My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3250
>
2300 - Underground Storage Tank Program
>
PR0232224
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2022 8:36:43 AM
Creation date
5/20/2021 11:26:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0232224
PE
2361
FACILITY_ID
FA0001877
FACILITY_NAME
SINCLAIR/DINO MART
STREET_NUMBER
3250
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
08240009
CURRENT_STATUS
01
SITE_LOCATION
3250 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OS126 ( 2 ` Environmental Health Department <br /> SAN JOAQUIN <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date: <br /> AM PM HAMMER/15 FOOD #83113 1 3250 W HAMMER LN , STOCKTON May 26 , 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 208 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days . <br /> OBSERVATION : The designated operator failed to check and note all required items on the visual inspection <br /> reports . The incorrect and missing information included the following from the inspection reports : <br /> - The 10/15/2019 , 11 / 13/2019 and 4/ 1 /2020 DO reports did not include the date signed by the ownner/operator <br /> -The 01 /8/2020 , 2/5/2020 , 7/25/2019 , 8/20/2019 and 9/18/2019 DO reports did not include the owner/operator <br /> name . <br /> REGULATION GUIDANCE : During the visual inspection , the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION : Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports . <br /> This is a minor violation . <br /> 210 CCR 2715 (c) No employee present that were trained in the operation and maintenance of the UST system by a DO . <br /> OBSERVATION : The designated operator employee training for Sally Moreno was not performed and NOT <br /> CURRENT. <br /> REGULATION GUIDANCE : The designated operator shall train facility employees in the proper operation and <br /> maintenance of the UST system at least once every 12 months. The training shall be conducted before the <br /> individual performs the duties of a facility employees . The training shall include , but is not limited to: <br /> 1 . Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2 . Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3 . Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4 . Name of the contact person (s) for emergencies and monitoring equipment alarms <br /> Initial training shall also include a site-specific practical demonstration that provides both sharing information and <br /> evaluating knowledge for responding to emergencies , leak detection , monitoring alarms, spills and overfills . At least <br /> one of the facility employees present during operating hours shall have current training . <br /> CORRECTIVE ACTION : Ensure that employees have been trained by the designated operator, maintain the list on <br /> site , and submit a copy of the training records to the EHD . <br /> This is a minor violation . <br /> Overall Inspection Comments : <br /> An inspection report was provided to the facility operator on the day of inspection . The report was amended <br /> and replaces the initial report . <br /> " Violation #204 ( now 205) has been removed . <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation , and any supporting <br /> ii <br /> paperwork , within 30 days of receiving the amended inspection report . <br /> i <br /> FA0001877 PR0232224 SC001 05/26/2020 <br /> EHD 23-01 Rev. 9/16/2020 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjgov. org/EHD <br />
The URL can be used to link to this page