Laserfiche WebLink
°u'"c <br /> 0�2 Environmental Health Department <br /> SAN�IOAQUIN <br /> COUNTY Jasjit Kang, REHS, Director <br /> c —gyp Muniappa Naidu,REHS,Assistant Director <br /> 9CiFOi+a� Gf20tl1255 9fOwS here. PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco,REHS,RDI <br /> Willy Ng,REHS <br /> Melissa Nissim,REHS <br /> Steven Shih,REHS <br /> April 26, 2021 <br /> Central Valley Baptist Church <br /> Parry Dalzell <br /> 10948 S. Airport Road <br /> Manteca, CA 95336 <br /> RE: Onsite Wastewater Treatment System <br /> 10948 S. Airport Road, Manteca <br /> APN 204-020-04, SR0083515 <br /> The San Joaquin County Environmental Health Department (EHD) has reviewed Onsite Wastewater <br /> Treatment System (OWTS) for the above noted location, and has the following comments for your <br /> consideration. <br /> Based on the information provided, the EHD concurs with the proposed engineer design septic system with <br /> the following conditions: <br /> 1. Obtain Engineer Designed System — Commercial application prior to installation of system. The fee is <br /> based on the current schedule at the time of payment. <br /> 2. Obtain an annual package treatment facility permit to operate after the installation permit is finalized. <br /> As part of package treatment, EHD shall require flow rate and monthly grab sample of total nitrogen <br /> and biochemical oxygen demand (BOD) from Inffluent and Effluent. The results are to be submitted to <br /> EHD on quarterly basis. EHD may reduce the monitoring frequency based on the monitoring result <br /> after two years. <br /> 3. EHD may require the service & maintenance to be continued on an ongoing basis after the two initial <br /> years of service by Superior On-Site Solutions based on the consistency of monitoring results. <br /> 4. The sizing of the OWTS filter bed shall conform to San Joaquin County onsite wastewater treatment <br /> system standard. The filter bed shall contain minimum of 12 inches of rocks below the drainpipe and 2 <br /> inches above the pipe. The rocks used for filter bed shall be one (1) inch to two and one-half (2 '/2) <br /> inches in diameter. <br /> 5. Visual and audio alarm is required and verified by EHD inspector. <br /> Note: It is the owner responsibility to ensure the system meets all requirements set forth in the design in <br /> conformity with San Joaquin County (OWTS) Standard. <br /> If you have any questions please contact Naseem Ahmed, Senor Registered Environmental Health Specialist, <br /> at nahmed@sjgov.org or (209) 616-3018. <br /> Steven Shih, REHS <br /> Program Coordinator <br /> c: Rick McCauley with R&R Consulting 3609 Bradshaw Rd #311, Sacramento, CA 95826 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/ehd <br />