My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1905
>
2900 - Site Mitigation Program
>
PR0518600
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2021 4:55:47 PM
Creation date
5/11/2021 4:35:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0518600
PE
2960
FACILITY_ID
FA0013996
FACILITY_NAME
CROP PRODUCTION SERVICES
STREET_NUMBER
1905
Direction
N
STREET_NAME
BROADWAY
City
STOCKTON
Zip
95205
APN
14315004
CURRENT_STATUS
01
SITE_LOCATION
1905 N BROADWAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE OF CONTENTS <br /> 1.0 INTRODUCTION............................................................................................................. 1 <br /> 1.1 Objectives......................................................................................................................................1 <br /> 2.0 SITE DESCRIPTION....................................................................................................... 1 <br /> 3.0 SITE GEOLOGY AND HYDROGEOLOGY..................................................................... 1 <br /> 3.1 Geology.........................................................................................................................................1 <br /> 3.2 Hydrogeology................................................................................................................................2 <br /> 4.0 CHEMICALS OF CONCERN.......................................................................................... 2 <br /> 5.0 PREVIOUS REMEDIATION............................................................................................ 2 <br /> 5.1 Cap and Liner System Installation ................................................................................................2 <br /> 5.2 2006 Pilot Test..............................................................................................................................3 <br /> 6.0 PILOT TEST AND MONITORING WELL INSTALLATION............................................. 3 <br /> 6.1 Remediation Technology ..............................................................................................................3 <br /> 6.1.1 Enhanced Bioremediation.....................................................................................................3 <br /> 6.1.2 Chemical Degradation...........................................................................................................4 <br /> 6.1.3 Pilot Test Injections and Monitoring......................................................................................4 <br /> 6.1.4 Performance Monitoring........................................................................................................4 <br /> 6.2 Permitting......................................................................................................................................5 <br /> 6.2.1 Monitoring Well Permits........................................................................................................5 <br /> 6.2.2 Notice of Intent for Injections.................................................................................................5 <br /> 6.3 Health and Safety Plan .................................................................................................................5 <br /> 6.4 Utility Clearance............................................................................................................................5 <br /> 6.5 Monitoring Well Installation ...........................................................................................................5 <br /> 6.5.1 Well Development.................................................................................................................6 <br /> 6.5.2 Well Surveying ......................................................................................................................6 <br /> 6.6 Decontamination and Waste Management...................................................................................6 <br /> 7.0 GROUNDWATER MONITORING AND SAMPLING PROGRAM.................................... 6 <br /> 7.1 Schedule and Frequency..............................................................................................................6 <br /> 7.2 Well Designations .........................................................................................................................6 <br /> 7.3 Groundwater Sampling and Analysis............................................................................................7 <br /> 8.0 WELL DESTRUCTION ................................................................................................... 7 <br /> 8.1 Well Destruction Permitting...........................................................................................................7 <br /> 8.2 Well Destruction Procedure ..........................................................................................................8 <br /> 9.0 REPORTING AND SCHEDULING.................................................................................. 8 <br /> 10.0 REFERENCES................................................................................................................ 9 <br /> CPS Stockton, California i <br /> Pilot Test Work Plan <br />
The URL can be used to link to this page
Your browser does not support the video tag.