Laserfiche WebLink
SAN <br /> J U I Environmental It t <br /> It Jasjit Kang , REHS , Director <br /> ' PI <br /> rW Muniappa Naidu , REHS , Assistant Director <br /> • ,, ft" Dt . <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Melissa Nissim , REHS <br /> Steven Shih , REHS <br /> October 21 , 2021 <br /> MATT THOMAS <br /> CGRS INC <br /> 5444 DRY CREEK ROAD <br /> SACRAMENTO , CA 95838 <br /> Re : MORADA CHEVRON FAST N EASY #60 AMENDED - SR0084153 <br /> 10878 N HIGHWAY 99 E <br /> STOCKTON , CA 95212 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Repair the 91 /diesel tank secondary <br /> ® Replace (2) turbine sumps in both 91 sumps <br /> ® Install new penetration fittings in 91 sumps <br /> • Install new flex lines in 91 sumps <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department, the San Joaquin Valley Air Pollution Control District , and the San <br /> Joaquin County Community Development Department for any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust(d. siclov . ora to arrange the following appointments (a 48 - hour <br /> notice is required for inspection appointments) . Please be aware that inspections for emergency <br /> work must be scheduled within five days of permit approval . <br /> a) Primary piping soap test of all piping and penetrations ( product) within the 91 sumps : One <br /> hour pneumatic pressure test at 110 % of operating pressure , or 40 psi , whichever is greater. <br /> b) Secondary piping soap test of all piping and penetrations (product) within the 91 sumps : <br /> One- hour pressure test at the manufacturers recommended specification . <br /> c) Secondary piping slope , at 1 / 8 inch per foot or greater, to a containment sump with an <br /> audible/visual alarm . <br /> d ) Verification of all pipe setbacks and burial depth according to the manufacturer' s installation <br /> Instructions . Verification of appropriate backfill . <br /> e) Integrity testing on the two 91 turbine sumps per the manufacturer' s installation instructions . <br /> f) A secondary containment test must be performed on the 91 /diesel tank once concrete is <br /> poured in accordance with the manufacturer' s guidelines . <br /> g ) Leak detector test: Leak detector must be tested to confirm that the device can detect a leak <br /> of 3 gallons per hour at 10 psi . Leak detector monitored line volumes shall be appropriate <br /> for the make and model of the installed leak detectors , and shall be verified at the time of <br /> installation . <br /> h ) If concrete is broken near the 87 tank , 87 and diesel sumps , or 87 and diesel pipe , a <br /> secondary containment test must be performed on the affected components once concrete <br /> is poured in accordance with the manufacturer' s guidelines . <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468-3420 F 209 464 -0138 www . sjgov . org/ehd <br />