My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEBER
>
448
>
2900 - Site Mitigation Program
>
PR0009038
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2021 6:01:31 PM
Creation date
5/20/2021 2:19:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0009038
PE
2960
FACILITY_ID
FA0004035
FACILITY_NAME
STOCKTON REDEVELOPMENT AGENCY
STREET_NUMBER
448
Direction
W
STREET_NAME
WEBER
STREET_TYPE
AVE
City
STOCKTON
Zip
95203
APN
13726005
CURRENT_STATUS
02
SITE_LOCATION
448 W WEBER AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1874
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 5 of 8 <br /> r vironmental Glossary of Terms and Qualifiersct <br /> LO <br /> Work Order Number: 12-10-1472 <br /> Qualifier Definition <br /> See applicable analysis comment. <br /> < Less than the indicated value. <br /> > Greater than the indicated value. <br /> 1 Surrogate compound recovery was out of control due to a required sample dilution. Therefore, the sample <br /> data was reported without further clarification. <br /> 2 Surrogate compound recovery was out of control due to matrix interference. The associated method blank <br /> surrogate spike compound was in control and, therefore, the sample data was reported without further <br /> clarification. <br /> 3 Recovery of the Matrix Spike(MS)or Matrix Spike Duplicate(MSD)compound was out of control due to <br /> matrix interference. The associated LCS and/or LCSD was in control and, therefore, the sample data was <br /> reported without further clarification. <br /> 4 The MS/MSD RPD was out of control due to matrix interference. The LCS/LCSD RPD was in control and, <br /> therefore, the sample data was reported without further clarification. <br /> 5 The PDS/PDSD or PES/PESD associated with this batch of samples was out of control due to a matrix <br /> interference effect. The associated batch LCS/LCSD was in control and, hence, the associated sample <br /> data was reported without further clarification. <br /> 6 Surrogate recovery below the acceptance limit. <br /> 7 Surrogate recovery above the acceptance limit. <br /> B Analyte was present in the associated method blank. <br /> BU Sample analyzed after holding time expired. <br /> E Concentration exceeds the calibration range. <br /> ET Sample was extracted past end of recommended max. holding time. <br /> HD The chromatographic pattern was inconsistent with the profile of the reference fuel standard. <br /> HDH The sample chromatographic pattern for TPH matches the chromatographic pattern of the specified <br /> standard but heavier hydrocarbons were also present(or detected). <br /> HDL The sample chromatographic pattern for TPH matches the chromatographic pattern of the specified <br /> standard but lighter hydrocarbons were also present(or detected). 0 <br /> J Analyte was detected at a concentration below the reporting limit and above the laboratory method <br /> detection limit. Reported value is estimated. <br /> ME LCS/LCSD Recovery Percentage is within Marginal Exceedance(ME)Control Limit range. <br /> ND Parameter not detected at the indicated reporting limit. <br /> Q Spike recovery and RPD control limits do not apply resulting from the parameter concentration in the <br /> sample exceeding the spike concentration by a factor of four or greater. <br /> SG The sample extract was subjected to Silica Gel treatment prior to analysis. <br /> X % Recovery and/or RPD out-of-range. <br /> Z Analyte presence was not confirmed by second column or GC/MS analysis. <br /> Solid - Unless otherwise indicated, solid sample data is reported on a wet weight basis, not corrected for <br /> % moisture. All QC results are reported on a wet weight basis. <br /> MPN - Most Probable Number <br /> 7440 Lincoln Way, Garden Grove, CA 92841-1427 • TEL:(714) 895-5494 FAX: (714)894-7501 <br />
The URL can be used to link to this page
Your browser does not support the video tag.