Laserfiche WebLink
SAN <br /> J O a Q U I N Environmental Health Department <br /> C0U ;N i Y <br /> Food Program Official Inspection Report <br /> Facility Name and Address: CHUBBY'S DINER, 265 W LOUISE , MANTECA 95336 <br /> #33 Nonfood Contact Surfaces Clean <br /> OBSERVATIONS:Hood filter, exterior surfaces of the cooking equipment at the cooking area, exterior and interior surfaces <br /> of 2 D True freezer by the cooking area and interior surfaces of reach in coolers at the cook line, have grease accumulation, <br /> splatter and sticky food debris. Clean surfaces today and as needed. <br /> CALCODE DESCRIPTION:All nonfood contact surfaces of utensils and equipment shall be clean. (114115(c)) <br /> #34 Warewashing Facilites Maintained <br /> OBSERVATIONS:Hand sink at the waitress station, is not secured to the wall. Secure sink in 1 week. <br /> CALCODE DESCRIPTION:Food facilities that prepare food shall be equipped with warewashing facilities. Testing equipment and <br /> materials shall be provided to measure the applicable sanitization method. (I14067(f,g), 114099, 114099.3, 114099.5, 114101(a), <br /> 114101.1, 114101.2, 114103, 114107, 114125) <br /> #35 Equipment/Utensils Approved and in Good Repair <br /> OBSERVATIONS:2 D True freezer by the cooking area, has ice build up underneath the compressor and on the top shelf. <br /> Fix unit in 1 week. <br /> CALCODE DESCRIPTION:All utensils and equipment shall be fully operative and in good repair. (114175).All utensils and equipment <br /> shall be approved,installed properly,and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5, <br /> 114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182) <br /> #38 Approved/Sufficient Ventilation and Lighting <br /> OBSERVATIONS:Light at the washing area is inadequate. Replace light tubes to provide adequate light in 1 week. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by <br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation <br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft,or a <br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas <br /> to facilitate cleaning and inspection.Light fixtures in areas where open food is stored, served,prepared,and where utensils are washed <br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:Pipe, draining the ice maker in the floor sink, is lacking air gap. Provide air gap minimum 1 inch off the <br /> floor sink in 1 week. <br /> CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances, shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> FA0012187 PR0515493 SCO01 05/18/2021 <br /> EHD 16-23 Rev.09/16/2020 Page 2 of 3 Food Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />