My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
907
>
2900 - Site Mitigation Program
>
PR0091911
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2021 6:45:20 PM
Creation date
5/19/2021 4:32:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0091911
PE
2950
FACILITY_ID
FA0004088
FACILITY_NAME
JOE BRYSON HEATING AND A/C
STREET_NUMBER
907
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15133505
CURRENT_STATUS
02
SITE_LOCATION
907 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
k" KLEINFELDER <br /> SOH, ASSESSMENT WORK PLAN <br /> JOE BRYSON HEATING <br /> 907 SOUTH WH,SON WAY <br /> STOCKTON, CALIFORNIA <br /> 24-220222-A00 <br /> December 23, 1992 D E C 2 8 1992 <br /> INTRODUCTION y w �-NTAL HEALTH <br /> PttiMIT/SERVICES <br /> The site is located at 907 South Wilson Way in Stockton, California. In 1991, two <br /> underground gasoline storage tanks were removed from a common excavation at the facility. <br /> Due to allegations regarding the integrity of the tank removal contractor and the lack of <br /> adequate notification to SJCEHD of the removal, the results of the verification samples were <br /> not accepted by SJCEHD. To consider site closure, SJCEHD is requiring additional <br /> verification sampling. SJCEHD requested a single boring be advanced through the backfilled <br /> excavation. <br /> Kleinfelder has been retained by Joe Bryson Heating and Air Conditioning to implement the <br /> scope of work requested by SJCEHD. <br /> SCOPE OF SERVICES <br /> Task 1 - Drilling and Sampling of One Boring <br /> One boring will be drilled near the center of the previous excavation. The boring will be <br /> drilled to a depth of approximately 35 feet. Kleinfelder assumes that the original excavation <br /> depth was less than 35 feet. Kleinfelder assumes that the original excavation depth was less <br /> than 35 feet. The soil boring will be advanced using a truck-mounted drill rig equipped with <br /> 6-inch hollow stem augers. The boring will be drilled, logged, and sampled following the <br /> protocol described in Attachment A, Sections A-2.1 through A-2.4, and closed as described in <br /> Section A-2.7. <br /> Task 2 - Laboratory Analysis <br /> Two soil samples from the boring will be selected for laboratory analysis. The samples will be <br /> selected based on field observations, qualitative screening results, and the objectives of the <br /> assessment. Both soil samples will be submitted to a laboratory certified by the State of <br /> California Department of Toxic Substances Control (DTSC) for the proposed analyses. The <br /> samples will be analyzed for: <br /> ► Purgeable total petroleum hydrocarbons (EPA Method 8015M/5030) <br /> ► Benzene, toluene, ethylbenzene and xylenes (BTEX) (EPA Method 8020) <br /> ► Total lead (EPA Method 7420) <br /> ► Ethylene dibromide (EDB) (EPA Method 8010) <br /> FWP2-92-26 Page 1 of 3 24-220222-A00 <br /> Copyright 1992 Kleinfelder, Inc. <br />