My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2022 8:36:43 AM
Creation date
5/20/2021 11:26:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
SINCLAIR/DINO MART
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
26 ,2f Environmental Health Department <br /> SAN JOAQUIN <br /> CCU l , jIY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : TDe: <br /> AM PM HAMMER/ 15 FOOD #83113 3250 W HAMMER LN , STOCKTON y 26 , 2020 <br /> UST System Observations <br /> 311 HSC 25291 (b) Monitoring system incapable of detecting leak into secondary containment (pre-Jul 2003) ❑ V ❑ R ❑ COS <br /> 312 HSC 25290.2(d) Monitoring system incapable of detecting entry into secondary containment (Jul 2003-Jun 2004) ❑ V o R ❑ COS <br /> 313 HSC 25290. 1 (d) Monitoring system incapable of detecting entry into secondary containment (post-Jul 2004) ❑ V ❑ R o COS <br /> 314 CCR 2631 (g), 2632(c) Failure to continuously monitor interstitial space with audible-visual alarm system (pre-Jul 2004) ❑ V ❑ R ❑ COS <br /> (2) <br /> 315 HSC 25290. 1 (e) Failure to maintain interstitial space to detect leaks before release to environment (post-Jul 2004) ❑ V ❑ R ❑ COS <br /> r316 CCR 26361 2643(c)(1 ) , Failure to install a line leak detector ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 317 CCR 2636(f)(2) Failure of the line leak detector to detect a 3.0 gph leak at 10 psi and restrict or shut off flow ❑ V ❑ R ii COS <br /> 318 CCR 26351 2637. 11 Failed to meet spill container requirements ❑ V ❑ R ❑ COS <br /> 2665$ 2712 <br /> 319 CCR 2635, 2637.2, Failure to comply with overfill prevention equipment requirements ❑ V ❑ R ❑ COS <br /> 2665, 2712 <br /> 320 CCR 2635(c)(1 ) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> 321 HSC 25299(a)(9) Leak detection equipment disabled or tampered with o V ❑ R ❑ COS <br /> 322 CCR 271711 (g) Removed, defaced, altered, or otherwise tampered with red tag ❑ V ❑ R in COS <br /> 323 CCR 2717. 1 (0; HSC Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST ❑ V ❑ R ❑ COS <br /> 25292.3(c) <br /> 324 HSC 25292.3(c)(1 )(C) Allowed dispensing from a UST that has a red tag affixed to the fill pipe ❑ V ❑ R ❑ COS <br /> 325 CCR 2635, 2636(b), Failure to comply with the cathodic protection system requirements ❑ V ❑ R ❑ COS <br /> 2662, 2712 <br /> 326 CCR 2631 (b&d), Primary and/or secondary containment not constructed in accordance with the established standards ❑ V ❑ R ❑ COS <br /> 2666(b&e) <br /> 327 CCR 2638(a), 26410) Leak detection equipment not installed/calibrated/operated/maintained per manufacturer instructions ❑ V o R ❑ COS <br /> 328 CCR 2630, 2632, 2643, Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V ❑ R ❑ COS <br /> 2644. 1 <br /> 329 CCR 2631 . 1 , 2660(m) UST system not compatible with the substance stored ❑ V ❑ R ❑ COS <br /> 330 CCR 2636(f), 2666(c) , Failure of emergency generator line leak detector to restrict or shut off flow or trigger an alarm ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 331 HSC 25281 .6(a) Failure of unburied below-grade emergency generator system to meet exemption conditions ❑ V ❑ R ❑ COS <br /> 332 HSC 25283.5(a) Failure of unburied below-grade UST system to meet exemption conditions ❑ V ❑ R ❑ COS <br /> 333 CCR 2666(b)(2) Failure to upgrade single-walled pipe to double-walled interstitially monitored pipe when repaired ❑ V ❑ R ❑ COS <br /> 334 CCR 2670(b)(e)(f), Failure to comply with temporary closure requirements ❑ V ❑ R ❑ COS <br /> 2671 <br /> 335 HSC 25298; CCR 2670, Failure to comply with all permanent closure requirements ❑ V ❑ R ❑ COS <br /> 2672 <br /> 336 CCR 2638(f), 2641 (i) Failure to affix a tag/sticker on each monitoring equipment certified , repaired , or replaced ❑ V ❑ R ❑ COS <br /> Single -Walled Non -Pressurized Piping <br /> 401 CCR 2636(a)(3), Safe suction piping not properly sloped or check valve incorrectly located ❑ V ❑ R ❑ COS <br /> 2641 (b) <br /> 402 CCR 2643(d) Failure to conduct monitoring and maintain records for single-walled conventional suction (pre-1984) ❑ V ❑ R ❑ COS <br /> 403 CCR 2643(d), 2661 (f) Failure to conduct 0. 1 gph integrity test for single-walled conventional suction systems (pre-1984) ❑ V ❑ R ❑ COS <br /> FA0001877 PRO232224 SC001 05/26/2020 <br /> EHD 23-01 Rev. 9/16/2020 Page 3 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468-3420 F 209 464- 0138 1 www . sjgov . org/ EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.