COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SWAIN
>
1437
>
1600 - Food Program
>
PR0360167
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2021 2:46:40 PM
Creation date
5/14/2021 2:43:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0360167
PE
3611
FACILITY_ID
FA0001531
FACILITY_NAME
VICTORIAN VILLAGE CONDOMINIUM ASSN
STREET_NUMBER
1437
Direction
W
STREET_NAME
SWAIN
STREET_TYPE
RD
City
STOCKTON
Zip
95207
APN
09753004
CURRENT_STATUS
01
SITE_LOCATION
1437 W SWAIN RD
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIU I Environmental Health Department <br /> - i COUNTY I <br /> Greotness grows here Time In: 10.10 am <br /> Time Out: 10:35 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: VICTORIAN VILLAGE CONDOMINIUM ASSN Date: 05/14/2021 <br /> Address: 1437 W SWAIN RD, STOCKTON 95207 <br /> Owner/Operator: VICTORIAN VILLAGE CONDO ASSN Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #4 Safety Equipment <br /> OBSERVATIONS:Attach a rope the width of the poll in length. Correct prior to using the pool. <br /> CALCODE DESCRIPTION:Safety equipment shall be provided, maintained,readily visible,and available for use.Pools shall have at <br /> minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br /> rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br /> (CCR 65540) <br /> #5 Restrooms and Showers <br /> OBSERVATIONS:There is debris on the showers floor. Clean prior to using the pool. <br /> CALCODE DESCRIPTION:Pool operator shall ensure the following facilities are maintained and kept clean:showers, toilets, dressing <br /> facilities, drinking fountains,diaper-changing stations, floors, walls,partitions, doors,and lockers. Showers(except outside)shall be <br /> provided with soap in dispensers. Toilet facilities shall be provided with toilet tissue,hand soap, and paper towels or hot air blowers in <br /> permanently installed dispensers.Pool operator shall provide a minimum of one waste receptacle in each toilet facility. Wooden slats, <br /> duckboards and footbaths are prohibited. (CCR 65535, 65551)Showers and lavatories shall be provided with hot and cold water faucets. <br /> Maximum water temperature at showers and lavatories shall not exceed 110`F. (CBC 31168) <br /> #13 Cyanuric Acid Concentration <br /> OBSERVATIONS:Cyanuric acid is at 100 ppm.Adjust and maintain bellow 100 ppm prior to using the pool. Ideal 30 ppm to <br /> 50 ppm. Test monthly. <br /> CALCODE DESCRIPTION:Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> #35 Flow Meters <br /> OBSERVATIONS:The flow meters has calcium like deposit on it and it is not able be read. Clean/repair by today. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 31256) <br /> FA0001531 PR0360167 SCO01 05/14/2021 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.