Laserfiche WebLink
'oVr`K`. dANJOAQUIN Environmental Health Department <br /> COUNT Y-- <br /> - Time In: 9,17 am <br /> Greotness grows he,L. <br /> Time Out: 10:56 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: SAMARA MOBILE COURT Date: 07/09/2019 <br /> Address: 2340 SANGUINETTI LN, STOCKTON 95205 <br /> OwnerlOperator: DENHOY, BALWANT&SUKHWANT Telephone: (209)466-2461 <br /> Program Element: 3611 -PUBLIC POOLISPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION-Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code sections)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545_ <br /> #3 Safety Signs <br /> OBSERVATIONS:Pool power is off permanently. Post"No swimming after dark"today. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole, gate,or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:Pool ladder is loose. Fix today. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Pool skimmers are lacking weir gates. Provide in 3 days. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (GBC 3136B) <br /> #27 Pool Equipment Room <br /> OBSERVATIONS:i observe 3 holes in equipment room ceiling. Seal in 2 weeks. <br /> CALCODE DESCRIPTION:Pool operator shall keep ancillary facilities well maintained. (CCR 65535)All filters, valves,pumps, strainers <br /> and equipment shall be readily accessible for repair and replacement. (CBC 31232) <br /> #35 Flow Meters <br /> OBSERVATIONS:Flow meter is not functioning. Replace in 3 days. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 3125B) <br /> EA0001744 PRC360123 SC001 07/0912019 <br /> EH❑35-01 Rev.96130/15 Page 1 of 2 Swimming Pcol OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />