Laserfiche WebLink
Y! �Z SAN JOAQUIN Environmental Health Department <br /> pP... ....... C <br /> ' .:O . <br /> Q. Jas it Kang , REHS , Director <br /> "` C_ - `� COUNTY 1 9 <br /> LL cgtlFoa Greatness grows here . Muniappa Naidu , REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Melissa Nissim , REHS <br /> Steven Shih , REHS <br /> May 13 , 2021 <br /> DEBORAHJONES <br /> ELITE IV CONTRACTORS <br /> 2535 WIGWAN DR <br /> STOCKTON , CA 95205 <br /> Re : QUIK STOP MARKET # 124 SR0083685 <br /> 505 N MAIN ST , MANTECA , CA 95336 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Replace dispensers with conversion frame installation <br /> • Cold start the monitoring panel <br /> • Convert the existing 89 - octane tank to 87 - octane <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust ( slgov . org to arrange the following inspection appointments <br /> ( a 48 - hour notice is required for inspection appointments ) . <br /> a . Sensor functionality : Functionality of the monitoring system must be verified to ensure that <br /> monitoring has been restored to meet the requirements of Title 23 California Code of <br /> Regulations and the Health & Safety Code . A copy of the alarm history shall be printed <br /> prior to performing the cold start of the monitoring panel , and made available at the time of <br /> EHD inspection . <br /> b . Verification of the dispenser footprints contained by the under dispenser containment <br /> sumps ( UDCs ) . Any potential leaks from piping and fuel filters must drain directly into <br /> UDCs . <br /> c . Visual inspection of the piping within the dispensers <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 -3420 1 F 209 464 -0138 1 www . sjgov. org/ehd <br />