br /> 11/20/93 24.90 104.9 56 4.0x10-' <br /> 11/21/93 21.10 95.5 54 4.3x10' <br /> 11/22/93 27.72 105.1 54 3.6x10-' <br /> 11/23/93 20.25 113.2 54 5.3x10' <br /> 11/24/93 23.97 94.1 51 3.7x10'' <br /> 11/25/93 23.93 101.3 50 4.0x10-' <br /> 11/26/93 24.15 91.3 50 3.6x10' <br /> 11/27/93 23.80 95.0 49 3.8x10' <br /> 11/28/93 19.93 77.5 48 3.7x10' <br /> CONCLUSIONS <br /> Based on the results of our additional SDRI permeability, the SM test pad meets-permeability <br /> specifications. It is our opinion that an SDRI test on the ML test pad (which contains more clay <br /> and fines than the SM test pad) would most likely indicate an even lower permeability. For this <br /> reason, we do not recommend further SDRI testing. We recommend the procedures outlined <br /> in our July 8, 1993 report be used for barrier construction. <br /> Copyright 1993 Kteinfetder, Inc. Page 4 of 5 <br />